Water Mist Fire Fighting System

Water Mist Fire Fighting System

Water Mist Fire Fighting System

Product catalog summary
Overview
The X-MIST® SYSTEM is a water mist fire extinguishing system designed to protect machinery spaces and cargo pump rooms by cooling, displacing oxygen with water vapor, and attenuating radiant heat. The system uses fine water droplets to maximize heat absorption and evaporation rates.

Specifications
  • Types: ELL, LL, HL with varying dimensions, pressure, flow rates, and K-Factors.
  • Nozzle Types: TC and TB with specific spacing, height, pressure, flow rate, and K-Factor.

System Components
  • Main Control Panel: Receives fire signals, operates pumps/motors, and checks system errors.
  • Alarm Control Panel: Receives fire data from detectors and displays fire status.
  • Local Control Panel: Supplies water to protected areas, composed of pump/motor, MOV valve, and motor starter panel.

Benefits
  • Environmentally friendly and future-oriented.
  • Ensures safety for crew and machinery.
  • High technology system that can replace CO2 and foam systems.
  • No need for recharging and inspection.

Regulations and Standards
  • Complies with SOLAS regulations and IMO guidelines.
  • Includes specific standards for sprinkler systems on passenger ships and cabin balconies.

Applications
  • Maximum ceiling height: 15.5m.
  • Maximum protected space volume: 4374m3.

Testing
  • Various tests conducted for bilge and ceiling fires.

System Diagram
Illustrates the integration of the water mist system with CO2 and foam systems.

Additional Information
Internationally patented and designed for easy maintenance with no leakage during operation.
See more

Catalog excerpts

Water Mist Fire Fighting System-1

We are always thinking safety and environment for you Water Mist Fire Fighting System [ International patented ] X-MIST® SYSTEM extinguishes or controls fires by cooling, oxygen displacement by water vapor and radiant heat attenuation. The exceptional cooling effect of water mist is a result of the division of water into very fine droplets, which increase the total surface area available to absorb heat and maximizes the evaporation rate of the water. Water Mist Fire Fighting System for Machinery Space Applied Rule & Regulation • 2000 SOLAS Ch.Ⅱ-2, Reg. 10.5.6 • IMO MSC/Circ. 1387 System Sequence Fire Detection Nozzle Specification Type Major Component Pump Unit (MOV type) Main Control Panel Alarm Control Panel Receive fire data from detector consisted loop. Fire Monitor (Repeat Panel) Receive fire signal from alarm control panel. Operate pump/motor and section valve. Check an error of system. Local Control Panel Supply water to each protected area. Composed of pump/motor, MOV valve, motor starter panel. Benefits ■Motor operation valve with manual override ■No leakage while pump‘s running ■Easy maintenance The panel is installed at each section. Manual release of water mist. Smoke / Flame Detector Addressable type Receive fire data from main control panel. Display the state of fire at each section.

 Open the catalog to page 1
Water Mist Fire Fighting System-2

Water Mist Fire Fighting System for Machinery Space • This system is fire extinguishing system to protect machinery space of category A and cargo pump room. • This system should be capable of manual release and continuously supplying water for at least 30min. • This system should be supplied by both main and emergency sources of power and should be provided with an automatic change-over switch. • The capacity and design of system should be based on the complete protection of the space demanding the greatest volume of water. • The operation controls should be available at easily accessible positions...

 Open the catalog to page 2
Water Mist Fire Fighting System-3

Water Mist Fire Fighting System [ International patented ] Water Mist Fire Fighting System for Accommodation Regulation ■ 2004 SOLAS II-2 10.6 • 6.1 Sprinkler systems in passenger ships • 6.1.1 Passenger ships carrying more than 36 passengers shall be equipped with an automatic sprinkler, fire detection and fire alarm system of an approved type complying with the requirements of the Fire Safety Systems Code. • ANNEX: Amendments to revised guidelines for approval of sprinkler systems equivalent to that referred to in SOLAS REQULATION II-2/12 in the ANNEX to REQULATION A.800(19). • APPENDIX A:...

 Open the catalog to page 3