SENECT AQUACULTURE|CONTROL PRO - 1

A Q UACULTURE |C ON T R OL Multi functional power aquaculture controller • Sensor-based control (up to 6 sensors in one unit) • Versatile output ports: 24 V DC, 4-20 mA, 0-10 V DC, 230 V AC • Intelligent feeder and drum-filter control • WLAN: alarm and surveillance online TEMP. CONTROL

Open the catalog to page 1
SENECT AQUACULTURE|CONTROL PRO - 2

A Q UA C U LT U R E | C O N T R O L Multifunctional power aquaculture controller Why using control technology at all? There are many reasons, why people use measurement and control technology in aquaculture. Besides an enhanced security created by an surveillance system, and beside the cost savings by using water, feed, oxygen or electricy efficiently, the creation of optimal condidtions for the fish is often the main reason for installing control technology. That´s also because perfect conditions are a prerequisite for healthy fish, which can fully use their growth potential. Security...

Open the catalog to page 2
SENECT AQUACULTURE|CONTROL PRO - 3

connected sensor systems No compromises - the controller for all applications In the AQUACULTURE|CONTROL-series, there are two basic types: the „Basic“ and the „Pro“. Both types can be either bought with an 150 W or an 300 power adaptor. AQUACULTURE|CONTROL Basic 3 Sensor-input ports 3 Actuator-output ports 3 Schuko-230 V AC outputs Pro 6 Sensor-input ports 6 Actuator-output ports 3 Schuko-230 V AC outputs Powerful hardware - Every type of Senect Sensor can be connected (e.g. O2, pH, ORP, water level,...) - Versatile actuator output ports with 24 V DC PWM, 4 - 20 mA, 0 - 10 V DC -->...

Open the catalog to page 3
SENECT AQUACULTURE|CONTROL PRO - 4

A Q UA C U LT U R E | C O N T R O L Multifunctional power aquaculture controller Application example: AQUACULTURE|CONTROL Basic for an hatchery By using the AQUACULTURE|CONTROL Basic with only some sensors and actuators, you can not only monitor and surveill your hatchery - you can also regulate the most important parameters. For example: - in case of low oxygen values, - the solenoid valve can be switched on and the oxygenation starts - the feeding can be stopped until the oxygen concentration is again above the lower limit - the blocking of the outlet sieve can be recognized - by...

Open the catalog to page 4
SENECT AQUACULTURE|CONTROL PRO - 5

connected sensor systems Application example: AQUACULTURE|CONTROL Pro for a recirculation system With the AQUACULTURE|CONTROL Pro up to 6 sensorss, 6 actuators and three 230 V consumers can be directly connected. That´s why you can also with only one control unit control all important processes in a small RAS. And for larger systems, you can simply use several control units. Solenoid valve (water) Drum filter Circulation pump Feeder Solenoid valve for oxygen Oxygen sensor Example: Complete control of a reciculation system with only one control unit. +49 (0) 6341 - 95 95 210 info@senect.de...

Open the catalog to page 5
SENECT AQUACULTURE|CONTROL PRO - 6

connected sensor systems AQUACULTURE|CONTROL Basic / Pro Dimensions: Power consumption of unit: max. 8-18 W (without plugged consumers) Sensor-input ports: Basic: 3 x Sensor / Pro: 6 x Sensor Output ports: 1 x High-Power motor-output (24 V, max. 5/10 A) Basic: 2 x Actuators / Pro: 5 x Actuators 3 x 230 V AC, individually fused Ingress protection: Data transmission: Equipment (examples): Sensor water level probe PS (PS-300-MA) DS S A Q C- A 1- 18 0 EN Versi o n: 1. 0 Stat us: rel e ased , su bje ct to alt erat ion s Sensor Oxygen O2S (O2S-20-SC) Sensor pH - XR1 (PH-410-XR1-SC) Power Switch...