Motors | Automation | Energy | Transmission & Distribution | Coatings W60 Three-Phase Induction Motor NEMA
Open the catalog to page 1W60 - Three-Phase Induction Motor The WEG W60 motor line is designed for industrial applications such as compressors, pumps, fans and others, ensuring high performance and reliability even under the most severe operating conditions. Flexibility is the Key The W60 is available on three different configurations allowing it to be designed as an open, self ventilated (IC01, WP-II) motor, or an enclosed, air-air cooled (IC611, TEAAC) or air-water cooled (IC81W, TEWAC) motor. Compact Design With its compact design, lightweight components, reduced dimensions and footprint that saves valuable space on...
Open the catalog to page 2R ated output: 630 up to 4,250 kW (850 up to 5,700 HP) Number of poles: 2 up to 6 Frame sizes: IEC 450 up to 560 NEMA 70 up to 88) Voltage: 2,300 up to 10,000 V Frequency: 50 or 60 Hz Mounting: horizontal B earing type: ball bearings (sleeve bearings available) C ooling method: IC01, IC611 and IC81W (WP-II, TEAAC and TEWAC) Starting: DOL or VFD RTD Pt-100, two per phase RTD Pt-100, one per bearing Space heater 4140 alloy steel shaft Copper bars rotor H azardous area certification: A TEX / IECEx / INMETRO certified: JJ Ex nA IIC T3 Gc (non-sparking) JJ Ex tc IIIB T125 °C Dc (dust-ignition) JJ...
Open the catalog to page 3Components Design Noise Suppressors JJ Noise level reduction JJ Easy removal and assembly JJ Easy maintenance End Shields High quality cast iron JJ Reinforced structure JJ Bearings Ball bearings as standard JJ Sleeve bearings as optional JJ W60 - Three-Phase Induction Motor
Open the catalog to page 4Cooling System ■ Optimized heat exchanger ■ Increased mechanical strength Electrical Core ■ High quality lamination ■ Increased power density ratio ■ Smallest footprint area
Open the catalog to page 5Design Details Cooling System With a new and optimized concept for heat exchanging, the W60 allows three different configurations that suits all sort of applications: JJ IC01 (WP-II) JJ IC611 (TEAAC) JJ IC81W (TEWAC) Bearings Ball bearings are standard for the W60. Its compact design allows utilization of antifriction ball bearings where other motors can not. Sleeve bearings are also available when required. Frame Designed using the most advanced software, the W60 new frame design provides a solid structure that allows operation in the most severe environments, suitable for high impact and speed...
Open the catalog to page 6Electrical Data W60 / TEAAC / 60 Hz / 4160 V Full load torque (lbf.ft) Locked rotor torque LRT Locked rotor current LRC Allowable locked rotor time Weight (lb) (s) % of full load Sound dB (A) Power factor Full load current (A) Note: valid for motors operating with sine-wave power supply. W60 - Three-Phase Induction Motor
Open the catalog to page 7Electrical Data W60 / TEAAC / 60 Hz / 6600 V Full load torque (lbf.ft) Locked rotor torque LRT Locked rotor current LRC % of full load Sound dB (A) Note: valid for motors operating with sine-wave power supply. Allowable locked rotor time Weight (lb) (s) W60 - Three-Phase Induction Motor Power factor Full load current (A)
Open the catalog to page 8Electrical Data W60 / TEWAC / 60 Hz / 4160 V Locked rotor current LRC Locked rotor torque LRT Full load torque (lbf.ft) Allowable locked rotor time Weight (lb) (s) % of full load Sound dB (A) Power factor Full load current (A) Note: valid for motors operating with sine-wave power supply. W60 - Three-Phase Induction Motor
Open the catalog to page 9Electrical Data W60 / TEWAC / 60 Hz / 6600 V Locked rotor current LRC Locked rotor torque LRT Full load torque (lbf.ft) % of full load Sound dB (A) Note: valid for motors operating with sine-wave power supply. Allowable locked rotor time Weight (lb) (s) W60 - Three-Phase Induction Motor Power factor Full load current (A)
Open the catalog to page 10Electrical Data W60 / WP-II / 60 Hz / 4160 V Locked rotor current LRC Locked rotor torque LRT Full load torque (lbf.ft) Allowable locked rotor time Weight (lb) (s) % of full load Sound dB (A) Power factor Full load current (A) Note: valid for motors operating with sine-wave power supply. W60 - Three-Phase Induction Motor
Open the catalog to page 11Electrical Data W60 / WP-II / 60 Hz / 6600 V Locked rotor current LRC Locked rotor torque LRT Full load torque (lbf.ft) % of full load Sound dB (A) Note: valid for motors operating with sine-wave power supply. Allowable locked rotor time Weight (lb) (s) W60 - Three-Phase Induction Motor Power factor Full load current (A)
Open the catalog to page 12Mechanical Features W60 / TEAAC / Ball Bearings Shaft Extension - Drive End (in) W60 - Three-Phase Induction Motor
Open the catalog to page 13Mechanical Features W60 / TEWAC / Ball Bearings Shaft Extension - Drive End (in) W60 - Three-Phase Induction Motor
Open the catalog to page 14Mechanical Features W60 / WP-II / Ball Bearings Shaft Extension - Drive End (in) W60 - Three-Phase Induction Motor
Open the catalog to page 15WEG Worldwide Operations ARGENTINA San Francisco - Cordoba Phone: +54 3564 421484 [email protected] COLOMBIA San Cayetano - Bogota Phone: +57 1 4160166 [email protected] JAPAN Yokohama - Kanagawa Phone: +81 45 5503030 [email protected] SPAIN Coslada - Madrid Phone: +34 91 6553008 [email protected] Cordoba - Cordoba Phone: +54 351 4641366 [email protected] ECUADOR El Batan - Quito Phone: +593 2 5144339 [email protected] MALAYSIA Shah Alam - Selangor Phone: +60 3 78591626 [email protected] SINGAPORE Singapore Phone: +65 68589081 [email protected] FRANCE Saint-Quentin-Fallavier - Isère Phone:...