Flyer NORISYS 4 PMC - Power Management Controller
1 / 2Páginas

{{requestButtons}}

Excertos do catálogo

Flyer NORISYS 4 PMC - Power Management Controller - 1

Power Management Controller NORISYS 4 PMC - for Parallel Operation, Power Supply and System Protection The NORISYS 4 PMC - Power Management Controller - was deve- NORISYS 4 expansion unit, also used as an autarkic system loped as part of the NORISYS 4 control components in the auto- Optional expansion with NORISYS 4 modules mation platform. Optional connection of colour touch panel for observation and control purposes The power management unit is used as an independent control USB port for servicing purposes system with an optional colour touch panel and can be expan- RS-485 for NORISYS 4 ExtBus communication ded to form a high-level system with further components of the Generator set control with automatic start/stop function Parallel and isolated operation Automatic synchronisation Generator protection functions, 3-phase cessor with DSP functionality. In its basic version, the PMC is used Power supply protection function, 3-phase to switch generators to the power grid and is also suitable for use in stand-by power supply facilities. The system is designed to be used for isolated and parallel operation. An automatic start and synchronisation function is additionally implemented to accelerate the generator, set to nominal speed as well as to synchronise and close the power circuit breaker. The power requirements are defined by a higher-level system. An automatic facility that controls load balancing, opening of the power circuit breaker and stopping of the propulsion system is also integrated for the purpose of shutting down the generator. The Power Management Controller is equipped with an integrated power supply and system protection function.

Abrir o catálogo na página 1
Flyer NORISYS 4 PMC - Power Management Controller - 2

Discrete Signals Discrete Signals Discrete Signals NORISYS 4 PMC - Inputs J3 x system voltage (up to 385 V AC) J3 x generator voltage (up to 385 V AC) J3 x generator current transformer up to 5A AC x speed pick-up J2 x analogue input (0 ... 20 mA, 4 ... 20 mA, 0 ... 10 V, +10 V ... -10 V) J1 x battery voltage (32 V) J1 x oxygen sensor voltage for system with mixture control J1 x potentiometer J10 x digital input, 1-pole NORISYS 4 PMC - Outputs J2 x analogue output (0 ... 20 mA, 4 ... 20 mA, 0 ... 5 V, +/-5 V, 0 ... 10 V, +/-10 V) J10 x digital output, 1-pole NORISYS 4 PMC - Communication...

Abrir o catálogo na página 2

Todos os catálogos e folhetos NORIS Group GmbH

  1. Datasheet TAV131

    3 Páginas

  2. Datenblatt VFS5

    2 Páginas

  3. Datasheet PAx9

    6 Páginas

  4. Datasheet RG5

    2 Páginas

  5. Datasheet VFW5

    2 Páginas

  6. Datasheet VD61

    6 Páginas

  7. Datasheet FA13

    14 Páginas

  8. Datasheet NIQ31

    16 Páginas

  9. Datasheet FA54

    11 Páginas

  10. NORIS Brochure

    15 Páginas

  11. Datasheet EOT

    6 Páginas

  12. Datasheet DWA

    4 Páginas

  13. Datasheet TP23

    4 Páginas

  14. Datasheet VF5

    2 Páginas

  15. Datasheet RFW5

    2 Páginas

  16. Datasheet RTK5

    2 Páginas

  17. Datasheet RFJ5

    2 Páginas

  18. Datasheet VTK5

    2 Páginas

  19. Datasheet RF5

    2 Páginas

  20. Datasheet RI5

    2 Páginas

  21. Datasheet RFG5

    2 Páginas

  22. Datasheet VPT5

    2 Páginas

  23. Datasheet RH5

    2 Páginas

  24. Datasheet VFS5

    2 Páginas

  25. Datasheet RH41M

    2 Páginas

  26. Datasheet RW5

    2 Páginas

  27. Datasheet VMP70

    3 Páginas

  28. Datasheet VP5

    2 Páginas

  29. Datasheet NADS3

    2 Páginas

  30. Datasheet NAD2

    2 Páginas

  31. Datasheet NAD1

    2 Páginas

  32. Flyer NORISYS 4

    2 Páginas

Catálogos arquivados

  1. Datasheet GE12

    2 Páginas

  2. Datasheet GE14

    2 Páginas