Catalog excerpts
Cooling power source KW min 3 std 16 max 25 Heating power source KW min 3 std 16 max 25 Total BTU Capacity: Power supply: Sea water pump: Size W x D x H: Weight: Sea water working range: Air working range: Noise: Vibration: Sea water pipes connection: Comparable to 341.000 BTU/h of the competitors. 380 - 440 Vac / 50-60 Hz 3ph (VRT100E2-4V) 700 Vdc (VRT100E2-7V) on request Magnetic type. Centrifugal 500lt/min 1,7kw included in unit power consumption. 1408 x 721 x 794 mm 192 Kg +3°C to +40°C Option polar water: -5°C -20°C to +50°C Compressor @ 140 hz - 73db @ 1 meter from box No significant vibration transmitted to the feet 2'' Compressor box use VRV inverter architecture with refrigerant circulation inside air handler Databus rs485 modbus on board System based on Toshiba VFD and twin rotary compressor MARINE INVERTER AIR CONDITIONING www.termodinamicamarine.com
Open the catalog to page 1MAIN FEATURES Titanium Grade 2. No fouling, no corrosion. 3 times lighter than copper nickel COMPRESSOR: Toshiba inverter twin rotary. COP > 4 SOFTWARE MANAGEMENT: Compressor high temperature, low temperature, high pressure condenser,low pressure compressor, electronic pressure gas, electronic pressure liquid,Condensation control, Evaporation control COMPRESSOR PROTECTION: Over/undervoltage, overcurrent, torque, winding temperature, stepout (bad lubrication), power input, power output, efficiency, overload, oil level (with EEV) Microprocessor board with rs485 modbus rtu communication....
Open the catalog to page 2VRT100E2 PERFORMANCE CURVE DC VRV30E1 INVERTER 70 rps/100 CONDENSING TEMP. (°C) EVAPORATING TEMP. (°C) CONDENSING TEMP. (°C) 37
Open the catalog to page 3ELECTRICAL CONNECTION^ VRT100E2-4V - VRT100E2-7V ELECTRICAL CONNECTION ELECTRIC BOX INVERTER PANEL TERMQINAMICA MARINE INVERTER AIR CONDITIONING
Open the catalog to page 4TERMOINAMICA MARINE INVERTER AIR CONDITIONING
Open the catalog to page 5