FC

FC

FC

Product catalog summary
Overview
The document provides technical specifications and features of the FC series fan coils, designed for marine use. These fan coils are compact and suitable for low-level installation, such as inside furniture or under beds. They are available in models ranging from 5,000 to 24,000 BTU/h, with options for customization.

Specifications
The fan coils operate under specific conditions: cooling with a water inlet temperature of 7°C and outlet temperature of 12°C, and ambient air inlet temperature of 27°C. They feature a finned heat exchange coil, high-efficiency centrifugal fans, and stainless steel condensate trays.

Models and Capacities
The document lists seven models: FC05, FC08, FC10, FC13, FC16, FC18, and FC24, with capacities ranging from 5,000 to 24,000 BTU/h. Each model has specific power supply requirements, air flow rates, and water flow rates.

Technical Data
Key technical data includes:
  • Power supply: 230/1/50-60 V-Ph-Hz
  • Full load amps (FLA) for blower: varies by model
  • Nominal power input: 130-260 W
  • Max circuit breaker: 1-2 A
  • Air flow rate: 400-2x470 mc/h
  • Water connections diameter: 16 mm
  • Pressure drop: varies by model

Dimensions and Weight
The dimensions and weight of each model are specified, with lengths ranging from 334 to 590 mm, depths from 174 to 246 mm, heights from 240 to 290 mm, and weights from 5.5 to 13 kg.

Additional Features
Some models can be equipped with air sanitation technology, and customization options are available for capacity and size.
See more

Catalog excerpts

FC-1

Terminali idronici Fan coil 5.000 - 24.000 BTU/h Comando fan coil elettromeccanico electromechanical fan coil controller Comando fan coil digitale Digital fan coil controller Sistema di sterilizzazione Sterilization system UVA/UVC

 Open the catalog to page 1
FC-2

Caratteristiche tecniche Specifications Model Capacity BTU/h Power supply V-Ph-Hz Full loads amps FLA blower A Nominal power input W Min duct size diam. In Water connections diam. mm Water flow rate L/min - m3/h I dati tecnici si riferiscono alle seguenti condizioni di funzionamento: Raffreddamento: temperatura acqua in ingresso 7°C; temperatura acqua in uscita 12°C; temperatura aria ambiente in ingresso 27°Cb.s. 19°Cb.u. Portata aria e velocità ventilatore: prestazioni dell’unità con filtro aria pulito 27°Cb.s. 19°Cb.u. Portata aria e velocità ventilatore: prestazioni dell’unità con filtro aria...

 Open the catalog to page 2

All Thermowell catalogs and brochures

  1. IM20

    1  Page

  2. VC

    2  Pages

  3. UTA

    2  Pages

  4. EXT

    2  Pages