Product Models: 23610-3003 (12V), 23610-3103 (24V) - MAXI PUPPY 3000
Features:
  • Continuous rated, heavy-duty pumps suitable for bilge and general purpose use.
  • Compliant with ISO 8846 MARINE (Ignition protection) and ISO 8849 MARINE (Bilge pump standard).
  • Handles small bilge debris effectively with a bronze body and flexible impeller design.
  • Simple design with fewer wearing parts.
  • Output: 44 liters per minute (9.5 UK gallons per minute) at a 3-meter (10-foot) head.
  • Self-priming capability up to 2.4 meters (8 feet).
Installation Instructions:
  • Mount on any flat surface in a dry, well-ventilated area with full service access.
  • If mounted vertically, ensure the motor is above the pump head.
  • Use provided rubber grommets to minimize vibration; avoid overtightening screws.
  • Secure 25mm (1”) ID hose to discharge ports or ½” BSP male threaded fittings with stainless steel hose clamps.
  • Use spiral reinforced hose or rigid/semi-rigid pipework compatible with the pumped liquid.
  • Keep pipe runs straight and short, avoiding obstructions.
  • Fit a strainer on the inlet hose to prevent large debris entry.
Wiring Instructions:
  • Make electrical connections in dry locations; seal connections in humid environments to prevent corrosion.
  • Protect the circuit with a correctly rated fuse or circuit breaker in the red positive (+) lead near the power source.
  • Connect the black motor wire to the negative (-) battery terminal.
  • Ensure voltage at motor terminals is not less than 10% below rated voltage at full load to avoid performance issues.
Warnings:
  • If the fuse fails repeatedly, do not use a heavier fuse or bridge terminals with metal; this may cause a fire hazard.
  • Marine pumps discharging overboard must be installed with discharge well above static and heeled waterlines.
  • Do not use Jabsco pumps for petrol or products with a flash point below 37°C (98°F) to avoid explosion or death.
Performance Data:
Total Head (m)Total Head (ft)Flow Rate (lpm)Flow Rate (UK gpm)
274510
413429
620388.4
826347.5
1033306.6
1239255.5

Performance is based on a new pump running water at 20°C with a fully charged battery.

See more

Catalog excerpts

23610 Technical Datasheet-1

MAXI PUPPY 3000MODELS: 23610-3003 12V 23610-3103 24V CCINSTALLATION INSTRUCTIONS: WARNING: If the fuse fails repeatedly do not fit a heavier fuse or bridge the fuse terminals with silver paper or metal wire. Failure to observe this instruction may result in a fire hazard due to overheating of cables. Continuous rated, heavy duty pumps for bilge and general purpose use. • ISO 8846 MARINE (Ignition protection). • ISO 8849 MARINE (Bilge pump standard). • Small bilge debris present no problem to these bronze bodied, flexible impeller pumps. • Simple design means fewer wearing parts. • 44 lpm (9.5 UK gpm) output @ 3m (10ft) head. • Self priming to 2.4m (8 ft). MAXI PUPPY 3000 PERFORMANCE Approximate performance for new pump, running water at 20°C with fully charged battery Jabsco Maxi Puppy 3000 can be mounted on any flat surface. Fit the pump in a dry, well ventilated position where there is full access for service. If installed in a vertical position the motor must be above the pump head. Use the rubber grommets provided to minimise vibration, do not overtighten the mounting screws. Secure 25mm (1”) id hose either direct to the discharge ports or to %” BSP male threaded fittings using stainless steel hose clamps. Use spiral reinforced hose (with a smooth internal bore) that will not collapse under suction, or rigid or semi rigid pipework systems. The pipework must be compatible with the liquid being pumped. Pipe runs should be kept as straight and short as possible, avoiding rising and dipping over obstructions. Fit a strainer on the inlet hose to prevent larger debris from entering the pump. WIRING INSTRUCTIONS Make all electrical connections in dry locations, connections in humid environments should be sealed to prevent corrosion. Protect the circuit with a correctly rated fuse or circuit breaker in the red positive (+) lead as close as possible to the power source. Connect the black motor wire to the negative (-) battery terminal. Inadequate voltage at the motor terminals when the pump is running (not less than 10% below rated voltage at full load) due to partially discharged batteries or insufficient cable size may result in blowing fuses, failure to start or poor pump performance. WARNING: Do not use any Jabsco pump for petrol, petroleum products or any products with a flash point below 37°C (98°F), explosion or death may occur. WARNING: All marine pumps discharging overboard must be installed with the overboard discharge well above both static and heeled waterlines.

 Open the catalog to page 1
23610 Technical Datasheet-2

* For longer installations, fit thicker cables MAXI PUPPY 3000 PARTS LIST KEY DESCRIPTION QUANTITY PART NUMBER 1 End Cover 1 9328-0200 6 Screw (pump to motor) 2 X3001-147F Jabsco, I Kondelin Road, Cape Ann Industrial Park, Glocester, MA 01930 Tel: +1 978 281 0440 Fax : +1 978 283 2619 YWrisn* A* p-MjcH d ihe ce-eer, «• and ■■ Mt« o> *>* eoromr Oll—fl u/t*ec1 10 the co<w/> ~*ranty tnt ferns trt contfKA* ot »le

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.