BlueSolar MPPT 150/70
1Pages

{{requestButtons}}

Catalog excerpts

BlueSolar MPPT 150/70 - 1

BlueSolar charge controller MPPT 150/70 & 150/85 www.victronenergy.com PV voltage up to 150 V The BlueSolar MPPT 150/70 and 150/85 charge controllers will charge a lower nominal-voltage battery from a higher nominal voltage PV array. The controller will automatically adjust to a 12, 24, 36, or 48 V nominal battery voltage. Ultra fast Maximum Power Point Tracking (MPPT) Especially in case of a clouded sky, when light intensity is changing continuously, an ultra fast MPPT controller will improve energy harvest by up to 30% compared to PWM charge controllers and by up to 10% compared to slower MPPT controllers. Advanced Maximum Power Point Detection in case of partial shading conditions If partial shading occurs, two or more maximum power points may be present on the power-voltage curve. Conventional MPPT’s tend to lock to a local MPP, which may not be the optimum MPP. The innovative BlueSolar algorithm will always maximize energy harvest by locking to the optimum MPP. Outstanding conversion efficiency Maximum efficiency exceeds 98%. Full output current up to 40°C (104°F). Flexible charge algorithm Several preprogrammed algorithms. One programmable algorithm. Manual or automatic equalisation. Battery temperature sensor. Battery voltage sense option. Solar charge controllers MPPT 150/70 and 150/85 Programmable auxiliary relay For alarm or generator start purposes Extensive electronic protection Over-temperature protection and power derating when temperature is high. PV short circuit and PV reverse polarity protection. Reverse current protection. BlueSolar charge controller Nominal battery voltage Rated charge current Maximum solar array input power 1) 150V absolute maximum coldest conditions 145V start-up and operating maximum Maximum PV open circuit voltage Minimum PV voltage Battery voltage plus 7 Volt to start Standby power consumption Battery voltage plus 2 Volt operating Efficiency at full load Absorption charge Float charge Equalization charge Remote battery temperature sensor Default temperature compensation setting Remote on/off Programmable relay Communication port Parallel operation Operating temperature Cooling Yes -2,7mV/° per 2V battery cell C No DPST VE.Can: two paralleled RJ45 connectors, NMEA2000 protocol Yes, through VE.Can. Max 25 units in parallel -40° to 60° with output current derating above 40°C C C Natural Convection Terminal size Material & color Protection class Weight Dimensions (h x w x d) Mounting 4,2 kg 350 x 160 x 135 mm Vertical wall mount Indoor only 1) If more solar power is connected, the controller will limit input power to the stated maximum Victron Energy B.V. | De Paal 35 | 1351 JG Almere | The Netherlands General phone: +31 (0)36 535 97 00 | Fax: +31 (0)36 535 97 40 E-mail: sales@victronenergy.com | www.victronenergy.com

Open the catalog to page 1

All Victron Energy catalogs and brochures

  1. Marine

    120 Pages

  2. Filax 2

    1 Pages

  3. Mobility

    8 Pages

  4. Energy Storage

    64 Pages

  5. EasyPlus

    4 Pages

  6. Marine

    108 Pages

  7. solarswitch

    8 Pages

  8. vgr

    4 Pages

  9. Brochure marine

    108 Pages

  10. Skylla-i

    2 Pages

  11. Quattro

    2 Pages

  12. ECOmulti

    2 Pages

Archived catalogs

  1. Converters

    2 Pages