Catalog excerpts
BIDERECTIONAL CONVERTER In case of overload the ECOmulti will import power from the grid to prevent system shutdown. GridAssist function Maximum AC current feed-through AC voltage Cont. output power at 25 °C Cont. output power at 25 °C Cont. output power at 40 °C Peak power Maximum efficiency Power factor range (when connected to the grid) Zero-load power (W) 94% 0,7 inductive to 0,7 capacitive (programmable) 15 W Zero load power in AES mode 10 W (island mode operation with AC output lowered to 200 V when load < 50 Watt) Charge voltage 'absorption' Charge voltage 'float’ Maximum charge current Maximum battery depth of discharge (DoD) 80% To connect additional loads once the battery has been fully charged: 16 A relay Auxiliary output Programmable relay For monitoring, alarm or other purposes For parallel and three phase operation, remote monitoring, remote control and system integration VE.Bus communication port General purpose communication port Remote on-off BATTERY Technology Lithium Iron Phosphate Nominal voltage Nominal energy at 25°C Nominal capacity at 25°C Nominal capacity at 0°C 45 Ah Cell balancing, and system shutdown in case of cell over voltage, cell under voltage and over temperature Battery Management System Cycle life, 80% DoD Cycle life, 70% DoD Cycle life, 50% DoD Max storage time at 25 °C 2000 cycles 3000 cycles 5000 cycles 1 year OTHER Display Operating temperature Storage temperature Protection category Humidity Warranty Graphical display Graphical User Interface (GUI) Ethernet (standard) and Wifi (optional) for remote monitoring and control Data storage and graphical display on vrm.victronenergy.com Android and iPhone apps -20 to + 40°C -40 to + 50°C IP22 95% non condensing System: 5 years Battery: 3 years full warranty plus 7 years prorated warranty ENCLOSURE Colour Weight Dimensions (hxwxd) Blue RAL 5012 Without battery: 28 kg With battery: 60 kg 475 x 575 x 360 mm STANDARDS Safety Emission, Immunity Victron Energy B.V. / De Paal 35 1351 JG Almere / The Netherlands Phone: +31 (0)36 535 97 00 Fax: +31 (0)36 535 97 40 e-mail: sales@victronenergy.com www.victronenergy.com A simple wall mounted energy storage solution Nighttime During the night the ECOmulti is disconnected from the grid. The home is powered by energy stored in the battery. The ECOmulti will reconnect the grid when the battery is discharged. Battery charging The next day, when the PV array produces sufficient power to supply the loads and to start charging the battery, the ECOmulti will regulate charge current to absorb nearly 100% of the surplus PV power. Discharging during the day When PV output is reduced by clouds or when a power hungry load is switched on, resulting in no surplus PV power available, battery charging will stop. Insufficient PV power will be supplemented by power from the ECOmulti. In case of overload power will be imported from the grid to supplement power from the ECOmulti (GridAssist function), and system shut down due to overload will be prevented. Battery fully charged Once the battery is fully charged, additional loads (for example the water heater) can be switched on, or surplus power will be exported to the grid. End of the day The ECOmulti disconnects from the grid about 10 minutes after PV power has become insufficient to provide any charge current. In order to prevent false disconnections due to lack of sun during the day, the inverter/charger also uses an internal timer to predict the end of the day. UPS function When the grid fails, the ECOmulti will continue to power the home.
Open the catalog to page 1A simple wall mounted energy storage solution At roughly 30 to 40 degrees latitude (Los Angeles, Marseille, Sevilla) a 1 kWp resp. 2 kWp array will do. A larger PV array will increase feedback into the grid, but not substantially increase battery utilization and self sufficiency. Increasing storage capacity More battery storage capacity will reduce feedback into the grid and increase self sufficiency, especially during the summer season. To increase self sufficiency during wintertime both the battery and the PV array have to be enlarged. A simple wall mounted energy storage solution The...
Open the catalog to page 2All Victron Energy catalogs and brochures
-
Blue Smart IP22Charger
1 Pages
-
Blue Smart Charger
2 Pages
-
MPPT 250/60 and MPPT 250/70
2 Pages
-
BMV-712 Smart
2 Pages
-
Centaur Charger
2 Pages
-
Quattro Inverter/Charger120V
2 Pages
-
Telecom Batteries
1 Pages
-
ArgoDiode Battery Isolators
1 Pages
-
Cyrix-ct 12/24V120A and 230A
2 Pages
-
Cyrix Li-ion 230A series
2 Pages
-
Cyrix Li-ion 120 A series
2 Pages
-
BatteryProtect
1 Pages
-
Skylla 24/48V
2 Pages
-
ARGO Diode Battery Combiners
1 Pages
-
Gel and AGM Batteries
4 Pages
-
Color Control GX
4 Pages
-
Shore Power Cable
1 Pages
-
Battery Balancer
2 Pages
-
Lynx Shunt VE.Can
32 Pages
-
2021 Marine
120 Pages
-
BlueSolar PWM-Pro
1 Pages
-
Filax 2
1 Pages
-
Mobility
8 Pages
-
Energy Storage
64 Pages
-
EasyPlus
4 Pages
-
Phoenix Battery Charger
2 Pages
-
Autotransformer 120/240V -
2 Pages
-
BatteryProtect 65A/100A/220A
1 Pages
-
BatteryProtect 48V-100A
1 Pages
-
2016 Marine
108 Pages
-
Skylla-i Battery Charger 24V
2 Pages
-
EasySolar 12V & 24V, 1600VA
2 Pages
-
Quattro 3kVA - 10kVA 230V
2 Pages
-
Isolation Transformers
2 Pages
-
Autotransformer 32A and 100A
2 Pages
-
Phoenix Inverter 3000VA - 5000VA
96 Pages
-
solarswitch
8 Pages
-
vgr
4 Pages
-
victron multipower
4 Pages
-
Brochure marine
108 Pages
-
BlueSolar MPPT 150/70
1 Pages
-
BlueSolar MPPT 100/15
1 Pages
-
BMV-700 series
2 Pages
-
Skylla-i
2 Pages
-
Quattro
2 Pages
-
Phoenix Charger
2 Pages
Archived catalogs
-
Converters
2 Pages
-
Marine Alternator
6 Pages
-
Phoenix Inverter
2 Pages
-
Battery Monitor
2 Pages
-
Centuar Charger
2 Pages
-
Phoenix MultiPlus
2 Pages