Quattro - 1

Quattro inverter / charger 3kVA - 10kVA Lithium Ion battery compatible Two AC inputs with integrated transfer switch The Quattro can be connected to two independent AC sources, for example shore-side power and a generator, or two generators. The Quattro will automatically connect to the active source. Two AC Outputs The main output has no-break functionality. The Quattro takes over the supply to the connected loads in the event of a grid failure or when shore/generator power is disconnected. This happens so fast (less than 20 milliseconds) that computers and other electronic equipment will continue to operate without disruption. The second output is live only when AC is available on one of the inputs of the Quattro. Loads that should not discharge the battery, like a water heater for example, can be connected to this output. Virtually unlimited power thanks to parallel operation Up to 10 Quattro units can operate in parallel. Ten units 48/10000/140, for example, will provide 90kW / 100kVA output power and 1400 Amps charging capacity. Three phase capability Three units can be configured for three-phase output. But that’s not all: up to 10 sets of three units can be parallel connected to provide 270kW / 300kVA inverter power and more than 4000A charging capacity. PowerControl – Dealing with limited generator, shore-side or grid power The Quattro is a very powerful battery charger. It will therefore draw a lot of current from the generator or shore side supply (16A per 5kVA Quattro at 230VAC). A current limit can be set on each AC input. The Quattro will then take account of other AC loads and use whatever is spare for charging, thus preventing the generator or shore supply from being overloaded. PowerAssist – Boosting shore or generator power This feature takes the principle of PowerControl to a further dimension allowing the Quattro to supplement the capacity of the alternative source. Where peak power is so often required only for a limited period, the Quattro will make sure that insufficient shore or generator power is immediately compensated for by power from the battery. When the load reduces, the spare power is used to recharge the battery. Solar energy: AC power available even during a grid failure The Quattro can be used in off grid as well as grid connected PV and other alternative energy systems. System configuring has never been easier After installation, the Quattro is ready to go. If settings have to be changed, this can be done in a matter of minutes with a new DIP switch setting procedure. Even parallel and 3-phase operation can be programmed with DIP switches: no computer needed! Alternatively, VE.Net can be used instead of the DIP switches. And sophisticated software (VE.Bus Quick Configure and VE.Bus System Configurator) is available to configure several new, advanced, features.

Open the catalog to page 1
Quattro - 2

Quattro PowerControl / PowerAssist Integrated Transfer switch AC inputs (2x) Maximum feed through current (A) Input voltage range (V DC) Output (1) Cont. output power at 25 °C (VA) (3) Cont. output power at 25 °C (W) Cont. output power at 40 °C (W) Peak power (W) Maximum efficiency (%) Zero-load power (W) Zero load power in AES mode (W) Zero load power in Search mode (W) Charge voltage 'absorption' (V DC) Charge voltage 'float' (V DC) Storage mode (V DC) Charge current house battery (A) (4) Charge current starter battery (A) Battery temperature sensor Auxiliary output (A) (5) Programmable...

Open the catalog to page 2

All Victron Energy catalogs and brochures

  1. Marine

    120 Pages

  2. Filax 2

    1 Pages

  3. Mobility

    8 Pages

  4. Energy Storage

    64 Pages

  5. EasyPlus

    4 Pages

  6. Marine

    108 Pages

  7. solarswitch

    8 Pages

  8. vgr

    4 Pages

  9. Brochure marine

    108 Pages

  10. Skylla-i

    2 Pages

  11. ECOmulti

    2 Pages

Archived catalogs

  1. Converters

    2 Pages