Catalog excerpts
BMV 700 series: Precision Battery Monitoring www.victronenergy.com Battery ‘fuel gauge’, time-to-go indicator, and much more The remaining battery capacity depends on the ampere-hours consumed, discharge current, temperature and the age of the battery. Complex software algorithms are needed to take all these variables into account. Next to the basic display options, such as voltage, current and ampere-hours consumed, the BMV-700 series also displays state of charge, time to go, and power consumption in Watts. The BMV-702 features an additional input which can be programmed to measure the voltage (of a second battery), temperature or midpoint voltage (see below). Easy to install All electrical connections are to the quick connect PCB on the current shunt. The shunt connects to the monitor with a standard RJ12 telephone cable. Included: RJ 12 cable (10 m) and battery cable with fuse (2 m); no other components needed. Also included are a separate front bezel for a square or round display appearance; a securing ring for the rear mounting and screws for the front mounting. Easy to program A quick install menu and a detailed setup menu with scrolling texts assists the user when going through the various settings. Please consult the manual for details. New: midpoint voltage monitoring (BMV-702 only) This feature which is often used in industry to monitor large and expensive battery banks, is now for the first time made available at a low cost, to monitor any battery bank. A battery bank consists of a string of series connected cells. The midpoint voltage is the voltage halfway along the string. Ideally, the midpoint voltage would be exactly half of the total voltage. In practice, however, deviations will be seen, dependent on many factors such as a different state of charge for new batteries or cells, different temperatures, internal leakage currents, capacities and much more. BMV shunt 500A/50mV With quick connect pcb Large or increasing deviation of the midpoint voltage, points to improper battery care or a failed battery or cell. Corrective action following a midpoint voltage alarm can prevent severe damage to an expensive battery. Please consult the BMV manual for more information. Standard features - Battery voltage, current, power, ampere-hours consumed and state of charge - Time to go at the current rate of discharge - Programmable visual and audible alarm - Programmable relay, to turn off non critical loads or to run a generator when needed. - 500 Amp quick connect shunt and connection kit - Shunt selection capability up to 10.000 Amps - VE.Direct communication port - Stores a wide range of historical events, which can be used to evaluate usage patterns and battery health - Wide input voltage range: 9,5 – 95 V - High current measurement resolution: 10 mA (0,01A) - Low current consumption: 2,9 Ah per month (4 mA) @12V and 2,2 Ah per month (3mA) @ 24V BMV 702 Black BMV-702 additional features Additional input to measure voltage (of a second battery), temperature or midpoint voltage, and corresponding alarm and relay settings. BMV 700HS: 60 to 385VDC voltage range No prescaler needed. Note: suitable for systems with grounded minus only (battery monitor is not isolated from shunt). Other battery monitoring options - VE.Net Battery Controller - High voltage VE.Net Battery Controller: 70 to 350VDC - Lynx Shunt VE.Net - Lynx Shunt VE.Can BMV 700H
Open the catalog to page 1Battery monitor Supply voltage range Current draw, back light off Input voltage range, auxiliary battery Battery capacity (Ah) Operating temperature range Measures voltage of second battery, or temperature, or midpoint Temperature measurement range VE.Direct communication port Victron Global Remote The Global Remote is a modem which sends alarms, warnings and system status reports to cellular phones via text messages (SMS). It can also log data from Victron Battery Monitors, MultiPlus units, Quattros and Inverters to a website through a GPRS connection to the VRM Portal. Access to this...
Open the catalog to page 2All Victron Energy catalogs and brochures
-
Blue Smart IP22Charger
1 Pages
-
Blue Smart Charger
2 Pages
-
MPPT 250/60 and MPPT 250/70
2 Pages
-
BMV-712 Smart
2 Pages
-
Centaur Charger
2 Pages
-
Quattro Inverter/Charger120V
2 Pages
-
Telecom Batteries
1 Pages
-
ArgoDiode Battery Isolators
1 Pages
-
Cyrix-ct 12/24V120A and 230A
2 Pages
-
Cyrix Li-ion 230A series
2 Pages
-
Cyrix Li-ion 120 A series
2 Pages
-
BatteryProtect
1 Pages
-
Skylla 24/48V
2 Pages
-
ARGO Diode Battery Combiners
1 Pages
-
Gel and AGM Batteries
4 Pages
-
Color Control GX
4 Pages
-
Shore Power Cable
1 Pages
-
Battery Balancer
2 Pages
-
Lynx Shunt VE.Can
32 Pages
-
2021 Marine
120 Pages
-
BlueSolar PWM-Pro
1 Pages
-
Filax 2
1 Pages
-
Mobility
8 Pages
-
Energy Storage
64 Pages
-
EasyPlus
4 Pages
-
Phoenix Battery Charger
2 Pages
-
Autotransformer 120/240V -
2 Pages
-
BatteryProtect 65A/100A/220A
1 Pages
-
BatteryProtect 48V-100A
1 Pages
-
2016 Marine
108 Pages
-
Skylla-i Battery Charger 24V
2 Pages
-
EasySolar 12V & 24V, 1600VA
2 Pages
-
Quattro 3kVA - 10kVA 230V
2 Pages
-
Isolation Transformers
2 Pages
-
Autotransformer 32A and 100A
2 Pages
-
Phoenix Inverter 3000VA - 5000VA
96 Pages
-
solarswitch
8 Pages
-
vgr
4 Pages
-
victron multipower
4 Pages
-
Brochure marine
108 Pages
-
BlueSolar MPPT 150/70
1 Pages
-
BlueSolar MPPT 100/15
1 Pages
-
Skylla-i
2 Pages
-
Quattro
2 Pages
-
ECOmulti
2 Pages
-
Phoenix Charger
2 Pages
Archived catalogs
-
Converters
2 Pages
-
Marine Alternator
6 Pages
-
Phoenix Inverter
2 Pages
-
Battery Monitor
2 Pages
-
Centuar Charger
2 Pages
-
Phoenix MultiPlus
2 Pages