Xtender series
1Pages

{{requestButtons}}

Catalog excerpts

Xtender series - 1

Xtender series Cos ϕ Maximum efciency Consumption OFF/Stand-by/ON * Output voltage * Output frequency Harmonic distortion Overload and short-circuit protection Overheat protection Battery charger Internet based communication sets Xcom-LAN, Xcom-GSM Remote Control Module RCM-10 (3 m) 2 aux. contacts module ARM-02 Cooling Module ECF-01 Battery temp. sensor BTS-01 (3 m) Communication cable for 3ph and // CAB-RJ45-8-2 Mounting frame X-Connect 6 steps : Bulk-Absorption-Floating-Equalization-reduced oating-periodic absorption Number of steps, thresholds, end current and times completely adjustable with the RCC-02/-03 100A 55A 30A 90A 50A Module ARM-02 with 2 contacts, in option 8.2 kg 9 kg 9.3 kg 110x210x310 IP54 <15ms 2 independent contacts (potential free 3 points, 16Aac/5Adc) 16.2 kg 21.2 kg 133x322x466 IP20 Directive EMC 2004/108/EC : EN 61000-6-1, EN 61000-6-3, EN 55014, EN 55022, EN 61000-3-2, 62040-2 Low voltage directive 2006/95/EC : EN 62040-1-1, EN 50091-2, EN 60950-1 -20 to 55°C 95% without condensation Forced from 55°C <40dB / <45dB (without/with ventilation) 5 years Conformity Operating temperature range Relative humidity in operation Ventilation Acoustic level Warranty Accessoires Remote control RCC-02 or RCC-03 Module XCOM-232i 94% 96% 94% 1.4W/1.6W/9W 1.8W/2W/10W 1.4W/1.6W/12W Pure sine wave 230Vac (±2%) / 120Vac (1) 45Hz - 60Hz (1) ± 0.05% (crystal controlled) <2% Automatic disconnection with 3 time restart attempt Warning before shut-off - with automatic restart * Temperature compensation Power Factor Correction (PFC) General data * Input voltage range Input frequency Input current max. (transfer relay) / Output current max. Transfer time Multifunction contacts Weight Dimension hxwxl [mm] Protection index * Charge Characteristic * Maximum charging current 100% Optional cooling module ECF-01 ** These features are valid only when using the cooling module ECF-01. With -01 at the end of the reference, means 120V/60Hz. Available for all Xtenders except XTH 8000-48 Data may change without any notice. Model Inverter Nominal battery voltage Input voltage range Continuous power @ 25°C Power 30 min. @ 25°C Power 5 sec. @ 25°C Maximum load Maximum asymmetric load * Load detection (stand-by)

Open the catalog to page 1

All Studer Innotec catalogs and brochures

  1. Série AJ

    23 Pages

  2. Xcom-SMS

    1 Pages

  3. MBC series

    1 Pages

  4. AJ series

    1 Pages

  5. VS-120

    2 Pages

  6. VS-70

    2 Pages

  7. SBM-02

    1 Pages

  8. MBW serie

    1 Pages

  9. MBR serie

    1 Pages

  10. MBI serie

    1 Pages

  11. SI serie

    1 Pages

  12. MPPT

    2 Pages

Archived catalogs