Excertos do catálogo

Input 12, 24 and 48 V ONS Range The inverters of the ONS range convert battery DC voltage into 230V/50 Hz AC current. The ONS digital sine wave technology reduces the number of components necessary and increases the equipments’ reliability. The ONS inverters deliver a sinusoidal wave identical to the mains supply and are suited to a wide range of industrial and marine applications. ■ Data processing: • Computing systems on board vehicles, • Navigation systems, • Automatic systems. ENAG S.A.S. - 31 rue Marcel Paul - Z.I. Kerdroniou Est - 29000 Quimper — FRANCE Tel:+ 33 2 98 55 51 99 — Fax :+ 33 2 98 55 51 67 - E-mail: contact@pnag.fr - Site : www.enag.fr -i
Abrir o catálogo na página 1
■ Main technical specification ■ Advantages: Overload capacity for starting surge High efficiency - low stand - by consumption High reliability, limited size and weigh. Fuse integrated protection. Battery protection with stop on low voltage ■ Incoming power: 12 Vdc, 24 Vdc or 48 Vdc according to model Tolerance: -12% to +30% Reduced consumption offload. Minimum battery capacity (Ah) advised: 5x (Rated power (W)/Input voltage (V)). ■ Output: 230 Vac ± 5% single phase. Frequency: 50Hz ± 0,05 %. Sinewave. Distortion < 5% Continuous Cos max: 0.1-1 Rated power from 200VA to 3500VA according...
Abrir o catálogo na página 2Todos os catálogos e folhetos ENAG
-
ALT range – 72Vdc-300A
2 Páginas
-
ALT-ADT range – 28Vdc mobile
2 Páginas
-
PSEA-PBD range – 24/72/110V mobile
2 Páginas
-
Power supply – 230Vac – 500A mobile
2 Páginas
-
Power supply – 24Vdc – 265A mobile
2 Páginas
-
Power supply 24Vdc – 135A Rack
2 Páginas
-
BDB range – Mobile discharge
2 Páginas
-
BCD range – Mobile Charge/Discharge
2 Páginas
-
CDP range – Mobile Charge/Décharge
2 Páginas
-
DPF range – Mobile Discharge Bank
2 Páginas
-
Battery charger – 24V-135A – Rack
2 Páginas
-
Battery charger – 24V-265A – Mobile
2 Páginas
-
CD range – 24 to 110V – Mobile
2 Páginas
-
DC/DC CONVERTER – SD RANGE
2 Páginas
-
AXIAL AND CENTRIFUGAL FANS AC AND DC
8 Páginas
-
COMPRESSION PUMP UNIT AC OR DC
2 Páginas
-
DC/AC SINUS INVERTER – ONS RANGE
2 Páginas
-
MODULAR INVERTER – ONS-M RANGE
2 Páginas
-
RADIATOR – RAEL RANGE
2 Páginas
-
ADM-SB – C13100 range
4 Páginas
-
CDMV range – 24V – Single phase
2 Páginas
-
Fire and gas marine approval dampers
2 Páginas
-
Water separator
4 Páginas
-
RAEL range – 24V – 230/400Vac
2 Páginas
-
ONS-M range – AC/DC – Modular
2 Páginas
-
Compression pump unite AC or DC
2 Páginas
-
Propeller pitch indicator
2 Páginas
-
Marine Battery
2 Páginas
-
IP56 and IP68 Specifics motors
2 Páginas
-
CF range – 50/60Hz ou 60/50Hz
2 Páginas
-
SD range – 12/48/110V
2 Páginas
-
Battery monitor for JBNUM-II
2 Páginas
-
CRT range – 24/48/110V – Three phase
2 Páginas
-
CDT range – 24 to 110V – Mobile
2 Páginas
-
CDS4 H range
2 Páginas
-
CDS4 range – 12/24V
4 Páginas
-
CDS3 range – 24V – BV
2 Páginas
-
CDS3 range – 12/24/48V
2 Páginas
-
CDS range – 12/24V
2 Páginas
-
24Vdc alternator
2 Páginas
-
Shaft line alternator
1 Páginas
-
ADM-SB range – Marine
2 Páginas
-
ADM-SB range – AC/DC
4 Páginas
-
SQ range
2 Páginas
-
ALM-ALT range – AC/DC
2 Páginas
-
Grille pare-pluie marine
1 Páginas
-
DC/DC converters - SD Range
2 Páginas