AL 8000
1Pages

{{requestButtons}}

Catalog excerpts

AL 8000 - 1

Alarm Monitor Al 8000 Actual Size = 126 x 116 x 21mm Alarm Monitor Al 8000 SYSTEM OVERVIEW The AL-8000 Alarm Monitor has been developed to allow monitoring of up to 32 different inputs. It is a network system consisting of the AL-8000 Master Display Unit and up to four AL-100 Input Units located anywhere on the vessel. Monitor up to 32 alarms from one location. The AL-8000 alarm monitor provides an intelligent networked solution for the monitoring up to 32 different alarms.The diagram (right) shows a typical system layout. The system consists of the AL-8000 display controller (as seen above), up to four AL-100 units and one (optional) repeater display. Communication to these is via a 2-wire network cable with a maximum cable length of 1000 meters. In addition and as an option, the RA-800 Remote Display Unit may be added to provide fault status anywhere on the vessel. The Master Display Unit (MDU) controls communication with all attached Input Units. System components may be located anywhere on the network cable and the cable may be up to 1000 meters in length. These features are unique to the AL-8000 and provide maximum flexibility to locate components onboard the vessel while minimising wiring costs. All devices are interconnected by a 2-wire network cable similar to that used for telephone installations. AL-8000 DISPLAY CONTROLLER: Is the master display unit. • Visual & audible alarm for any fault condition. • 4 x overrides (engine running overrides for engine alarms). Builders and retrofitters can now offer reasonably priced systems, while providing boat owners with outstanding visibility into conditions in their bilge areas, allowing a variety of control options under both normal and off-normal conditions. • 8 inputs have programmable delays (5 seconds to 10 minutes). • All alarms tone programmable (with tone or without tone or repeating tone). • Alarms are name programmable e.g. (High Bilge) (Engine Room Fire) (Oil Pressure) (Water in Fuel). AL-100: Input module. 2 WIRE NETWORK (STANDARD TELEPHONE WIRE) • Eight inputs. • Each input can be set for normally open & closing to +vdc on fault - 2k2 line resistor for supervised line AL 100 UP TO 4 INPUT UNITS AL 100 - normally open & closing ground on fault - normally ground & opening on fault • One relay output = 3 amp inductive:closes on any fault. AL 8000 MDU RELAY OUTPUT 8 INPUTS RD-800: The RD-800 Repeater Display is an optional extra and may be connected anywhere on the vessel for convenient monitoring. ORDER INFORMATION Supply Voltage: 12 ~ 32 Volts DC (Auto sensing) | Quiescent Current: 26 Milliamps (with backlight off) Reverse polarity protected | Network cable length =1000m | Voltage & EMI Protected Programmed Data Retention: 50 years (without power) | Backlight PART NUMBER: 4720093 AL-8000 4720095 AL-100 4720096 RA-800 PRODUCT DESCRIPTION: EIGHT-CHANNEL ALARM CONTROLLER ALARM INPUT CONTROL MODULE REMOTE DISPLAY *SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE. RELAY OUTPUT 8 INPUTS RA 800 REMOTE DISPLAY

Open the catalog to page 1

All Smart Switch Technologies catalogs and brochures

  1. SEN-S/S100

    1 Pages

  2. NV-8000

    1 Pages

  3. SMF-001

    1 Pages

  4. BC-8000

    1 Pages

  5. FR-4000

    1 Pages

  6. FR-8000

    1 Pages

  7. TD-4000

    1 Pages

  8. TC-8000

    1 Pages

  9. TM-4000

    1 Pages

  10. FR-1600

    1 Pages

  11. FS-2A

    1 Pages

  12. FC -006

    1 Pages

  13. SMS-2

    1 Pages

  14. SMS8

    1 Pages

  15. PR-100

    1 Pages

  16. SM-420

    1 Pages

  17. SM-180

    1 Pages

  18. FC - 8000

    1 Pages

  19. AM 100

    1 Pages

  20. NAV-8

    1 Pages

  21. FS 2A

    1 Pages

  22. SEN 100

    1 Pages

  23. IF 100

    1 Pages

  24. NMEA 0183

    1 Pages

  25. ST 660

    1 Pages

  26. NV 2000

    1 Pages

  27. NV 8000

    1 Pages

  28. FR 8000

    2 Pages

  29. TM 4000

    1 Pages

Archived catalogs

  1. BSW 1000

    1 Pages

  2. TD 4000

    1 Pages

  3. TC 8000

    1 Pages

  4. BC 8000

    1 Pages