FR-1600

FR-1600

Product catalog summary
Overview: The FR-1600 Fire Monitor is an advanced networked system designed for monitoring up to 16 zones, ideal for marine applications. It includes the FR1600 display, two FR-100 sensor input units, and optionally, up to two FEC-6 engine room relay units.
System Components:
  • FR-1600 Display Unit: Centralized monitoring with visual and audible alerts for fire or faults. Features include zone isolation, programmable zone names, and a backlight.
  • FR-100 Zone Controller: Manages up to 8 separate zone inputs with two output relays. Relays close on fire detection and open when all zones are clear.
  • FEC-6 Engine Room Controller (Optional): Includes 6 relays with specific outputs for different functions, such as programmable timers and alarm muting. It also supports inputs for extinguisher cylinder status.
Technical Specifications:
  • Supply Voltage: 12 ~ 32 Volts DC with auto-sensing.
  • Quiescent Current: 12 milliamps with backlight off.
  • Network Cable Length: Up to 1000 meters.
  • Data Retention: 50 years without power.
  • Protection: Reverse polarity, voltage, and EMI protected.
Key Features:
  • Monitors up to 16 zones with a 2-wire network communication.
  • Supports monitoring of cylinder release doors and fill/empty switches.
  • Provides full indication from a central location on a boat.
See more

Catalog excerpts

FR-1600-1

Fire Alarm System FR-1600 Monitor up to 16 Zones The FR-1600 Fire Monitor provides an intelligent networked solution for the monitoring up of up to 16 zones. The system consists of the FR1600 display (as seen above), two FR-100 8 zone sensor input units, and up to two FEC6 engine room relay units (optional). This system allows for the monitoring of up to two cylinder release doors and cylinder fill/empty switches. The system communicates via a 2-wire network cable with a maximum cable length of 1000 metres. FR-1600 DISPLAY UNIT Features include: • Full indication from one central location on your boat • Visual indication of fire or fault • Audible indication of fire or fault • Isolate any zone • All zone names programmable eg. saloon; engine room; upper deck; master cabin. • Backlight FR-100 The zone controller which manages the sensors. Features include: • 8 separate zone inputs • Output relays x 2 • 10 A resistive @ 24VDC • Relay 1 and Relay 2 close on fire detection • Relay 2 opens when all zones OK FEC-6 The engine room controller unit (optional). Features include: • 6 relays • Output relay 1 to 4 = 10 A resistive @ 24VDC • Output relay 5 & 6 = 1 A resistive @ 30VDC • Relay 4 activated on a programmable timer • Relay 5 opens when alarm is muted • 4 inputs (for extinguisher cylinder empty/fill switches) Supply Voltage: 12 ~ 32 Volts DC (Auto sensing) | Quiescent Current: 12 milliamps (with backlight off) Backlight Reverse polarity protected | Network cable length = 1000m | Voltage & EMI protected Data retention: 50 years (without power) Smart Switch | PO Box 272 | Waika

 Open the catalog to page 1

All Smart Switch Technologies catalogs and brochures

  1. SEN-S/S100

    1  Page

  2. NV-8000

    1  Page

  3. SMF-001

    1  Page

  4. BC-8000

    1  Page

  5. FR-4000

    1  Page

  6. FR-8000

    1  Page

  7. TD-4000

    1  Page

  8. TC-8000

    1  Page

  9. TM-4000

    1  Page

  10. FS-2A

    1  Page

  11. FC -006

    1  Page

  12. SMS-2

    1  Page

  13. SMS8

    1  Page

  14. PR-100

    1  Page

  15. SM-420

    1  Page

  16. SM-180

    1  Page

  17. FC - 8000

    1  Page

  18. AM 100

    1  Page

  19. NAV-8

    1  Page

  20. FS 2A

    1  Page

  21. SEN 100

    1  Page

  22. IF 100

    1  Page

  23. NMEA 0183

    1  Page

  24. ST 660

    1  Page

  25. NV 2000

    1  Page

  26. NV 8000

    1  Page

  27. FR 8000

    2  Pages

  28. TM 4000

    1  Page

Archived catalogs

  1. BSW 1000

    1  Page

  2. TD 4000

    1  Page

  3. AL 8000

    1  Page

  4. TC 8000

    1  Page

  5. BC 8000

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.