SIGMAGUARD 425

SIGMAGUARD 425

SIGMAGUARD 425

Product catalog summary
Description: SIGMAGUARD 425 is a two-component, solvent-free, polyamine-cured epoxy coating designed for long-term protection of ballast tanks and steel structures. It offers excellent resistance to corrosion and seawater, suitable for block stage application, and reduces explosion risk and fire hazard in confined spaces. It can be applied using single feed airless spray equipment and is available in grey and green gloss colors.
Principal Characteristics: The coating has a mass density of 1.4 g/cm³ and volume solids of 98 ± 2%. It complies with VOC regulations, with a maximum of 47 g/kg and 66 g/l. The recommended dry film thickness is 250 µm, with a theoretical spreading rate of 3.9 m²/l. Touch dry time is 12 hours, with an overcoating interval of 24 hours minimum and 7 days maximum. The shelf life is at least 12 months in a cool and dry place.
Recommended Substrate Conditions and Temperatures: The substrate should be dry and free from contamination, with a temperature above 5°C and at least 3°C above the dew point. Maximum relative humidity during application and curing is 80%.
System Specification and Instructions for Use: The mixing ratio by volume is 80:20 (base to hardener), with a minimum mixing temperature of 20°C. No thinner should be added. For airless spray application, use heavy-duty equipment with a 60:1 pump ratio. The recommended nozzle orifice is 0.53 mm, with a minimum nozzle pressure of 28 MPa at 20°C.
Safety Precautions: Use a fresh air mask and gloves during spraying, and ensure adequate ventilation in confined spaces. Clean all equipment immediately after use, and refer to safety sheets for paint and recommended thinners.
Additional Data: The dry film thickness cannot be measured immediately due to low initial hardness. Overcoating and curing tables provide specific intervals based on substrate temperature. Pot life varies with temperature, and exothermic reactions may increase temperature during pot life.
References: For further information, refer to information sheets 1411, 1430, 1431, 1433, 1434, and 1490. The document emphasizes the user's responsibility to determine product suitability and notes that the English text prevails over translations.
See more

Catalog excerpts

SIGMAGUARD 425-1

SIGMAGUARD 425 4 pages DESCRIPTION January 2008 Revision of September 2005 two component solvent free polyamine cured epoxy coating PRINCIPAL CHARACTERISTICS – provides long term protection for ballast tanks and steel structures, with excellent resistance against corrosion and seawater – suitable for block stage application – good edge covering capacity – reduces explosion risk and re hazard in conned spaces – can be applied by single feed airless spray equipment COLOURS AND GLOSS grey, green - gloss BASIC DATA AT 20°C (1 g/cm³ = 8.25 lb/US gal; 1 m²/l = 40.7 ft²/US gal) (data for mixed product) Mass density Volume solids VOC (supplied) 1.4 g/cm³ 98 ± 2% max. 47 g/kg (Directive 1999/13/EC, SED) max. 66 g/l (approx. 0.6 lb/gal) see information sheet 1411 250 µm 3.9 m²/l fo 250 µm * 12 hours * min. 24 hours * max. 7 days * Recommended dry lm thickness Theoretical spreading rate Touch dry after Overcoating interval (data for components) Shelf life (cool and dry place) at least 12 months * see additional data RECOMMENDED SUBSTRATE CONDITIONS AND TEMPERATURES – previous coat; dry and free from any contamination – substrate temperature should be above 5°C and at least 3°C above dew point – maximum relative humidity during application and curing is 80% – dust quantity rating "1" for dust size class "3", "4" or "5", lower dust size classes to be removed if visible on the surface to be coated without magnication (ISO 8502-3:1992) SYSTEM SPECIFICATION marine INSTRUCTIONS FOR USE mixing ratio by volume: base to hardener 80 : 20 system sheet: 3106 (spec. 7) – when mixing the temperature of the base and hardener should be at least 20°C – at lower temperature the viscosity will be too high for spray application – no thinner should be added page 1/4

 Open the catalog to page 1
SIGMAGUARD 425-2

SIGMAGUARD 425 January 2008 Induction time none Pot life approx. 1 hour at 20°C * * see additional data AIRLESS SPRAY Recommended thinner Nozzle orice Nozzle pressure – use heavy duty single feed airless spray equipment preferably 60:1 pump ratio and suitable high pressure hoses – in-line heating or insulated hoses may be necessary to avoid cooling down of paint in hoses at low air temperature – the paint lines should be as short as possible no thinner should be added approx. 0.53 mm (= 0.021 in) at 20°C (paint temperature) min. 28 MPa (= approx. 280 bar; 4000 p.s.i.) at 30°C (paint temperature)...

 Open the catalog to page 2
SIGMAGUARD 425-3

SIGMAGUARD 425 January 2008 measuring dry lm thickness – because of low initial hardness the dft cannot be measured for some days (depending on ambient temperature) after application due to the penetration of the measuring device into the paint lm – the dft should be measured using a calibration foil of known thickness placed in between the coating and the measuring device Overcoating table for SigmaGuard 425 for dft up to 250 µm (for spot repair and stripe coating only) with itself substrate temperature 5°C 10°C 20°C 30°C 40°C minimum interval 3 days 48 hours 24 hours 16 hours 12 hours maximum...

 Open the catalog to page 3
SIGMAGUARD 425-4

SIGMAGUARD 425 January 2008 REFERENCES Explanation to product data sheets see information sheet 1411 Safety indications see information sheet 1430 Safety in conned spaces and health safety Explosion hazard - toxic hazard see information sheet 1431 Safe working in conned spaces see information sheet 1433 Directives for ventilation practice see information sheet 1434 Cleaning of steel and removal of rust see information sheet 1490 PPG Protective & Marine Coatings Ballast Tank Working Procedure New Building LIMITATION OF LIABILITY The information in this data sheet is based upon laboratory tests...

 Open the catalog to page 4
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.