Product catalog summary
Overview: The document describes a mini-PLC based stand-alone, shipborne alarm system designed to comply with IMO regulations and classification society requirements, such as SRtP (Safe Return to Port). The system is controlled by a central unit and can integrate with existing alarm and monitoring logic. It features innovative microprocessor technology for sound generation, offering multiple acoustic philosophies with sound levels up to 120dB(A).
Alarm System Features: The system provides visual alarms through rotating or flashing lights and LED triangular indicators with explicit symbols for specific alert types. A standard signal light column includes six or seven alarm indicators, customizable to specific needs. The control unit is compact, easy to install, and requires only one power supply.
Sound Module: The Acoustic Generator Module (AGM) is a compact sound module mounted on a TS35 terminal rail inside each alarm column. It includes a 40W digital amplifier and a RISP processor generating 64 maritime-specific sound characteristics. The module supports a 'soft start' feature, gradually increasing sound levels to protect personnel in low noise environments.
System Composition: The typical system includes multiple control units and light signal devices, with dry n/o contacts from corresponding systems to indicate system failures. The dual control unit application meets SRtP requirements.
Periphery Equipment: Various models of LSD standard columns and dynamic acoustics control units are listed, along with specific alarm indicators for different scenarios such as CO2, fire, and toxic gas alarms. The document also lists triangular light kits and symbols for various alarms.
Additional Features: The Light Signal Control Unit is available with a Power Source Detection Module (PSDM). The document provides part numbers for various components and accessories, including indicator panels for console mounting and specific alarm types.
See more

Catalog excerpts

Signal Light Column (LSAS)-1

APPLICATION compact design of control unit easy to install digital sound processing On one hand visual alarms are indicated by rotating lights or flash lights and on the other hand explicit symbols on LED triangular indicators are advising the specific alert type. A standard signal light column consists of six or seven alarm indicators (symbols). In case a different amount of alarm indicators is needed, the signal light column can easily be adapted to your specific requirements. only one power supply required: DATA & FEATURES (control unit) LIGHT SIGNAL ALARM SYSTEM The signal light column is a mini-PLC based stand-alone, shipborne alarm system to indicate visual and audible alarms according to IMO regulations as well as classification society requirements (e.g. SRtP - Safe Return to Port). Controlled by a central unit the signal light column alarm system can also be adapted to your existing alarm and monitoring logic. The sound generation is based on an innovative microprocessor technology and offers multiple acoustic philosophies with up to 120dB(A) sound level. TYPICAL SYSTEM COMPOSITION PERIPHERY EQUIPMENT dual control unit application to meet SRtP requirements Light Signal Device Light Signal Device ACOUSTIC GENERATOR MODULE AGM dac A compact sound module to be mounted on TS35 terminal rail inside each alarm column is based upon a 40W digital amplifier unit. A RISP processor is generating 64 maritime specific sound characteristics which can be allocated individually to 9 physical input channels. That world wide unique module allows audible minor alarms to start with a reduced sound level increasing automatically to the maximum level within a defined period. This „soft start“ will help raise health and safety levels for personnel working in low noise level environments that do not require ear protection (main engine has been stopped) and where standard alarm systems generating maximum sound levels that could damage hearing. SOUND LEVEL 70 - 110dB PERIPHERY EQUIPMENT PERIPHERY EQUIPMENT LSD DYNAMIC ACOUSTICS CONTROL LSD 209.6x.2x.1x0 PERIPHERY EQUIPMENT LSD 309.10x.2x.1x0 LIGHT SIGNAL CONTROL UNIT also available with PSDM (Power Source Detection Module) PERIPHERY EQUIPMENT 770295 INDICATOR PANEL FOR CONSOLE MOUNTING SHIPS ALARM INDICATOR 999770 PERIPHERY EQUIPMENT TRIANGULAR LAMP SET TRIANGULAR LIGHT SYMBOLS FIRE ALARM TELEPHONE CALL FOAM ALARM NOVEC ALARM WATER MIST COLD STORE ALARM GENERAL ALARM HOSPITAL CALL ENGINEER CALL BRIDGE ALARM STEERING GEAR WATCH ALARM BILGE ALARM SPRINKLER ALARM INDIVIDUAL SYMBOL (on request) ABANDON SHIP INTERCOM CALL