TEF 4500 - 1

V%*«* • *. *. HAlbECK UtirtT&CxJNTfiQL. SYSTEM ' TECHNICAL DATA Required incoming power: Control system for decklights, floodlights and windsock lights The TEF 4500 Commander Utility Helideck Lights Control System (HLCS) is a complete control system for all helideck lights. Based upon the Commander Utility technology, this control system allows the control panel to be installed in the bridge or radio equipment room, while the enclosure with all other necessary components may be installed further away. Between the two a simple Cat 3 ++ cable ensures that the industry-proven RS-485 network provides a reliable two-way communication. The control panel includes 5 buttons that control the perimeter lights, floodlights and windsock lights. In addition the panel includes a main power button for the entire system, an alarm acknowledge button and a button to dim the backlight. Three spare buttons are available, which may be used if additional components are installed in the control enclosure. Customer- specific text on buttons is op- Among the unique features of the system is the capability of con- necting several control panels to the network, enabling full control and monitoring from several locations. Optionally a gateway may be installed to provide two-way communications to an external control system (NMEA-0183 compliant/proprietary), as well as three addi- tional contactors and circuit breakers to make full use of the 8 con- trol buttons at the control panel. TECHNICAL DESCRIPTION The HLCS features one alarm input, and the alarm signal handling towards the bridge follows the Naut-OSV standards. Once an alarm is registred in the HLCS (e.g. a tripped circuit breaker), the audible buzzer in the control panel will activate and a red led will flash. At the same time the Bridge Alarm Relay activates, providing a volt-free alarm signal that may be connected to the bridge alarm system. The alarm signal may be silenced in two ways; either by pressing the acknowledge button at the control panel or by providing a 24VDC signal to the Bridge Alarm Acknowledge input at the control elec- tronics inside the enclosure. After the acknowledge signal is pro- vided, a second relay, the Bridge Alarm Reset relay, is activated for a period of one second. This relay may be used to silence the alarm in the bridge alarm system in case the alarm was acknowledged at the control panel. The Bridge Alarm Relay will stay activated until the reason for the alarm is removed. Ready for installation; comes complete with control panel and enclosure with 5 outgoing circuits, B10A. Expandable to 8 cir- Control panel may be mounted far away from the enclosure. Up to 7 control panels may be connected to the network, ena- bling control capabilities from each location. Common alarm on circuit breakers Naut-OSV alarm signalling towards brigde alarm handling sys- Tranberg AS | P.O. Box 8033 | N-4068 Stavanger | Norway | Tel.: (47)51 57 89 00 | Fax.: (47)51 57 89 50 E-mail: info@tranberg.com | www.tranberg.com Tranberg Systems | Hjulmagervej 15C | 7100 Vejle | Denmark | Tel.: (45) 75 85 83 80 E-mail: mail@tranbergsystems.com | www.tranbergsystems.com

Abrir o catálogo na página 1
TEF 4500 - 2

TEF 4500 COMMANDER UTILITY, HELIDECK LIGHTS CONTROL SYSTEM DESCRIPTION Part No. TEF 4500 Commander Utility, Helideck Lights Control System 4500103 Additional Control Panel 4500703 DIMENSIONS Panel outer dimensions Perimeter Lights 1 Panel cut-out dimensions Control cabinet Windsock Perimeter Lights 2 Floodlights 1 Floodlights 2 Backlight Level Alarm Acknowledge Made in Norway ++ - - Power MODE 24VDC Rx Tx Status Fault Address -Con3 External Alarm PANEL Power Network Error commander series 4500801 Relay Output Module 24 x 1NO Outputs Nominal current: 500mA 250VAC. Max. fuse 2A Control...

Abrir o catálogo na página 2

Todos os catálogos e folhetos TRANBERG

  1. TEF 2613

    2 Páginas

  2. TEF 2561

    2 Páginas

  3. TEF 4500

    2 Páginas

  4. TEF 2457

    2 Páginas

  5. TEF 2502

    2 Páginas

  6. TEF 2940

    2 Páginas

  7. TRANBERG

    28 Páginas

  8. TEF 2898

    2 Páginas

  9. TEF 2850

    2 Páginas

  10. TEF 2870

    2 Páginas

  11. TEF 4720

    2 Páginas

  12. TEF 1058 2508

    2 Páginas

  13. TEF 1058 1526

    2 Páginas

  14. TEF 1058 1506

    2 Páginas

  15. TEF 1058 1006

    2 Páginas

  16. TEF 1058 0506

    2 Páginas

  17. TEF 4740

    2 Páginas

  18. TEF 4722

    2 Páginas

  19. TEF 1104

    2 Páginas

  20. HML-ISO 35

    2 Páginas

  21. TEF 2620/2630

    2 Páginas

  22. TEF 2614

    2 Páginas

  23. TEF 2612

    2 Páginas

  24. TEF 2610

    2 Páginas

  25. TEF 4732

    2 Páginas

  26. TEF 4730

    2 Páginas

  27. TEF 1102

    2 Páginas

  28. TEF 2430X

    2 Páginas

  29. TEF 2920

    2 Páginas

  30. TEF 2438N

    2 Páginas

  31. TEF 2488

    2 Páginas

  32. TEF 2840

    2 Páginas

  33. Tyfon

    9 Páginas

  34. Winterization

    10 Páginas

  35. Obstruction lights

    10 Páginas

  36. Searchlightsl

    10 Páginas