XIAM MEN LONAKO INDUSTRY & TRADE CO., LTD O Tel: +86-5 592-5689172 Fax +86-592-568917 Web: www.lo x: 73 onako.com Add: N307, Weiye Building, Ch Pioneering Pa Xiamen, Fujian361009, P.R.China W hina ark, LO ONAKO Navi O igation Safet Ligh n ty ht (Type:LNK-N NS-1T) OPE ERATION and MA N AINTENAN NCE INST TRUCTIO ONS Pr roduct Name Navigation Safety Lig e: ght Pr roduct Type: LNK-NS-1 : 1T Do ocument No LNK--OMo.: -NS-1T Ve ersion: Ef ffective Date December 30,2018 e: r
Open the catalog to page 1Operation and Maintenance Instruction LNK-OM-NS-1T/V2.0 SECTION III Installation Instructions 4 SECTION W Operation And Usage Instruction 8 SECTION V Service Life & Safety 9 SECTION M Repair AND Disposal Instructions 10 SECTION IX Packaging Informa tion 10 SECTION X Manufacturer Information 11
Open the catalog to page 2Operation and Maintenance Instruction LNK-OM-NS-1T/V2.0 SECTION ⅠPURPOSE The operation and maintenance instruction is used to guide users how to operate and maintain LNK-NS-1T Navigation safety light properly. It also has full instruction of the products` functions and specifications. LONAKO LNK-NS-1T navigation safety light is a standard navigation light and LONAKO LED positioning light combination product. It can be used as standard navigation light, anchor light and other usages such as obstacle light, indicating-position light, trouble indicating light, SOS signal light and emergency...
Open the catalog to page 3input wire Figure 2-1 Product Structure
Open the catalog to page 4Table 2-1 Technical parameter SECTION H Installation Instructions 3.1 Installation Limitation The LNK-NS-1T navigation safety light should be installed on top of the mast for ships( L<20 meters). Such as: yachts, fish ships, leisure ships, sailing ships etc. The light should be installed at direction of the wind fan downwards and vertical to water surface, the red light towards left of the ship, the green towards right of the ship, and white light straightly towards the back of the ship as Figure 3-1 shows. The light should also avoid from lightning stroke risks.
Open the catalog to page 5Operation and Maintenance Instruction LNK-OM-NS-1T/V2.0 Figure 3-1: Installation direction of the light The LNK-NS-1T navigation safety light should be installed on top of the ship`s mast in order to ensure its maximum visibility in all directions. And the solar panel should not block from the sunlight. 3.2.2 Based on the distance between the installation location of the light and the power supply on the ship, wiring arrangement should be operated by professional electrician, including connecting the extension wire to the input wire of the navigation safety light, and ensure the joint is...
Open the catalog to page 6Operatio and Mainten on nance Instruction LNK-OM-NS S-1T/V2.0 Anti bird thor rn Installing the light on the pipe: The bigge two clips are fit for 1.2~1.3 inch pipe. The tw smaller clips can be separate inserted into biggest e est e wo ely clips to become o unit bracket for 0.95~1.05 in pipe. The sm c one nch mallest clips can be separately inserted into the b biggest clips to b become one unit bracket fo 0.7~0.8 inch pipe. When inst or talling the light, user should choose the suitable clips according to the size of pipe. One biggest clip with four ho oles can be fixed with ligh in vertical...
Open the catalog to page 7Operatio and Mainten on nance Instruction LNK-OM-NS S-1T/V2.0 3.2.6 3 In order t avoid the bird standing on light and block th solar panel fr to ds he rom sunlight, on unit anti-bird thorn is packed together with light. the ne users should set the spring spike on the thorn as below Figure 3-2.1 . Then pe off the 3M tap on bottom of the thorn and s u es a eel pe f stick it on the to of the op li ight, which is jus on red circle p st position shown on Figure 3-2.2 to make sure av o voiding solar pan function zoom and light sens nel m sor. Fig gure 3-2.1 Anti-b thorn bird Figure 3-2 Anti-bird...
Open the catalog to page 8Operatio and Mainten on nance Instruction LNK-OM-NS S-1T/V2.0 SECTI ION Ⅳ OPE ERATION INST TRUCTION 4.1 After the nav 4 vigation safety lig installed, users should press “POWER ON/O ght s OFF” button at bo ottom of light to turn the power on before use. o r 4.2 The navigatio light and anc 4 on chor light are sup pplied by DC 8~ ~33V power. The can be contro ey olled by the switc ches on the ship control board. p The positioning li T ight functions ar powered by bu re uilt-in rechargea able lithium batte They are on off status origin ery. nally, and they ca only be activa an ated and...
Open the catalog to page 9Operation and Maintenance Instruction LNK-OM-NS-1T/V2.0 remote become weak, users should replace battery for the remote. The remote itself is not waterproofed. 4.7 Each remote matches the light it was packed with. But if the old remote is lost or broken, the user can just buy new remote to match the old light. The matching operation is as below: 4.7.1 First, use one hand to keep pressing “FUNCTION SWITCH” on remote and point the light; Second, use another hand to keep pressing “POWER ON/OFF” at the bottom of light to turn on the light. After two seconds, after the light have a very short...
Open the catalog to page 10Operation and Maintenance Instruction LNK-OM-NS-1T/V2.0 SECTION Ⅶ MAINTENANCE The LNK-NS-1T navigation safety light is maintenance free, but the following routine checks should be done: 7.1 Keep the original packaging of light well and do not put heavy goods on light during storage period. The Lithium Batteries of the lights must be recharged at least one time every 3 months during storage in order to ensure the products` lifespan. Every time when the light is stored over 3 months, users should take the lights and put them under sunlight to recharge the battery for at least 8 hours. Or...
Open the catalog to page 11Operation and Maintenance Instruction LNK-OM-NS-1T/V2.0 Figure 9-1 Single unit package box 9.2 Carton package: 15units per carton. The size of carton is 630*280*295mm. The volume is 0.05m³and gross weight is about 10kg. SECTION Ⅹ MANUFACTURER INFORMATION Company name: XIAMEN LONAKO INDUSTRY & TRADE CO., LTD. Add: N307, Weiye Building, China Pioneering Park, Xiamen, Fujian361009, China Tel:+86-592-5689172 Fax:+86-592-5689173 Email:info@lonako.com Web:www.lonako
Open the catalog to page 12All Xiamen Lonako Inc. catalogs and brochures
-
Lonako Brochure
24 Pages
-
2022 LONAKO brochure
20 Pages
-
LONAKO 2021 Brochure
26 Pages
-
LONAKO 2019 brochure
18 Pages
-
LED Positioning Lights
11 Pages
-
LNK-LB-01B LIFEBUOY LIGHT
8 Pages
-
LNK-UL IP68
7 Pages
-
LNK-WET-02
5 Pages
-
LNK-FL
6 Pages
-
LNK-LB-02B
4 Pages
-
LNK-PL-W
8 Pages
-
LNK-LR-03A
6 Pages
-
LNK-LJ-03A1&W
5 Pages