Catalog excerpts
Standard equipment Additional equipment option n tainless steel housing S n ntegrated G4 air filters as Z-line filters, separately for process and regeneration I n illenium microprocessor control with four-line plain text display M air n ilter monitoring with warning light F n otor rotation control R n 4 V DC control voltage 2 n otential-free signal contacts for maintenance / filter change, fault, operation P ON / OFF n erminals for hygrostat, 24 V DC T n erminals for external switch-on/off, 24 V DC T n irectly driven high-performance EC fans with manual speed adjustment D integrated in the housing (no additional throttle valves required), separately for process and regeneration air n ilica gel sorption rotor with internal purging sector for heat recovery and S automatically adjusting rotor seal kit n otor drive system with brushless, variable-speed gear motor, toothed belt, R toothed belt pulley and belt tensioner n lectric regeneration air heater comprising tubular heating elements, equipped E with safety temperature limiters and differential pressure switch, controlled via semi-conductor relay(s) n emperature-controlled rundown period T n ntegrated control cabinet with all the equipment and supplies required for I operation complying with the TROTEC standard: emergency stop main switch, selection switch for remote / on-site operation, indicator lights, buttons, switching devices, fuses, wiring and terminals n ousing prepared for mirror-inverted assembly; air direction reversal; standard H process air flow direction from left to right Trotec GmbH Grebbener Straße 7 52525 Heinsberg info@trotec.com www.trotec.om E rror messages in plain text E nergy management (temperature-dependent regeneration air heater control) n umidity regulation dry air (only in combination with optional moisture H measuring device and signal transducer kit 4–20 mA / 0–10 V) n emperature regulation dry air (only with optional temperature probe and T downstream air conditioning) n lowmatic S, separate electronic fan speed control for process and regeneration F air, controlled to a constant volumetric flow or pressure depending on the process-related target value, control signal 0…10 V or 4–20 mA n team heater for regeneration air (saturated steam P > 3 barg) S n dditional electrical heating for dry air A n ntegrated heat exchanger (cold/warm water) for dry air temperature control I n oosted or additional fan for higher compression of dry air B n rotection and transport frame with wheels, stackable P n heels W n ygienic equipment (fans and rotor with hygienic design) H n eather protection equipment W n umidity / temperature control (signal transducer kit 4–20 mA / 0–10 V, H parameterization) n lectronic hygrostat HG125 with two-line LC display E n ew point sensor (-100 - +20 °Cdp / signal 4–20 mA) D n WIS-free model P n irror-inverted module assembly – for reversed air flow direction M n T 100 temperature probe P n n Managing Directors: Detlef
Open the catalog to page 1Desiccant dehumidifier TTR 2000 General technical data (at 20 ° C / 60% rh, 1013 mbar) Dehumidification Air volume nominal Compression Power input Recommended fusing A) Prozessluft-Eintritt processair inlet B) Regenerationsluft-Eintritt regen.-air inlet C) Feuchluft-Austritt wetair outlet D) Trockenluft-Austritt dryair outlet Platzbedarf space requirement Subject to change without notice. All performance data refer to 1013 mbar, a density of 1.2 kg/m³ and a power supply with 3x400 V/50Hz +PE or 230V/50 Hz. For your project design we recommend to consider a safety discount of 10-20 % for the...
Open the catalog to page 2All TROTEC GmbH catalogs and brochures
-
Electric heater TEH 200
2 Pages
-
Industrial dryer DH 160
1 Pages
-
TTR 1400
2 Pages
-
TTR 800
2 Pages
-
Trotec PowerTools program 1|2019
92 Pages