RCS® Remote Control Systems Push/Pull Cables • Control Levers • Pedals • Pull Only Cables Edition 2016/2017 RINGSPANN® Registered Trademark of RINGSPANN GmbH, Bad Homburg RCS® Registered Trademark of RINGSPANN RCS GmbH, Obe

 Open the catalog to page 1

RCS® Remote Control Systems Control lever systems Push/Pull cables Setup and description of push/pull cables Overview of push/pull cables Basic cable series Selection of cable sizes Efficiencies and bend radii Connection type T of cable end parts Accessories for control lever 46/58 Connection type G of cable end parts Accessories for control lever 58.5 Connection type R or S of cable end parts Accessories for friction control 22.x Codes of practice and health and safety regulations Assembly information Order key for push/pull cables for control lever systems Order key for push/pull cables...

 Open the catalog to page 2

Setup and description of push/pull cables Setup A flat wire-reinforced inner member is located in a conduit, which is formed by an inner-lying inner tube and specially arranged longitudinal wires (linear wire stranding). The linear wires on the other hand (with the exception of types 770) are supported and fixed by a support wire winding. A plastic extrusion is doing the outer coverage of the conduit. For the universal connection of elements, the inner member and conduit are supported with pressed on zinccoated or stainless steel end parts. The push/pull cables are designed lightly gliding...

 Open the catalog to page 3

Overview of push/pull cables

 Open the catalog to page 4

Cable series the basis of Remote Control System Our cable series are offered in five sizes. In the standard version, three end part configurations are designed. There are six different types of tra- vel, which can be combined with three different seals. A multitude of additional possibilities for configuration and variation in the setup of the cables are possible in order to create a solution that fits to the respective application. Series 383 and 384 • Series 383 with zinc-coated end parts and stainless steel rod ends • Series 384 with stainless steel end parts • PTFE-covered inner member...

 Open the catalog to page 6

Cable series RINGSPANN the basis of Remote Control System - Series 275 with zinc-coated end parts and stainless steel rod ends Series 274 with stainless steel end parts Inner member stainless steel reinforced Highly efficient Remarkably small bend radii Extremely smooth High travel frequencies Colour: blue For cable sizes U,V,LandM High temperature range from • Series 775 with zinc-coated end parts and stainless steel rod ends • Series 774 with stainless steel end parts • Attractive pricing • Highly efficient • For applications without special • Colour: black • For cable sizes U, Land M •...

 Open the catalog to page 7

Standard end parts Connection types of cable end parts, wiper seals and lubrication Connection types of cable end parts Rigid screw endfitting type S and R Swiveled bulkhead endfitting type T Swiveled clamp endfitting type G Wiper seals Seal no. 05 The rubber wiper seal has been proven for all cable sizes for normal applications in the entire machine construction. Upon request also with a support tube from stainless steel. Automatic self-adjusting PTFE wiper seal in case of wear for cable sizes U, V and L. Protects well against fine dust. Design like seal no. 10 with additional double...

 Open the catalog to page 8

Selection of cable sizes Cable sizes, maximum travel, bend radii, seals, thread rod ends, outer diameter of conduits and push and pull forces depending on the travel Cable sizes, maximum travel, bend radii, seals, thread rod ends and outer diameter of conduit Cable size Bend radius for cable series Outer diameter of conduit for cable series Push and pull forces depending on the travel The specified forces are applicable for use in permanent operation with a long service life. A safety factor of 1.5 can be used to calculate the temporary overloads. Pull forces diagram 4 000 Push forces...

 Open the catalog to page 9

Efficiencies and bend radii Efficiencies The efficiency of a push/pull cable (the relation of the required cable operating force to a given output force) is particularly influenced by the number of bends laid in the cable. The cable operating force can be calculated in accordance with the following formula: Operating force = Output force x Efficiency factor α is the sum of all cable bends in degrees. In addition to the cable bends, the cable length is to be taken into consideration with 15° for every 1 meter. Bend radii The laying radii for push/pull cables should be selected as generously...

 Open the catalog to page 10

Connections of cable end parts Connection type T Swiveled bulkhead endfitting Cable size Dimensions A Cable size Push/pull cables* at travel of 25 mm Cable with hand operation** NL/TL (1)/MA TL (2) 25 51 76 38 mm mm mm mm * Rod end in mid position ** Rod end completely moved out (see from page 22), TL (1) = variant 1, TL (2) = variant 2 (see page 25) *** Rod end in mid position (see from page 32) The rubber wiper seal is suited to all cable sizes in all normal applications. Support tubes, along with end parts are available in stainless steel if required. Can also be supplied with end parts...

 Open the catalog to page 11

Connections of cable end parts Connection type G Swiveled clamp endfitting Cable size Dimensions A Cable size Push/pull cables* at travel of 25 mm Cable with hand operation** NL/TL (1)/MA TL (2) 25 51 76 38 mm mm mm mm Can also be supplied with end parts made from stainless steel. * Rod end in mid position ** Rod end completely moved out (see from page 22), TL (1) = variant 1, TL (2) = variant 2 (see page 25) *** Rod end in mid position (see from page 32) Cables for operating level*** 14RN15 mm

 Open the catalog to page 12

Connections of cable end parts Connection type R or S Rigid screw type endfitting Cable size Dimensions A Cable size Push/pull cables* at travel of 25 mm Cable with hand operation** NL/TL (1)/MA TL (2) 25 51 76 38 mm mm mm mm Cables for operating level*** * Rod end in mid position ** Rod end completely moved out (see from page 22), TL (1) = variant 1, TL (2) = variant 2 (see page 25) *** Rod end in mid position (see from page 32) **** only for hand operation TL and MA, not available for NL Dimensions D for cable size and travel: Cable size Dimensions E for cable size L and travel: Cable...