
Catalog excerpts

February 2013 Revision of March 2011 two component solvent free amine cured novolac phenolic epoxy coating PRINCIPAL CHARACTERISTICS – one coat tank coating system – clear version for glassmat reinforced solvent free tank bottom system (see system sheet 4145) – excellent resistance to crude oil up to 90°C – suitable for storage of unleaded gasolines – good chemical resistance against a wide range of chemicals and solvents – good visibility due to light colour – glossy and smooth appearance – easy to clean – can be applied by heavy duty single feed airless spray equipment (60:1) – reduced explosion risk and re hazard – approved to Air BP F2D2 section 2.1 for the storage of jet fuels COLOURS AND GLOSS green, cream, clear – gloss (1 g/cm³ = 8.35 lb/US gal; 1 m²/l = 40.7 ft²/US gal) (data for mixed product) Full cure after 1.3 g/cm³ 100% max. 106 g/kg max. 142 g/l (approx. 1.2 lb/gal) 73 g/ltr (0.6 lb/gal) (by EPA Method 24) see information sheet 1411 300 - 600 μm depending on system 3.3 m²/l for 300 μm * 6 hours at 20°C min. 24 hours * max. 2 months * 5 days * at 20°C Shelf life (cool and dry place) (data for components) at least 12 months Mass density Volume solids VOC (Supplied) VOC (EPA Method 24) Recommended dry lm thickness Theoretical spreading rate Touch dry after Overcoating interval RECOMMENDED SUBSTRATE CONDITIONS AND TEMPERATURES – steel; blast cleaned to a minimum of ISO-Sa2½, blasting prole 50 - 100 μm – substrate temperature must be above 5°C and at least 3°C above dew point during application and curing – steel with suitable primer (SigmaGuard 260) which must be dry, clean and free from any contamination
Open the catalog to page 1
mixing ratio by volume: base to hardener 80 : 20 Induction time Pot life – the temperature of the mixed base and hardener should preferably be at least 20°C – at lower temperature the viscosity will be too high for spray application – no thinner should be added – for recommended application instructions: see working procedure none 1 hours at 20°C * *see additional data AIRLESS SPRAY Recommended thinner Nozzle orice Nozzle pressure use heavy duty single feed airless spray equipment preferably 60:1 pump ratio and suitable high pressure hoses/in -line heating or insulated hoses may be...
Open the catalog to page 2
measuring dry lm thickness – because of low initial hardness the dft cannot be measured within some days due to the penetration of the measuring device into the soft paint lm – the dft should be measured using a calibration foil of known thickness placed in between the coating and the measuring device Overcoating with Novaguard 840 (spot repair and stripe coating) substrate temperature minimum interval maximum interval – surface should be dry and free from any contamination Curing Curing table substrate temperature 5°C 10°C 20°C 30°C dry to handle 60 hours 30 hours 16 hours 10 hours full...
Open the catalog to page 3
Pot life (at application viscosity) 20°C 30°C – due to exothermic reaction, temperature during and after mixing may increase Worldwide availability It is always the aim of PPG Protective and Marine Coatings to supply the same product on a worldwide basis. However, slight modication of the product is sometimes necessary to comply with local or national rules/circumstances. Under these circumstances an alternative product data sheet is used Safety indications Safe working in conned spaces Cleaning of steel and removal of rust Explanation to product data sheets Safety in conned spaces and...
Open the catalog to page 4
WARRANTY PPG warrants (i) its title to the product, (ii) that the quality of the product conforms to PPG’s specications for such product in effect at the time of manufacture and (iii) that the product shall be delivered free of the rightful claim of any third person for infringement of any U.S. patent covering the product. THESE ARE THE ONLY WARRANTIES THAT PPG MAKES AND ALL OTHER EXPRESS OR IMPLIED WARRANTIES, UNDER STATUTE OR ARISING OTHERWISE IN LAW, FROM A COURSE OF DEALING OR USAGE OF TRADE, INCLUDING WITHOUT LIMITATION, ANY OTHER WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE OR USE,...
Open the catalog to page 5All Sigma Coatings PPG PMC catalogs and brochures
-
SIGMAGLIDE® 890
2 Pages
-
PPG STEELGUARD™
5 Pages
-
PPG PSX® 700
5 Pages
-
SIGMAPRIME
8 Pages
-
PPG Hydroelectric power
4 Pages
-
PPG HI-TEMP 900
2 Pages
-
PPG FPSO
4 Pages
-
PPG Fossil power
4 Pages
-
PPG Drill ships
4 Pages
-
PITT-CHAR® XP
5 Pages
-
AMERSHIELD®
4 Pages
-
AMERLOCK® SERIES
4 Pages
-
AMERCOAT 240 SERIES
4 Pages
-
SIGMACOVER 280
7 Pages
-
SIGMAWELD™ 120
4 Pages
-
SIGMASHIELD 1200
5 Pages
-
PSX® 700
8 Pages
-
AMERCOAT 205
5 Pages
-
AMERCOAT 114 A
5 Pages
-
ABC 4
4 Pages
-
ABC 3
4 Pages
-
AMERCOAT 242 HB
6 Pages
-
AMERCOAT 242
6 Pages
-
AMERCOAT 238
6 Pages
-
AMERCOAT 237 M
5 Pages
-
AMERCOAT 138 G
5 Pages
-
SIGMASHIELD 1090
5 Pages
-
SIGMASHIELD 1200
5 Pages
-
SIGMATHERM 500
3 Pages
-
SIGMAWELD 165
5 Pages
-
SIGMAWELD 190
5 Pages
-
SIGMATHERM 540
3 Pages
-
SIGMA ECOFLEET® 690
2 Pages
-
PHENGUARD 935 EN
5 Pages
-
SIGMA ALPHAGEN 240 EN
5 Pages
-
SIGMACOVER 435 EN
6 Pages
-
SIGMADUR 580 EN
4 Pages
-
SIGMAGUARD 720 EN
4 Pages
-
SIGMADUR ONE
3 Pages
-
SIGMAGLIDE 990
3 Pages
-
SIGMAGUARD CSF 650
6 Pages
-
SIGMARINE 42
2 Pages
-
SIGMAZINC 102
4 Pages
-
SIGMAWELD 199
4 Pages
-
SIGMA VIKOTE 18
3 Pages
-
SIGMATHERM 175
2 Pages
-
SIGMASHIELD 420 LT
4 Pages
-
SIGMARINE 28
3 Pages
-
SIGMAGUARD 425
4 Pages
-
SIGMA ECOFLEET 238 A
3 Pages
-
SIGMADUR 500US
4 Pages
-
SIGMACOVER 520
4 Pages
-
SIGMACOVER 380
4 Pages
-
SIGMA AQUACOVER 45
3 Pages
-
SIGMA ALPHAGEN 230
5 Pages
-
PHENGUARD 930
5 Pages