Catalog excerpts
We are always thinking safety and environment for you Water Mist Fire Fighting System [ International patented ] X-MIST® SYSTEM extinguishes or controls fires by cooling, oxygen displacement by water vapor and radiant heat attenuation. The exceptional cooling effect of water mist is a result of the division of water into very fine droplets, which increase the total surface area available to absorb heat and maximizes the evaporation rate of the water. Water Mist Fire Fighting System for Machinery Space Applied Rule & Regulation • 2000 SOLAS Ch.Ⅱ-2, Reg. 10.5.6 • IMO MSC/Circ. 1387 System Sequence Fire Detection Nozzle Specification Type Major Component Pump Unit (MOV type) Main Control Panel Alarm Control Panel Receive fire data from detector consisted loop. Fire Monitor (Repeat Panel) Receive fire signal from alarm control panel. Operate pump/motor and section valve. Check an error of system. Local Control Panel Supply water to each protected area. Composed of pump/motor, MOV valve, motor starter panel. Benefits ■Motor operation valve with manual override ■No leakage while pump‘s running ■Easy maintenance The panel is installed at each section. Manual release of water mist. Smoke / Flame Detector Addressable type Receive fire data from main control panel. Display the state of fire at each section.
Open the catalog to page 1Water Mist Fire Fighting System for Machinery Space • This system is fire extinguishing system to protect machinery space of category A and cargo pump room. • This system should be capable of manual release and continuously supplying water for at least 30min. • This system should be supplied by both main and emergency sources of power and should be provided with an automatic change-over switch. • The capacity and design of system should be based on the complete protection of the space demanding the greatest volume of water. • The operation controls should be available at easily accessible...
Open the catalog to page 2Water Mist Fire Fighting System [ International patented ] Water Mist Fire Fighting System for Accommodation Regulation ■ 2004 SOLAS II-2 10.6 • 6.1 Sprinkler systems in passenger ships • 6.1.1 Passenger ships carrying more than 36 passengers shall be equipped with an automatic sprinkler, fire detection and fire alarm system of an approved type complying with the requirements of the Fire Safety Systems Code. • ANNEX: Amendments to revised guidelines for approval of sprinkler systems equivalent to that referred to in SOLAS REQULATION II-2/12 in the ANNEX to REQULATION A.800(19). • APPENDIX...
Open the catalog to page 3All TANKTECH catalogs and brochures
-
Storage Tank Cleaning M/C
2 Pages
-
Hold Cleaning Machine
2 Pages
-
NPM Series
1 Pages
-
Tank Cleaning Machine
1 Pages
-
JET GUN
2 Pages