1. Catalogs
  2. Temposonics GmbH & Co. KG
  3. Level Plus® – Tank SLAYER®

Level Plus® – Tank SLAYER®
1 /8Pages

Level Plus® – Tank SLAYER®

Level Plus® – Tank SLAYER®
1 /8Pages

Catalog excerpts

Level Plus® – Tank SLAYER®-1

I Magnetostrictive Liquid Level Transmitters with Temposonics® Technology I 4-IN-1 Measurement I Inherent Accuracy ±1 mm I API Temperature Corrected Volumes I Hazardous Area Certified

 Open the catalog to page 1
Level Plus® – Tank SLAYER®-2

Level Plus® Tank Slayer® Data Sheet MEASURING TECHNOLOGY The absolute, linear position sensors provided by Temposonics rely on the company’s proprietary Temposonics® magnetostrictive technology, which can determine position with a high level of precision and robustness. Each Temposonics® position sensor consists of a ferromagnetic waveguide, a position magnet, a strain pulse converter and supporting electronics. The magnet, connected to the object in motion in the application, generates a magnetic field at its location on the waveguide. A short current pulse is applied to the waveguide. This...

 Open the catalog to page 2
Level Plus® – Tank SLAYER®-3

Level Plus® Tank Slayer® Data Sheet

 Open the catalog to page 3
Level Plus® – Tank SLAYER®-4

Level Plus® Tank Slayer® Data Sheet TECHNICAL DRAWING 145 mm (5.7 in.) 114 mm (4.5 in.) 3/4 in. FNPT 152 mm (6.0 in.) Protection Method: I or X 1 in. MNPT or BSPP adustable (Welded flange optional) Tank flange (Customer supplied) Riser Welded flange Product float Measuring range Flexible hose Order length 1,575 mm (62 in.) to 22,000 mm (866 in.) Interface float Stop collar Total inactive zone Inactive zone please see table 51 mm (3 in.) typ. TRANSMITTER INACTIVE ZONE REFERENCE Order Length Inactive Zone Controlling design dimensions are in millimeters and measurements in ( ) are in i

 Open the catalog to page 4
Level Plus® – Tank SLAYER®-6

Level Plus® Tank Slayer® Data Sheet

 Open the catalog to page 6
Level Plus® – Tank SLAYER®-7

Data Sheet FREQUENTLY ORDERED ACCESSORIES - Additional options available in our Accessories Guide Q 551103 1. Be sure that the float specific gravity is at least 0.05 less than that of the measured liquid as a safety margin at ambient temperature. 2. For interface measurement: A minimum of 0.05 specific gravity differential is required between the upper and lower liquids. 3. When the magnet is not shown, the magnet is positioned at the center line of float. 4. Drawings contained in this document are for reference only. Contact the factory for engineering drawings. Long-gauge float Pressure Temperature...

 Open the catalog to page 7
Level Plus® – Tank SLAYER®-8

UNITED STATES Document Part Number: 551688 Revision H (EN) 01/2023 Americas & APAC Region Phone: +1 919 677-0100 E-mail: [email protected] Temposonics 58513 Lüdenscheid GmbH & Co. KG Phone: +49 2351 9587-0 EMEA Region & India E-mail: [email protected] ITALY Phone: +39 030 988 3819 Branch Office E-mail: [email protected] FRANCE Phone: +33 6 14 060 728 Branch Office E-mail: [email protected] UK Phone: +44 79 44 15 03 00 Branch Office E-mail: [email protected] SCANDINAVIA Phone: + 46 70 29 91 281 Branch Office E-mail: [email protected] CHINA Phone: +86 21 2415...

 Open the catalog to page 8
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.