VRT 100E2

VRT 100E2

VRT 100E2

Product catalog summary
Specifications:
Total BTU Capacity: Comparable to 341,000 BTU/h.
Power Supply: 380 - 440 Vac / 50-60 Hz 3ph (VRT100E2-4V), 700 Vdc (VRT100E2-7V) on request.
Sea Water Pump: Magnetic type, centrifugal 500lt/min, 1.7kw included in unit power consumption.
Dimensions: 1408 x 721 x 794 mm.
Weight: 192 Kg.
Sea Water Working Range: +3°C to +40°C, option for polar water: -5°C.
Air Working Range: -20°C to +50°C.
Noise Level: Compressor at 140 Hz – 73db at 1 meter.
Vibration: No significant vibration transmitted to the feet.
Sea Water Pipes Connection: 2’’.
Main Features:
Condenser: Titanium Grade 2, no fouling, no corrosion, 3 times lighter than copper nickel.
Compressor: Toshiba inverter twin rotary, COP > 4, rotation speed: 600 to 6000 rpm.
Frame: Stainless Steel 316.
Software Management: Includes controls for compressor temperature, pressure, condensation, and evaporation.
Compressor Protection: Over/undervoltage, overcurrent, torque, winding temperature, stepout, power input/output, efficiency, overload, oil level (with EEV).
Electronic: Microprocessor board with rs485 modbus RTU communication, interface to Termodinamica air handling unit or fresh air unit.
Performance:
Cooling Capacity: Min 10 kW, Std 80 kW, Max 100 kW.
Cooling Power Source: Min 3 kW, Std 16 kW, Max 25 kW.
Heating Capacity: Min 10 kW, Std 80 kW, Max 110 kW.
Heating Power Source: Min 3 kW, Std 16 kW, Max 25 kW.
Graphical Data:
The performance curve indicates the relationship between condensing and evaporating temperatures, showing efficiency at various operational points.
See more

Catalog excerpts

VRT 100E2-1

Cooling power source KW min 3 std 16 max 25 Heating power source KW min 3 std 16 max 25 Total BTU Capacity: Power supply: Sea water pump: Size W x D x H: Weight: Sea water working range: Air working range: Noise: Vibration: Sea water pipes connection: Comparable to 341.000 BTU/h of the competitors. 380 - 440 Vac / 50-60 Hz 3ph (VRT100E2-4V) 700 Vdc (VRT100E2-7V) on request Magnetic type. Centrifugal 500lt/min 1,7kw included in unit power consumption. 1408 x 721 x 794 mm 192 Kg +3°C to +40°C Option polar water: -5°C -20°C to +50°C Compressor @ 140 hz - 73db @ 1 meter from box No significant vibration transmitted to the feet 2'' Compressor box use VRV inverter architecture with refrigerant circulation inside air handler Databus rs485 modbus on board System based on Toshiba VFD and twin rotary compressor MARINE INVERTER AIR CONDITIONING www.termodinamicamarine.com

 Open the catalog to page 1
VRT 100E2-2

MAIN FEATURES Titanium Grade 2. No fouling, no corrosion. 3 times lighter than copper nickel COMPRESSOR: Toshiba inverter twin rotary. COP > 4 SOFTWARE MANAGEMENT: Compressor high temperature, low temperature, high pressure condenser,low pressure compressor, electronic pressure gas, electronic pressure liquid,Condensation control, Evaporation control COMPRESSOR PROTECTION: Over/undervoltage, overcurrent, torque, winding temperature, stepout (bad lubrication), power input, power output, efficiency, overload, oil level (with EEV) Microprocessor board with rs485 modbus rtu communication. Interface...

 Open the catalog to page 2
VRT 100E2-3

VRT100E2 PERFORMANCE CURVE DC VRV30E1 INVERTER 70 rps/100 CONDENSING TEMP. (°C) EVAPORATING TEMP. (°C) CONDENSING TEMP. (°C) 37

 Open the catalog to page 3
VRT 100E2-4

ELECTRICAL CONNECTION^ VRT100E2-4V - VRT100E2-7V ELECTRICAL CONNECTION ELECTRIC BOX INVERTER PANEL TERMQINAMICA MARINE INVERTER AIR CONDITIONING

 Open the catalog to page 4
VRT 100E2-5

TERMOINAMICA MARINE INVERTER AIR CONDITIONING