Data Sheet R-Series V RP5 SSI Magnetostrictive Linear Position Sensors Position measurement with a resolution up to 0.1 µm Update rate up to 10 kHz Field adjustments and diagnostics using the new TempoLink smart assistant
Open the catalog to page 1Temposonics® R-Series V RP5 SSI Data Sheet MEASURING TECHNOLOGY Position magnet (magnetic field) The absolute, linear position sensors provided by Temposonics rely on the company’s proprietary magnetostrictive technology, which can determine position with a high level of precision and robustness. Each Temposonics position sensor consists of a ferromagnetic waveguide, a position magnet, a strain pulse converter and supporting electronics. The magnet, connected to the object in motion in the application, generates a magnetic field at its location on the waveguide. A short current pulse is applied...
Open the catalog to page 2Data Sheet Optional internal linearization: Linearity tolerance (applies for the first magnet for differential measurement) Stroke length 25...300 mm typical ± 15 pm 1/ With standard one shot of 16 |js 2/ Sensor with standard settings. Further information can be found in the operation manual R-Series V SSI (document number: 552011) 3/ With position magnet # 252 182 i 3 1
Open the catalog to page 3Temposonics® R-Series V RP5 SSI Data Sheet TECHNICAL DRAWING RP5-M-A/-V, example: Connection type D70 (connector outlet) Sensor electronics housing 58 (2.28) Adjustable mounting clamp RP5-M-A/-V, example: Connection type D84 (connector outlet) Sensor electronics housing 58 (2.28) Adjustable mounting clamp RP5-M-A/-V, example: Connection type LXX / BXX / EXX / GXX / UXX (angled cable outlet) Sensor electronics housing 58 (2.28) Adjustable mounting clamp RP5-M-A/-V, example: Connection type HXX/PXX/ RXX/TXX (straight cable outlet) Null zone 28 (1.1) Adjustable mounting clamp Controlling design...
Open the catalog to page 4Data Sheet Cable Color Function For cable type TXX, the extra red & blue wires are not used. Fig. 4: Connector wiring cable outlet
Open the catalog to page 5Temposonics® R-Series V RP5 SSI Data Sheet FREQUENTLY ORDERED ACCESSORIES – Additional options available in our Accessories Guide Position magnets Magnet slider S, joint at top Part no. 252 182 Magnet slider V, joint at front Part no. 252 184 Magnet slider N longer ball-joint arm Part no. 252 183 Magnet slider G, backlash free Part no. 253 421 Material: GRP, magnet hard ferrite Weight: Approx. 35 g Operating temperature: −40…+85 °C (−40…+185 °F) Material: GRP, magnet hard ferrite Weight: Approx. 35 g Operating temperature: −40…+85 °C (−40…+185 °F) Material: GRP, magnet hard ferrite Weight: Approx....
Open the catalog to page 6Temposonics® R-Series V RP5 SSI Data Sheet M16 female connector (7 pin), straight M16 female connector (7 pin), angled M12 A-coded female connector Part no. 370 624 (8 pin), straight Part no. 560 779 Part no. 370 694 M12 A-coded female connector (8 pin), angled Part no. 370 699 Material: Zinc nickel plated Termination: Solder Contact insert: Silver plated Cable clamp: PG9 Cable Ø: 6…8 mm (0.24…0.31 in.) Operating temperature: −40…+100 °C (−40…+212 °F) Ingress protection: IP65/IP67 (correctly fitted) Fastening torque: 0.7 Nm Housing: GD-ZnAL Termination: Screw Contact insert: CuZn Cable Ø: 6…8...
Open the catalog to page 7Temposonics® R-Series V RP5 SSI Data Sheet PTFE cable Part no. 530 112 Material: PVC jacket; gray Features: Twisted pair, shielded, flexible Cable Ø: 6 mm (0.23 in.) Cross section: 3 × 2 × 0.14 mm2 Bending radius: 10 × D (fixed installation) Operating temperature: −40…+105 °C (−40…+221 °F) Material: PUR jacket; orange Features: Twisted pair, shielded, highly flexible, halogen free, suitable for drag chains, mostly oil & flame resistant Cable Ø: 6.4 mm (0.25 in.) Cross section: 3 × 2 × 0.25 mm2 Bending radius: 5 × D (fixed installation) Operating temperature: −30…+80 °C (−22…+176 °F) Material: PTFE...
Open the catalog to page 8Data Sheet ORDER CODE TirrirTI XX m/ft. PUR cable (part no. 530 052) (Note the temperature range of the cable!) See “Frequently ordered accessories” for cable specifications Standard stroke length (in.) Ordering steps Tmri XX m/ft. PUR cable (part no. 530 175) See “Frequently ordered accessories” for cable specifications Non-standard stroke lengths are available; must be encoded in 5 mm/0.1 in. increments. Tmri XX m/ft. PVC cable (part no. 530 032) See “Frequently ordered accessories” for cable specifications rmri XX m/ft. PTFE cable (part no. 530 112) See “Frequently ordered accessories” for...
Open the catalog to page 9Temposonics® R-Series V RP5 SSI Data Sheet o Additional options (optional) A No filter, error counter (4 cycles) 2 Differential measurement (2 magnets and 1 output) C No filter, error counter (8 cycles) D No filter, error counter (10 cycles) 4 Position and temperature in the sensor electronics housing; NOTICE In this case, only option “24 bit” can be l selected under “Data length”. G FIR filter (8 measurements), error counter (10 cycles) J IIR filter (filter grade 4) K IIR filter (filter grade 8) N IIR filter (filter grade 8), error counter (10 cycles) j Options 0 Standard 1 Internal linearization...
Open the catalog to page 10Temposonics® R-Series V RP5 SSI Data Sheet Alarm The alarm bit is set by the sensor if the sensor detects more magnets (extra magnet) or less magnets (magnet status error) than configured. Asynchronous mode In asynchronous mode the position data is continuously updated inside the sensor as quickly as the sensor’s measurement cycle will allow, independent of the controller. The controller’s loop time will determine when the sensor’s most recent data is clocked out over the SSI interface. ( Synchronous mode) Parity The parity bit is a check bit that is added to a bit string to detect transmission...
Open the catalog to page 11UNITED STATES Americas & APAC Region Phone: +1 919 677-0100 E-mail: [email protected] Document Part Number: 552000 Revision D (EN) 03/2022 Temposonics 58513 Lüdenscheid GmbH & Co. KG Phone: +49 2351 9587-0 EMEA Region & India E-mail: [email protected] ITALY Phone: +39 030 988 3819 Branch Office E-mail: [email protected] FRANCE Phone: +33 6 14 060 728 Branch Office E-mail: [email protected] UK Phone: +44 79 21 83 05 86 Branch Office E-mail: [email protected] SCANDINAVIA Phone: + 46 70 29 91 281 Branch Office E-mail: [email protected] CHINA Phone: +86 21 2415...