DIVING WEAR DIVING WEAR MASKS, SNORKELS & FINS SLING GUNS PNEUMATIC GUNS KNIVES & LIGHTS
Open the catalog to page 2PASSION FAST FORWARD Today, Seac is certainly a company that sets benchmarks in the diving industry. Founded in 1971 as the brainchild of Marco Arata, more recently - thanks to the support of his son Daniele - the company is embarking on an important strategic renewal on several fronts: from the enrichment of the product lines to the expansion of the corporate organisation, from the repositioning of its image to the technological evolution in production. This impressive change has, however, left the true points of excellence that this company is known for unchanged; first of all, the inspection...
Open the catalog to page 3Today Seac presents itself on the international market as a customer-focused and streamlined brand representing strong business values. Internationalization of R&D department The essence of SEAC lies in its R&D department, which is located in Italy at the main office. A team of engineers and designers work in collaboration for the conception and realization of each final product with a strong Italian identity. Today SEAC is considered one of the best R&D operations in the sector - in facet, in recent years SEAC has brought it’s experience and expertise to other companies such as Arena. Production...
Open the catalog to page 4REGULATORS TECHNOLOGY During its 40th anniversary, Seac has decided to invest even more decisively, aiming directly at a regulator development project that began with the institution of a new cutting-edge department equipped with modern apparatus to collaborate during all phases of assembly, calibration, and inspection. This jewel in the Seac crown will consist of two ANSTI machines, the newest of which has been updated according to the latest EC EN250 standards, and can be used for dynamic testing both on dry land and in water. Seac regulators: reliability and performance, simplicity and sturdiness,...
Open the catalog to page 6Equipment Performance Ansti Certificate Reference Date : 7/11/2013 Equipment Regulator Type Serial Number Interstage Pressure Static Conditions of Test Room Temperature (C) Exhale Temp (C) Water Temp (C) HP Supply Pressure (barg) Tidal Volume (litre) Breath Rate (bpm) Ventilation Rate (lpm) Results (2 Loops) Inhale Pressure (mbar) Inhale Pos Pressure (mbar) Exhale Pressure (mbar) Ext Work of Breathing (J/l) Inhale Work (J/l) Pos Inhale Work (J/l) Exhale Work (J/l) Pressure - Volume Diagrams at Mean Depth of : 45.3 msw (148.7 fsw) Exhale RINA Certifications for Cold Water CE EN 250 2000 - V First...
Open the catalog to page 7Equipment Performance Ansti Certificate Reference Date : 7/10/2013 Equipment Regulator Type Serial Number Interstage Pressure Static I stadio DX 1000 I stadio DX 1000 0.00 barg Conditions of Test Room Temperature (C) Exhale Temp (C) Water Temp (C) HP Supply Pressure (barg) Tidal Volume (litre) Breath Rate (bpm) Ventilation Rate (lpm) Results (2 Loops) Inhale Pressure (mbar) Inhale Pos Pressure (mbar) Exhale Pressure (mbar) Ext Work of Breathing (J/l) Inhale Work (J/l) Pos Inhale Work (J/l) Exhale Work (J/l) Pressure - Volume Diagrams at Mean Depth of : 51.1 msw (167.7 fsw) Exhale RINA Certifications...
Open the catalog to page 8Equipment Performance Ansti Certificate Reference Date : 7/11/2013 Equipment Regulator Type Serial Number Interstage Pressure Static Conditions of Test Room Temperature (C) Exhale Temp (C) Water Temp (C) HP Supply Pressure (barg) Tidal Volume (litre) Breath Rate (bpm) Ventilation Rate (lpm) Results (2 Loops) Inhale Pressure (mbar) Inhale Pos Pressure (mbar) Exhale Pressure (mbar) Ext Work of Breathing (J/l) Inhale Work (J/l) Pos Inhale Work (J/l) Exhale Work (J/l) Pressure - Volume Diagrams at Mean Depth of : 50.4 msw (165.3 fsw) Exhale RINA Certifications for Cold Water CE EN 250 2000 IP - V...
Open the catalog to page 9Equipment Performance Ansti Certificate Reference Date : 7/12/2013 Equipment Regulator Type Serial Number Interstage Pressure Static Conditions of Test Room Temperature (C) Exhale Temp (C) Water Temp (C) HP Supply Pressure (barg) Tidal Volume (litre) Breath Rate (bpm) Ventilation Rate (lpm) Results (2 Loops) Inhale Pressure (mbar) Inhale Pos Pressure (mbar) Exhale Pressure (mbar) Ext Work of Breathing (J/l) Inhale Work (J/l) Pos Inhale Work (J/l) Exhale Work (J/l) Pressure - Volume Diagrams at Mean Depth of : 48.0 msw (157.5 fsw) Exhale RINA Certifications for Cold Water CE EN 250 2000 - V First...
Open the catalog to page 10Equipment Performance Ansti Certificate Reference Date : 7/11/2013 Equipment Regulator Type Serial Number Interstage Pressure Static Conditions of Test Room Temperature (C) Exhale Temp (C) Water Temp (C) HP Supply Pressure (barg) Tidal Volume (litre) Breath Rate (bpm) Ventilation Rate (lpm) Results (2 Loops) Inhale Pressure (mbar) Inhale Pos Pressure (mbar) Exhale Pressure (mbar) Ext Work of Breathing (J/l) Inhale Work (J/l) Pos Inhale Work (J/l) Exhale Work (J/l) Pressure - Volume Diagrams at Mean Depth of : 52.4 msw (171.9 fsw) Exhale RINA Certifications for Cold Water CE EN 250 2000 IP - V...
Open the catalog to page 11Equipment Performance Ansti Certificate Reference Date : 7/11/2013 Equipment Regulator Type Serial Number Interstage Pressure Static Conditions of Test Room Temperature (C) Exhale Temp (C) Water Temp (C) HP Supply Pressure (barg) Tidal Volume (litre) Breath Rate (bpm) Ventilation Rate (lpm) Results (2 Loops) Inhale Pressure (mbar) Inhale Pos Pressure (mbar) Exhale Pressure (mbar) Ext Work of Breathing (J/l) Inhale Work (J/l) Pos Inhale Work (J/l) Exhale Work (J/l) Pressure - Volume Diagrams at Mean Depth of : 52.9 msw (173.4 fsw) Exhale RINA Certifications for Cold Water CE EN 250 2000 IP - V...
Open the catalog to page 12RINA Certifications for Cold Water CE EN 250 2000 First stage materials: shiny chrome-plated brass • Second stage material: technopolymers, elastomers, and cover with Luxury Technology treatment for abrasion and scratch resistance • HP outlets: 2 • LP outlets: 5. NX 100 NITROX CODE WEIGHT (g) Nitrox 230 BAR 26X2 thread connector. Balanced membrane function with vertical set up. X100 OCTO NITROX CODE The side slots on the cover prevent free flow even under conditions of strong frontal currents (OWS System).
Open the catalog to page 13226 Pages
120 Pages
124 Pages
156 Pages
116 Pages
136 Pages
108 Pages
164 Pages
100 Pages
4 Pages
100 Pages
1 Page
1 Page
114 Pages
70 Pages
44 Pages
28 Pages
60 Pages
116 Pages
28 Pages
80 Pages
40 Pages
17 Pages
23 Pages
2 Pages
52 Pages
129 Pages
8 Pages