Catalog excerpts
Fi F Sys SALOON MASTER CABIN QALLEV ENGINE ROOM MAIN DECK UPPER DECK LAZZARETTE CVLINDER DOOR C Monitor up to 8 Zones The FR-8000 Fire Monitor provides an intelligent networked solution for the monitoring up of up to 8 zones. The system consists of the FR-8000 display (as seen above), one FR-100 8 zone sensor input unit, and up to two FEC-6 engine room relay units (optional).This system allows for the monitoring of up to two cylinder release doors and cylinder fill/empty switches. The system communicates via a 2-wire network cable with a maximum cable length of 1000 metres. FR-8000 DISPLAY UNIT Features include: • Full indication from one central location on your boat • Visual indication of fire or fault • Audible indication of fire or fault • Isolate any zone • All zone names programmable eg. saloon; engine room; upper deck; master cabin. • Backlight FR-100 The zone controller which manages the sensors. Features include: • 8 separate zone inputs • Output relays x 2 • Relay 1 and Relay 2 close on fire detection • Relay 2 opens when all zones OK FEC-6 The engine room controller unit (optional). Features include: • 6 relays • Output relay 1 to 4 = 10 A resistive @ 24VDC • Output relay 5 & 6 = 1 A resistive @ 30VDC • Relay 4 activated on a programmable timer • Relay 5 opens when alarm is muted • 4 inputs (for extinguisher cylinder empty/fill switches) f Supply Voltage: 12 ~ 32 Volts DC (Auto sensing) | Quiescent Current: 12 milliamps (with backlight off) Backlight Reverse polarity protected | Network cable length = 1000m | Voltage & EMI protected Data retention: 50 years (without power) Smart Switch | PO Box 272 | Waikanae 5250 | New Zealand
Open the catalog to page 1All Smart Switch Technologies catalogs and brochures
-
SEN-S/S100
1 Pages
-
NV-8000
1 Pages
-
SMF-001
1 Pages
-
BC-8000
1 Pages
-
FR-4000
1 Pages
-
TD-4000
1 Pages
-
TC-8000
1 Pages
-
TM-4000
1 Pages
-
FR-1600
1 Pages
-
Smart Switch Catalogue
29 Pages
-
THE SEN-S/S SENSOR
1 Pages
-
Smart Switch Solid
1 Pages
-
FS-2A
1 Pages
-
FC -006
1 Pages
-
SDP - 003 & SDP - 006
1 Pages
-
SMS-2
1 Pages
-
SMS8
1 Pages
-
PR-100
1 Pages
-
SM-420
1 Pages
-
SM-180
1 Pages
-
FC - 8000
1 Pages
-
AM 100
1 Pages
-
NAV-8
1 Pages
-
FS 2A
1 Pages
-
SEN 100
1 Pages
-
IF 100
1 Pages
-
NMEA 0183
1 Pages
-
SPT 001 / SDP 003
1 Pages
-
ST 660
1 Pages
-
NV 2000
1 Pages
-
NV 8000
1 Pages
-
FR 8000
2 Pages
-
TM 4000
1 Pages
Archived catalogs
-
BSW 1000
1 Pages
-
TD 4000
1 Pages
-
Deluxe Toilet Controller
1 Pages
-
Toilet Contoller
1 Pages
-
AL 8000
1 Pages
-
TC 8000
1 Pages
-
BC 8000
1 Pages