1. Catalogs
  2. Victron Energy
  3. Skylla-i Battery Charger 24V

Skylla-i Battery Charger 24V

Skylla-i Battery Charger 24V

Skylla-i Battery Charger 24V

Product catalog summary
Overview: The Skylla-i battery chargers by Victron Energy are designed to charge multiple battery banks with options for 1+1 or 3 outputs. They are rugged, flexible, and suitable for various environments and battery types, including lead-acid and Li-Ion.
Specifications:
  • Skylla-i (1+1): Two outputs, with the second output limited to 4 A for starter battery top-up.
  • Skylla-i (3): Three full current outputs for charging three battery banks.
  • Input Voltage: 230 VAC, range 185-265 VAC or 180-350 VDC.
  • Charge Voltage: Absorption at 28.8 VDC, float at 27.6 VDC, storage at 26.4 VDC.
  • Charge Current: Up to 100 A, with adaptive 7-stage algorithm.
  • Temperature Range: -20 to 60°C, with full output up to 40°C.
  • Protection: Against reverse polarity, short circuit, and over temperature.
Features:
  • Rugged Design: Aluminium epoxy powder-coated cases with drip shield and stainless steel fixings.
  • Flexible Configuration: CAN bus interface, rotary switch, DIP switches, and potentiometers for charge algorithm adaptation.
  • BatterySafe Mode: Prevents damage from excessive gassing by limiting voltage increase rate.
  • Storage Mode: Reduces float voltage to minimize gassing and corrosion, with weekly refresh to prevent stratification and sulphation.
  • Temperature Compensation: Adjusts charge voltage based on battery temperature.
  • Voltage Sense: Compensates for voltage loss due to cable resistance.
  • AC and DC Supply: Suitable for both AC-DC and DC-DC operation.
  • Power Supply Use: Can be used as a power supply with stabilized output voltage.
  • Li-Ion Ready: Supports simple on-off control or complete control via CAN bus.
Additional Components:
  • BMV 700 Battery Monitor: Advanced microprocessor control for battery voltage and charge/discharge current monitoring.
  • Skylla-i Control Panel: Provides remote control and monitoring, with input current adjustment and parameter changes.
Standards: Complies with safety and emission standards such as EN 60335-1, EN 55014-1, and others.
See more

Catalog excerpts

Skylla-i Battery Charger 24V-1

Skylla-i Battery Charger 24V www.victronenergy.com Li-Ion ready Skylla-i (1+1): two outputs to charge 2 battery banks The Skylla-i (1+1) features 2 isolated outputs. The second output, limited to approximately 4 A and with a slightly lower output voltage, is intended to top up a starter battery. Skylla-i (3): three full current outputs to charge 3 battery banks The Skylla-i (3) features 3 isolated outputs. All outputs can supply the full rated output current. Rugged Aluminium epoxy powder coated cases with drip shield and stainless steel fixings withstand the rigors of an adverse environment: heat, humidity and salt air. Circuit boards are protected with an acrylic coating for maximum corrosion resistance. Temperature sensors ensure that power components will always operate within specified limits, if needed by automatic reduction of output current under extreme environmental conditions. Flexible Next to a CAN bus (NMEA2000) interface, a rotary switch, DIP switches and potentiometers are available to adapt the charge algorithm to a particular battery and its conditions of use. Please refer to the manual for a complete overview of the possibilities. Important features: Skylla-i 24/100 (3) Synchronised parallel operation Several chargers can be synchronised with the CAN bus interface. This is achieved by simply interconnecting the chargers with RJ45 UTP-cables. Please see the manual for details. The right amount of charge for a lead-acid battery: variable absorption time When only shallow discharges occur the absorption time is kept short in order to prevent overcharging of the battery. After a deep discharge the absorption time is automatically increased to make sure that the battery is completely recharged. Preventing damage due to excessive gassing: the BatterySafe mode If, in order to quickly charge a battery, a high charge current in combination with a high absorption voltage has been chosen, the Skylla-i will prevent damage due to excessive gassing by automatically limiting the rate of voltage increase once the gassing voltage has been reached. Less maintenance and aging when the battery is not in use: the Storage mode The storage mode kicks in whenever the battery has not been subjected to discharge during 24 hours. In the storage mode float voltage is reduced to 2,2 V/cell (26,4 V for 24 V battery) to minimise gassing and corrosion of the positive plates. Once a week the voltage is raised back to the absorption level to ‘refresh’ the battery. This feature prevents stratification of the electrolyte and sulphation, a major cause of early battery failure. To increase battery life: temperature compensation Every Skylla-i comes with a battery temperature sensor. When connected, charge voltage will automatically decrease with increasing battery temperature. This feature is especially recommended for sealed lead-acid batteries and/or when important fluctuations of battery temperature are expected. Battery voltage sense In order to compensate for voltage loss due to cable resistance, the Skylla-i is provided with a voltage sense facility so that the battery always receives the correct charge voltage. Suitable for AC and DC supply (AC-DC and DC-DC operation) The chargers also accept a DC supply. Use as a power supply As a result of the perfectly stabilized output voltage, the Skylla-i can be used as a power supply if batteries or large buffer capacitors are not available. Li-Ion (LiFePO4) ready Simple charger on-off control can be implemented by connecting a relay or open collector optocoupler output from a Li-Ion BMS to the remote control port of the charger. Alternatively complete control of voltage and current can be achieved by connecting to the galvanically isolated CAN bus port. Learn more about batteries and battery charging To learn more about batteries and charging batteries, please refer to our book ‘Energy Unlimited’ (available free of charge from Victron Energy and downloadable from www.victronenergy.

 Open the catalog to page 1
Skylla-i Battery Charger 24V-2

Input voltage range (VAC) Input voltage range (VDC) Maximum AC input current @ 180 VAC Power factor Charge voltage 'absorption' (VDC) (1) Charge voltage 'float' (VDC) Charge voltage ‘storage’ (VDC) Charge current (A) (2) Charge current starter batt. (A) Charge algorithm Charge algorithm, Li-Ion 3 stage, with on-off control or CAN bus control Temperature sensor Can be used as power supply Remote on-off port CAN bus communication port (VE.Can) Two RJ45 connectors, NMEA2000 protocol, galvanically isolated Synchronised parallel operation Alarm relay Forced cooling Battery reverse polarity (fuse)...

 Open the catalog to page 2

All Victron Energy catalogs and brochures

  1. BMV-712 Smart

    2  Pages

  2. Skylla 24/48V

    2  Pages

  3. Filax 2

    1  Page

  4. 2021 Marine

    120  Pages

  5. Mobility

    8  Pages

  6. Energy Storage

    64  Pages

  7. EasyPlus

    4  Pages

  8. 2016 Marine

    108  Pages

  9. solarswitch

    8  Pages

  10. vgr

    4  Pages

  11. ECOmulti

    2  Pages

  12. Brochure marine

    108  Pages

  13. Skylla-i

    2  Pages

  14. Quattro

    2  Pages

Archived catalogs

  1. Converters

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.