Catalog excerpts
= jppn=orccJkbh k POSITIVELY COMPENSATED (60 PSI OVER AMBIENT), DEEPWATER MUX CABLE CONNECTOR jppn=orccJkbh=terminated to electro-optical MUX cable DESCRIPTION The jppn=orccJkbh connector is a MUX cable termination that maintains a constant positive pressure inside its oilfilled connector cavity. Positive pressure, maintained at 60 psi using a spring-loaded piston, deters water ingress from conductor interstices and other sources. Inside the connector, advanced conductor booting technology assures functionality even when the jppn= orccJkbh is water-flooded. The jppn= orccJkbh is field installable and testable. Dual static barrier seals are used throughout the connector. It is currently available in both all electric and electro optic hybrid configurations. KEY FEATURES · Overall Length: 24.2" · Overall Diameter: 4.75" · Megger Test Pin allows testing for water-flooding while mated · Test port for mating o-rings · Depth Rating: 15,000 ft. · Modular cable terminations and Field Installable (no compounds) · Pressure Compensated Chamber OPERATION · Design life: 20 years · Qualification tested to 8,400 psi. Design pressure: 20,000 psi · Secondary seals on contacts allow for operation even water flooded · Conductor Insulation Resistance: >500 Megohms @ 500 VDC · Cable Pullout Load: 700 lbs, <1.0 dB attenuation · Qualification tested in ice bath, chamber water-filled, then oil-filled MATERIALS · 15-5 PH SST, 316 SST, 17-4 PH SST, CA630, Titanium Grade 5 · Electrical and elctro-optical inserts: Glass Reinforced Epoxy · Elastomer: Neoprene, Nitrile · Compensation Fluid: DC200 or DC710 non conductive silicone oil pb^`lk Advanced Products, LLC. May 2011 1321 Nelius Road, PO Box 767, Bellville, Texas 77418, USA TEL: +1 (979) 865 8846 FAX: +1 (979) 865 8859 E-Mail: sales@seacon-ap.com Website: www.seacon-ap.com
Open the catalog to page 1molar`q==a^q^pebbq PRINCIPLE OF OPERATION The orccJkbh was designed to be an integral part of the MUX umbilical cable termination system shown below. The ^êãçê= qÉêãáå~íáçå= ^ëëÉãÄäó is secured to the riser or control system framework using a _êÉ~â~ï~ó= råáí that is designed to separate at a defined load. The smaller, more manageable orccJkbh is then routed and connected. In the case of accidental BOP droppage, the _êÉ~â~ï~ó=råáí shears, and the unarmored section of cable pulls out of the orccJkbh. ^q^=cfq^ Termination System Rochester A304862 Rochester 05605 Vector A71033** NSW 938600**...
Open the catalog to page 2All SEACON (Europe) catalogs and brochures
-
CS-MS Catalog Section - Rev IX
11 Pages
-
GRE
23 Pages
-
RUBBER-MOLDED_lres1
39 Pages
-
SAPL-DS-0110 MSSQ FCR Rev 3
2 Pages
-
SUTA
2 Pages
-
MSSQ RUFF-NEK
2 Pages
-
DS-0500
2 Pages
-
DS-0412
2 Pages
-
DS-0410
2 Pages
-
DS-0402
2 Pages
-
DS-0401
3 Pages
-
DS-0370
1 Pages
-
DS-0183
2 Pages
-
DS-0180
2 Pages
-
DS-0120
2 Pages
-
DS-0100
3 Pages
-
DS-0090
4 Pages
-
DS-0080
4 Pages
-
DS-0063
2 Pages
-
DS-0062
4 Pages
-
DS-0061
4 Pages
-
DS-0040
2 Pages
-
DS-0030
1 Pages
-
DS-0018
3 Pages
-
DS-0016
3 Pages
-
SEACON PRODUCTS 2015/16
8 Pages
-
SAPL-DS-0107 ATA Rev 4
2 Pages
-
SAPL-DS-0108 FITA Rev 3
2 Pages
-
SAPL-DS-0109 RA FCR Rev 2
2 Pages
-
SCE-DS-0002 PEEK 55 Rev 4
4 Pages
-
SCE-DS-0006 MSS Rev 2
6 Pages
-
SCE-DS-0009 VITON Rev 3
3 Pages
-
SAPL-DS-0020 Limit Switches
2 Pages
-
SAPL-DS-0121 Oil Filled Hose
2 Pages
-
SAPL-DS-0006 MICROSTAR
2 Pages
-
FIBER-OPTICS_Rev-VII_lres1
33 Pages
-
GLOBE-CON_Rev-II_lres1
8 Pages
-
MSS_Rev-VIII_lres1
21 Pages
-
U-MATE_Rev-I_lres1
11 Pages
-
ALL-WET_Rev-VII_lres1
29 Pages
-
SEA-MATE_Rev-III_lres2
20 Pages
-
SAPL-DS-0002-S-Series-S1-
2 Pages
-
SPECIALTY-PRODUCTS_lres
23 Pages
-
SWITCHES_lres1
14 Pages
-
FIELD-INSTALLABLE_lres1
20 Pages