CKP-Series
1 / 10Páginas

{{requestButtons}}

Excertos do catálogo

CKP-Series - 1

CKP-Series J1939 Customizable Keypads P ROD UC T WE BP A GE request sample, configure part, watch video Compliant with SAE J1939 CAN standards, the CKP-Series is a customizable membrane keypad featuring laser etched legends and up to three dimmable LED function lights per button, which also offer diagnostic feedback by blinking if there is a fault. With above and below panel sealing protection, the CKP-Series can be installed inside or outside the cab. Typical Applications ∙ Commercial Vehicles

Abrir o catálogo na página 1
CKP-Series - 2

CKP-Series - SAE J1939 CAN Keypad - Design Features Design Features LOW PROFILE DESIGN 0.57 inch [14.48 mm] thickness (see dimensional specs for more detail) Front View SEALING PROTECTION Fully sealed IP6K9K above panel One, two, or three LED Function Lights per button. Colors include Amber, Green, Red or Blue CUSTOMIZABLE ICONS Choose from our standard library of icons or use custom icons Back View SEALING PROTECTION Fully sealed IP6K8 below panel when connected Mates to the Deutsch DT-Series Connector MOUNTING STUDS OR WINGS Related Products Operator Control Module

Abrir o catálogo na página 2
CKP-Series - 3

Tech Specs General Illumination LED backlit icons and function lights. Up to 3 function lights per button. Dimmable illumination, controlled by CAN messages Connection / Wiring Deutsch DT-Series connector (See Dimensional Specs) The keypad passes SAE J1455 section 4.13.1 for power up, operating voltage, over voltage, reverse polarity, and short circuit IEC 60068-2-13 Soak: IEC 60068-2-78, 93% RH (±3%), 10 day cycle IEC 60068-2-30, test Db: Damp Heat cycle (12 hr. cycles for each variant) 6 cycles total Ingress Protection ISO 20653, IP6K9K, for above panel components of actual switch only....

Abrir o catálogo na página 3
CKP-Series - 4

Tech Specs Software Interface Integration Click below on integrating the CKP-Series into J1939 CAN network: www.carlingtech.com/sites/default/files/documents/ckp-series_interface.pdf Table A: Standard Illumination Type Table B: Working Current 2x2 12V, 10% Luminance *Manufacturer reserves the right to change product specification without prior notice.

Abrir o catálogo na página 4
CKP-Series - 5

Ordering Scheme Part 1: Keypad 7. FUNCTION LIGHT COLOR Landscape Portrait See Orientation Diagrams page Reverse Landscape Reverse Portrait 10. SOURCE ADDRESS The Source Address is a unique number (000-248) assigned to each node on a CAN network, and is determined based on the specific CAN architecture of each customer application. Part 2: Icon Artwork (Select 12 buttons for 2x6, 10 buttons for 2x5, 8 buttons for 2x4, 6 buttons for 2x3, and 4 buttons for 2x2.) Icon Code Icon Code 8. NON-ILLUMINATED IMAGE COLOR Icon Code Icon Code Icon Code Icon Code Icon Code Icon Code Icon Code Icon Code...

Abrir o catálogo na página 5
CKP-Series - 6

Dimensional Specs inches [millimeters] MATES TO THE DEUTSCH DT-SERIES CONNECTOR MATES TO THE DEUTSCH DT-SERIES CONNECTOR PANEL CUTOUT TOLERANCE .005[0.13], PANEL THICKNESS TO BE .080[2.03] MIN AND .130[3.30] MAX. PANEL CUTOUT TOLERANCE .005[0.13], PANEL THICKNESS TO BE .080[2.03] MIN AND .130[3.30] MAX. Notes: 1. Do not puncture or plug the vent *Manufacturer reserves the right to change product specification without prior notice.

Abrir o catálogo na página 6
CKP-Series - 7

Dimensional Specs inches [millimeters] 10-32 MOUNTING STUDS (2X) (MAX TIGHTENING TORQUE 30 INCH LBS) MATES TO THE DEUTSCH DT-SERIES CONNECTOR PANEL CUTOUT TOLERANCE .005[0.13], PANEL THICKNESS TO BE .050[1.27] MIN AND .300[7.62] MAX. Notes: 1. Do not puncture or plug the vent 10-32 MOUNTING STUDS (2X) (MAX TIGHTENING TORQUE 30 INCH LBS) *Manufacturer reserves the right to change product specification without prior notice. MATES TO THE DEUTSCH DT-SERIES CONNECTOR PANEL CUTOUT TOLERANCE .005[0.13], PANEL THICKNESS TO BE .050[1.27] MIN AND .300[7.62] MAX.

Abrir o catálogo na página 7
CKP-Series - 8

Dimensional Specs inches [millimeters] PANEL CUTOUT +/- .020 PANEL THICKNESS TO BE .050 MIN AND .300 MAX. CONNECTOR TO BE MATED TO DEUTSCH DT SERIES CONNECTOR 10-32 STUDS (MAX TIGHTENING TORQUE 30 IN LBS.) PIN OUT AS SHOWN BELOW FOR ALL CONFIGURATIONS (2x2, 2x3, 2x4, 2x5, and 2x6) NO. DESIGNATION 1 BATT + 2 CAN L 3 BATT 4 IGN_ON 5 CAN H 6 CAN SHIELD Orientation Diagrams Icon Artwork Button Number Layout A: Landscape *Manufacturer reserves the right to change product specification without prior notice.

Abrir o catálogo na página 8
CKP-Series - 9

Standard Legend Codes YK WATER PUMP ISO compliant symbols. Consult factory for custom legends.

Abrir o catálogo na página 9
CKP-Series - 10

Authorized Sales Representatives and Distributors Click on a region of the map below to find your local representatives and distributors or visit www.carlingtech.com/findarep. MIDDLE EAST ASIA-PACIFIC OCEANIA SOUTH AMERICA About Carling Founded in 1920, Carling Technologies is a leading manufacturer of electrical and electronic switches and assemblies, circuit breakers, electronic controls, power distribution units, and multiplexed power distribution systems. With six ISO9001 and IATF16949 registered manufacturing facilities and technical sales offices worldwide, Carling Technologies Sales,...

Abrir o catálogo na página 10

Todos os catálogos e folhetos Carling Technoligies

  1. BD1-Series

    5 Páginas

  2. CPV-Series

    6 Páginas

  3. PC-Series

    10 Páginas

  4. PB-Series

    10 Páginas

  5. CTB-Series

    3 Páginas

  6. CMB-Series

    5 Páginas

  7. CLB-Series

    5 Páginas

  8. C1005B-Series

    3 Páginas

  9. V-Series

    8 Páginas

  10. CSW-Series

    7 Páginas

  11. 4M-Series

    6 Páginas

  12. LW-Series

    5 Páginas

  13. LMR-Series

    3 Páginas

  14. LD-Series

    4 Páginas

  15. CKJ-Series

    7 Páginas

  16. CM-Series

    15 Páginas

  17. BD-Series

    8 Páginas

  18. VP-Series

    6 Páginas

  19. CLTM12-Series

    10 Páginas

  20. AV/AVH-Series

    6 Páginas

  21. W-SERIES

    10 Páginas

  22. HR-Series

    10 Páginas