Technical data sheet LONOX UCC (Ultra Clean Combustion) System Energy and heat supply Chemical industry Refineries Food industry Building materials industry Steel and metal production Waste incineration And more … LONOX UCC (Ultra Clean Combustion) System The SAACKE LONOX UCC System complies with even the strictest The burner is designed for very low pressure resistance in the burn- international NO X Emission values, such as the 2017 limit values of er windbox, which is helpful for energy saving. It is equipped with 30 mg/m³ based on 3% dry O2 in Chinese urban areas. NO X reduction measures often lead to a high amount of excess O2 Suitable for different boiler design or a high level of CO. The reduction of these values often results in expensive and complex secondary measures or additional additives. The burner is suitable for different boiler design, different refrac- In contrast, the LONOX UCC System is based on SAACKE burner tory arrangement in firing chamber and different firing chamber technology that has proven its worth over decades. Thanks to a spe- geometry. Moreover the system is covered for different fuel gas cial, swirled flame geometry as well as a specially-engineered flame supply pressure. The burner draft loss of the combustion air is lower control, the burner avoids any necessary additional measures. This than 25 mbar (depending on the burner design). decreases fuel consumption as well as material costs and ensures compliance with emissions values, while maintaining a low flue gas recirculation rate of < 25%. Technical data: LONOX UCC System Applications Shell boilers and water-tube boilers in a capacity range of 10 - 80 t/h 8 - 64 MW (other sizes on request) All standard gaseous fuels < 30 mg/m³ (depends on boiler design) based on 3% O 2, dry Control range

Abrir o catálogo na página 1
LONOX UCC - 2

(SAACKE) Burner dimensions LONOX 320/640 780 Product notes D E F* G H J K M O P ^1 Extremely low NOX emissions (< 30 mg/m3) based on 3% O2, dry ^ Control range up to 1:10** ^ Excess air ratio under 15% at 100% MCR ^ Also suitable for extremely short furnaces ^ TUV-certified emissions without secondary measures or additional additives ^1 Suitable for shell boilers and water-tube boilers ^1 Reduced operating costs due to high-efficiency combustion technology and low auxiliary power requirement ^ Less maintenance time and exceptionally long life ^ Conforms with European and Chinese guidelines...

Abrir o catálogo na página 2

Todos os catálogos e folhetos SAACKE

  1. se@vis pro

    2 Páginas

  2. se@vis eco

    2 Páginas

  3. se@vis compact

    2 Páginas

  4. Coke Oven Gas

    2 Páginas

  5. Alternative Fuels

    2 Páginas

  6. Pulverized fuels

    2 Páginas

  7. SSB swirl burner

    2 Páginas

  8. EGCS-HM

    2 Páginas

  9. Spare parts

    2 Páginas

  10. Boiler Training

    2 Páginas

  11. Boiler Repair

    2 Páginas

  12. 03_PB_DDZ-M

    2 Páginas

  13. 05_PB_SKV-A

    2 Páginas

  14. FMB-VF-Lonox

    2 Páginas

  15. 14_PB_FMB-VD

    2 Páginas

  16. 19_PB_EME-VFT

    2 Páginas

  17. 08_PB_CMB-VS

    2 Páginas

Catálogos arquivados

  1. 09_PB_CMB-HF

    2 Páginas

  2. 20_PB_FMW-VD

    2 Páginas

  3. System_Progress

    32 Páginas