1 Important safety Instructions Before using the inverter, read and save the safety instructions. 1.1 General safety instructions 1-1-1 Do not expose the inverter to rain, snow, spray, bilge or dust. To reduce risk of hazard, do not cover or obstruct the ventilation openings. Do not install the inverter in a zero-clearance compartment. To avoid a risk of fire or electric shock, make sure that the existing wiring is in good electrical condition; and that wire size is not undersized. Do not operate the inverter with damaged or substandard wiring. This equipment contains components that can...

Open the catalog to page 2
INVERTER - 3

• Pure Sine wave output (THD < 3%). • Output frequency: 50/60 Hz switch selectable. • Low consumption in "Power saving mode". • Totally isolated on inlet and on outlet. • Capable of driving highly reactive & capacitive loads at the start moment. • 3 LED indicators with tri-color display, all operation status.. • Loading controlled cooling fan. • Built in advanced microprocessor to make friendly interface with user. - Input over voltage and input low voltage - Power surges - Polarity inversion • Power tools : circular saws, drills, grinders, sanders, buffers, weed and hedge • Office...

Open the catalog to page 3
INVERTER - 4

Note : the specifications are subject to change without notice. TECSUP - Inverter - User manual 80300100 A - P 4 / 17

Open the catalog to page 4
INVERTER - 5

Note : : the specifications are subject to change without notice. TECSUP - Inverter - User manual 80300100 A - P 5 / 17

Open the catalog to page 5
INVERTER - 6

Circulation dair sine, NAVI iPUEHreK /n^m O TECSUP - Inverter - User manual 80300100 A - P 6 / 17

Open the catalog to page 6
INVERTER - 7

TECSUP - Inverter - User manual 80300100 A - P 7

Open the catalog to page 7
INVERTER - 8

This range of DC/AC inverters are part of the mobile alternative power supply systems, the most advanced available on the market today. To attain these optimal performances, the inverter must be installed correctly. Pleas read the instructions in this manual before using the inverter. 3.1 Operations on the front face PURE SINE WAVE INVERTER PURESINE WAVE INVERTER PURESINEWAVE INVERTER -Before using the inverter, make sure the main switch is « Off ». - Before using the remote control, make sure that the sitch is on « Remote ». TECSUP - Inverter - User manual 80300100 A - P 8 / 17

Open the catalog to page 8
INVERTER - 9

Current voltage reading Charge levels : Consomption display AC (Watts) Functioning mode display and the default causes Power Save Mode Selected and adjusted Dip Switches SI, S2 & S3 on the face plate. Example : with a 15W setting, a charge of more than 15 W will make the inverter work normally, but with a charge of less than 15 W, the inverter will commute to Power save mode. TECSUP - Inverter - User manual 80300100 A - P 9 / 17

Open the catalog to page 9
INVERTER - 10

3.2 Operations on the rear face Remote Control connector (remote port) : Available on option. Before using the remote control be sure that the main switch is on the « remote » 600 W model exclusivlv : ON/OFF terminal for remote control In order to make the remote control work, it is necessary that the switch be at the OFF position on the face of the inverter. Before connecting, make sure that the Make the connection between the remote and the terminal marked « Remote port » at the rear of the inverter with a 2,5 à 0,5 mm2 (14-20 AWG) cable section depending on the distance. If the contact...

Open the catalog to page 10
INVERTER - 11

Connect the earth terminal of the chassis to the chassis of the vehicle via an 8 mm2 - Using the inverter without an earth connection could result in a severe - Do not connect a 12 V inverter to a 24 V battery. The inverter would be instantly • Dry : Do not allow water to splash or drip onto the inverter. • Cool : Ambiant air temperature should be between 0°C & 40°C. The cooler the • Safety : Do not install the inverter near or in the battery compartment where flammable fumes exist, such as fuel storage areas or engine compartments. • Ventilated : Allow for at least 2,5 cm clearance minimum...

Open the catalog to page 11
INVERTER - 12

The following recommended cables are for the best performance of the inverter. Connect the cables to the power input terminals on the front panel of the inverter. The red terminal is positive (+) and the black terminal is negative (-). Insert the cables into the terminals and tighten the screw to clamp the wires securely. Make sure all the DC connections are tight (tighten from 11,7 to 13 Nm). Loose connections could result in overheating and become a potential hazard. The installation of the fuse must be on a positive cable. Failure to place the fuse on a "+" cable running between the...

Open the catalog to page 12
INVERTER - 13

Connection of the battery cables to the inverter Do not place anything between the battery and the surface of the terminal. Assemble exactly as indicated in the diagram. TECSUP - Inverter - User manual 80300100 A - P 13 / 17

Open the catalog to page 13
INVERTER - 14

Connecting the battery cable to Do not place anything between the battery and the surface of the terminal. Assemble exactly as indicated in the diagram. TECSUP - Inverter - User manual 80300100 A - P 14 / 17

Open the catalog to page 14
INVERTER - 15

The Earth ground cable at the AC outlet must go to the common ground (for example the earth terminal on an electrical board). Neutral to ground earth The phase and neutral are totally isolated from the ground chassis and consequently, from the earth cable. Differential circuit breakers (G.F.C.I : Ground Fault Circuit Interrupters) : The installations embedded in leasure vehicles (for North American approbations), necessitates protection via a differential trip switch of the totality of the connected circuits at the AC outlet for inverters equipped with an outlet terminal. Electrical...

Open the catalog to page 15
INVERTER - 16

4 Trouble shooting guide Do not open or dismantle the inverter. Attempting to repair the inverter yourself will expose you to the risk of electrical Very little maintenance is required to keep your inverter operating correctly. You should clean the exterior of the unit periodically with a damp cloth to prevent accumulation of dust and dirt. At the same time, tighten the screws on the DC input We guarantee this product against defaults in materials and workmanship for a period of 2 years from the date of purchase. All material returned directly by paid postage will be either repaired or...