FC - 8000

FC - 8000

Product catalog summary
Specifications:
  • Supply Voltage: 12 ~ 32 Volts DC (Auto sensing)
  • Quiescent Current: 12 Milliamps (with backlight off)
  • Backlight: Reverse polarity protected
  • Network cable length: 1000m
  • Voltage & EMI Protected
System Overview:

The FC-8000 Controller is designed for monitoring and transferring fuel across up to eight tanks. It supports a networked solution with a maximum cable length of 1000 meters. The system includes the FC-8000 display controller, up to eight FC-100 tank controllers, and optional RF-800 repeater displays.

FC-8000 Display Controller Features:
  • Centralized control for tank monitoring and transfer
  • Transfer capability between any tanks
  • Control of AC or DC transfer pumps
  • Visual and audible alarms for tank levels and faults
  • Displays measurements in Litres, Gallons, and Percentage
  • Programmable tank names for location and type identification
RF-800 Remote Display Unit:

The RF-800 is an optional monitoring-only display unit. Up to three units can be installed for convenient monitoring throughout the vessel.

Controllers:
  • FT-100 Fuel Controller: Manages fuel tank solenoid valves and includes a fluid level sensor input.
  • HB-200 Controller: Used for fresh, grey, or black tanks with a fluid level sensor input.
  • HB-200/P Controller: Similar to HB-200 but includes a pump output.
System Layout:

The system allows for any combination of FT-100, HB-200, or HB-200/P controllers (up to eight) and any number of RF-800 repeater displays. The layout supports monitoring and control from a single location, with devices connected via a two-core bus cable.

See more

Catalog excerpts

FC - 8000-1

Part No: FC - 8000 Actual Size = 126 x 116 x 21mm Fuel Tank Controll THE FC - 8000 EIGHT CHANNEL HOLDING TANK CONTROLLER SYSTEM LAYOUT FOR MODEL FC-8000 Any combination of FT-100, HB-200 or HB-200/P (up to eight) can be connected plus, any number of repeater displays (model RF-800). Eight Channel Fuel Tank Controller System Layout for Model FC-8000. Monitor and Control up to 8 tanks from one location. Transfer screen The FC-8000 Controller provides an intelligent networked solution for the monitoring and transferring fuel from or to (up to) eight tanks. The diagram (right) shows a typical system layout. The system consists of the FC-8000 display controller (as seen above) up to eight FC-100 tank controllers and any number of optional RF-800 repeater displays communicating via a 2-wire network cable with a maximum cable length of 1000 meters. 280 Lts 700 Lts Note: The system can monitor and control up to eight tanks. The eight tanks can be any combination of fuel, fresh, grey or black. Any FT-100 controller or controller’s may be replace with either a HB-200 or HB-200/P if Any device can sit anywhere on this two core Bus cable. either a fresh, grey or black tank or tanks would like to be monitored instead of fuel. Only fuel may be transferred. Model RF - 800 Up to three remote displays may be tted FC- 8000 DISPLAY CONTROLLER: Is a powerful tank monitor and control system. • Full control from one central location on your boat. • Transfer from any tank to any tank. Model FC - 8000 Tank Controller FT - 100 Tank Controller FT - 100 • Control either AC or DC or both transfer pumps Tank Controller FT - 100 • Visual indication of tank level Solenoid Valve Bottom • Visual & audible tank full and fault alarms. Solenoid Valve Bottom Solenoid Valve Top • Displays in Litres or Gallons and Percentage. Solenoid Valve Bottom Solenoid Valve Top Solenoid Valve Top DC Pump Controller DC- P100 • All tanks are name programmable giving tank location and type, e.g. Aft Port, Grey Tank. Blue = 2 Core Data Cable RF-800 REMOTE DISPLAY UNIT: The RF-800 Repeater Display is an optional extra.RF-800 is for monitoring only and will not allow control. Up to three units may be connected throughout the vessel for convenient tank monitoring. Note: The FT-100 FUEL CONTROLLER: This controller is used to manager the fuel tanks Solenoid valve’s (top & bottom) the safty top switch and provides an input for the uid level sensor. AC Pump Controller AC - P200 Battery Tank Controller FT - 100 Tank Controller FT - 100 Tank Sensor Solenoid Valve Bottom HB-200 CONTROLLER: Solenoid Valve Top Tank Controller FT - 100 Tank Sensor Solenoid Valve Bottom Solenoid Valve Top Tank Sensor Solenoid Valve Bottom Solenoid Valve Top Tank Controller FT - 100 Tank Controller FT - 100 Tank Sensor Solenoid Valve Bottom Solenoid Valve Top This controller is used for other tanks eg. Grey or Black and provides an input for the uid level sensor and a pump output. Pump Tank Sensor Solenoid Valve Bottom Solenoid Valve Top This controller is used for other tanks eg. Fresh, Grey or Black and provides an input for the uid level sensor. HB-200/P CONTROLLER: Pump Supply Voltage: 12 ~ 32 Volts DC (Auto sensing) | Quiescent Current: 12 Milliamps (with backlight off) Backlight Reverse polarity protected | Network cable length=1000m | Voltage & EMI Protected AC Supply

 Open the catalog to page 1

All Smart Switch Technologies catalogs and brochures

  1. SEN-S/S100

    1  Page

  2. NV-8000

    1  Page

  3. SMF-001

    1  Page

  4. BC-8000

    1  Page

  5. FR-4000

    1  Page

  6. FR-8000

    1  Page

  7. TD-4000

    1  Page

  8. TC-8000

    1  Page

  9. TM-4000

    1  Page

  10. FR-1600

    1  Page

  11. FS-2A

    1  Page

  12. FC -006

    1  Page

  13. SMS-2

    1  Page

  14. SMS8

    1  Page

  15. PR-100

    1  Page

  16. SM-420

    1  Page

  17. SM-180

    1  Page

  18. AM 100

    1  Page

  19. NAV-8

    1  Page

  20. FS 2A

    1  Page

  21. SEN 100

    1  Page

  22. IF 100

    1  Page

  23. NMEA 0183

    1  Page

  24. ST 660

    1  Page

  25. NV 2000

    1  Page

  26. NV 8000

    1  Page

  27. FR 8000

    2  Pages

  28. TM 4000

    1  Page

Archived catalogs

  1. BSW 1000

    1  Page

  2. TD 4000

    1  Page

  3. AL 8000

    1  Page

  4. TC 8000

    1  Page

  5. BC 8000

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.