Catalog excerpts
Input voltage range Continuous power @ 25°C Power 30 min. @ 25°C Power 5 min. @ 25°C Power 5 sec. @ 25°C Maximum asymmetric load Max. efficiency (%) Cos j max. Detection of the load Current of short-circuit 2 sec. (exit) Output voltage Frequency Distortion THD (resistive load) Consumption Stand-by Consumption « ON » no load Overheat protection (±5°C) Overload and short circuit protection Reverse polarity protection by internal fuse Deep discharge battery protection Max. battery voltage Acoustic alarm General data Weight Dimensions hxwxl [mm] Protection index IP Certification ECE-R 10 (E24) EC conformity Operating temperature Relative humidity in operation Ventilation forced Acoustic level Warranty Approximate correction of Pnom Recommended battery capacity Length cables (Battery/left AC) Options Voltage max. Current max. Solar Principle regulator Absorption voltage Floating voltage Plug for remote control (RCM) * 120Vac/60Hz on request ** Standby with solar option -S Data may change without any notice. Shut off @ 0.87 x Unom - Automatic restart @ Unom Shut off @ >1.33 x Unom - Automatic restart @ < Umax Before low battery or overheating disconnection 2.4 kg Maximum asymmetric load Max. efficiency (%) Cos j max. Detection of the load Current of short-circuit 2 sec. (exit) Output voltage Frequency Distortion THD (resistive load) Consumption Stand-by Consumption « ON » no load Overheat protection (±5°C) Short circuit protection Reverse polarity protection by internal fuse Deep discharge battery protection 0.1 – 1 up to1000VA 0.1 – 1 up to 2000VA Adjustable : 1 - 20W 13Aac (26Aac*) 26Aac (52Aac*) Sine wave 230Vac (120Vac*) ±5% 50 Hz (60Hz*) ± 0.05% (crystal controlled) < 5% (@ Pnom. & Uin nom.) 1.2W 0.7W 13W 16W Shut down @ 75°C - Auto-restart @ 70°C Automatic disconnection with 2 time restart attempt 100A Not protected Shut off @ 0.87 x Unom - Automatic restart @ Unom Model Inverter Nominal battery voltage Input voltage range Acoustic alarm General data Weight Dimensions hxwxl [mm] Protection index IP Certification ECE-R 10 (E24) EC conformity Operating temperature Relative humidity in operation Ventilation forced Acoustic level Warranty Approximate correction of Pnom Recommended battery capacity Length cables (Battery/left AC) Options Voltage max. Current max. Solar Principle regulator Absorption voltage Floating voltage Remote control JT8 supplied with 5 m cable Shut off @ >1.33 x Unom - Automatic restart @ < Umax Before low battery or overheating disconnection 8.5 kg 142x428x84 IP 30 conforms to DIN 40050 • 18 kg 273x399x117 IP 20 conforms to DIN 40050 • • • EN 61000-6-1, EN 61000-6-3, EN 55014, EN 55022, EN 60950-1 -20°C up to +50°C 95% without condensation From 45°C ± 5°C < 45 dB (with ventilation) 5 years -1.5%/°C since +25°C > 5 x Pnom/Unom (recommended value in Ah) Model Inverter Nominal battery voltage
Open the catalog to page 1All Studer Innotec catalogs and brochures
-
Série AJ
23 Pages
-
Xcom-SMS
1 Pages
-
MBC series
1 Pages
-
Xtender series
1 Pages
-
VS-120
2 Pages
-
VS-70
2 Pages
-
SBM-02
1 Pages
-
MBW serie
1 Pages
-
MBR serie
1 Pages
-
MBI serie
1 Pages
-
MDCI and MDC series
1 Pages
-
SI serie
1 Pages
-
COMPACT series
1 Pages
-
MPPT
2 Pages
-
STUDER Catalogue
19 Pages
Archived catalogs
-
Xtender series
6 Pages