System Overview
  • Power Supply: Operates on 12/24 Volt DC, designed for marine use with vessel DC batteries. Optional standby rechargeable 24V battery backup available.
  • Modular Expansion: System can be expanded from 2 to 16 zones.
  • Fire Detection: Utilizes marine-approved heat and smoke detectors and manual call points for early warning.
  • Integration with Fire Extinguisher: Fully integrates with Sea-Fire extinguishers for low pressure and discharge alarms.
  • Machinery Shutdown Management: Integrated relays for shutting down engines, generators, and ventilation upon fire extinguisher discharge.
  • User Interface: Multiple display panels can be located throughout the vessel, designed to complement modern yacht aesthetics.
Control Unit (131-500)
  • Microprocessor-based, central to the system, with 7 relays for machinery shutdown.
  • Powered by two independent battery banks, each monitored for failure.
  • Monitors Sea-Fire extinguisher discharge and low pressure, triggering machinery shutdown.
  • Monitors all primary inputs for open and short circuits.
Technical Specifications
  • Mechanical: Dimensions 255x180x61 mm, weight 1kg, ABS plastic enclosure.
  • Electrical: Supply voltage 15-28 Vdc, recommended fuse 5 amp, multiple inputs and outputs for alarms and machinery shutdown.
Adapter Unit (131-520)
  • Expands detection zones by 4 per unit, up to 16 zones total.
  • Connects via RJ45 sockets to Zone Identification Panel.
Zone Identification Panel (131-529)
  • Provides system status with LED indicators and internal buzzer for alarms.
  • Customizable zone legends, connects via CAT5 cable.
Display Panel (131-510)
  • Weatherproof, provides status indication and system control, connects via CAT5 cable.
  • Supports multiple displays throughout the vessel.
Hochiki Detectors
  • Compatible with Hochiki CDX conventional detectors, marine approved.
  • Includes photoelectric smoke detector and combined heat detector.
Ancillary Equipment
  • Interface unit available for connecting normally closed equipment to detection zones.
Operation Overview
  • Fire Detection: Uses Hochiki detectors, expandable from 2 to 16 zones, with LED and alarm indicators.
  • Machinery Shutdown: Initiated by control unit upon extinguisher discharge, restartable via reset button.
  • Fire Extinguisher Monitoring: Monitors discharge and low pressure states, with fault monitoring.
  • Fault Monitoring: Detection zones monitored for open and short circuit faults.
  • Display Panels: Provide system control and status, multiple installations possible.
Ordering Information
  • Includes part numbers for control unit, display panel, adapter unit, zone identification panel, interface unit, detectors, and accessories.
Compliance
  • Assessed for immunity and emissions to EN 60945: 2002 standards.
Contact Information
  • Sea-Fire Marine, Baltimore, MD, USA and Sea-Fire Europe Ltd, Portsmouth, UK.
See more

Catalog excerpts

Non-USCG-1

INTEGRATED MARINE Fire CONTROL PANEL FIRE DETECTION FIRE EXTINGUISHER SUPERVISION ENGINE AND MACHINERY SHUTDOWN

 Open the catalog to page 1
Non-USCG-2

System Overview • 12/24 VOLT DC esigned specifically as a marine D integrated fire system to work with vessels DC batteries. tandby re-chargeable 24v battery back S up available as an option. • MODULAR EXPANSION esigned as a modular system, that can D be expanded from 2 to 16 zones. • EARLY WARNING FIRE DETECTION arine approved Heat and Smoke M detectors and Manual Call Points. Supervisory PRESSURE SWITCH • NTEGRATION WITH FIRE I EXTINGUISHER ully integrates with Sea-Fire preF engineered and ‘H’ Series extinguishers to provide low pressure and discharge alarms. • ACHINERY SHUTDOWN M MANAGEMENT...

 Open the catalog to page 2
Non-USCG-4

131-500 - Control Unit The microprocessor Control Unit is the heart of the integrated system. 7 relays (rated at 16 amps each) provide for machinery shutdown when the Control Unit detects that the Sea-Fire extinguisher has discharged. For security, the Control Unit is powered from two independent battery banks. Each power input is monitored for failure. There are two inputs for monitoring the Sea-Fire extinguisher. When used in conjunction with an ‘H’ series extinguisher, the unit can monitor Discharge as well as Low Pressure. A discharge event will trigger the machinery shutdown. All primary...

 Open the catalog to page 4
Non-USCG-5

131-529 - Zone Identification Panel The Zone Identification Panel (ZIP) provides the user with system status and has two tactile buttons for system control. In the event of an alarm, a Zone LED will light and the internal buzzer will sound. The ZIP is customisable to be able to accommodate user defined Zone legends. The ZIP’s are connected to the Adapter panels and the Control Panel via CAT5 cable. Two ZIP’s can be fitted to each system. TECHNICAL SPECIFICATION Mechanical: Dimensions (mm): 205(W) x 135(H) x 3(D) Weight: 183g Material: F4 PCB and Polyester overlay Electrical: Connects to Adapter...

 Open the catalog to page 5
Non-USCG-6

Hochiki Detectors The FCP has been designed to operate with the Hochiki range of CDX conventional detectors. This range of detectors have been Marine approved by GL and LR. The primary detectors are a Photoelectric smoke detector and a combined ROR and fixed 90 deg heat detector. These detectors have been chosen for their accuracy and reliability and also because of aesthetic considerations. Anciliary Equipment An Interface unit (Part No. 131-499) can be used to connect any Normally Closed equipment to on of the detection zones. For example, the FCP can be used to monitor bilge alarms, Carbon...

 Open the catalog to page 6
Non-USCG-7

Operation Overview Ordering Information Fire Detection: Control Unit The FireStop FCP uses the Marine Approved Hochiki range of CDX conventional detectors. The FCP can be expanded to detect fire from 2 to 16 zones. Each zone can support two detectors. Display Panel Adapter Unit Zone Identification Panel Interface Unit In the event of a fire, the fire location will be identified on the Zone Identification Panel via a lit LED and an alarm sounding. Multiple displays can be used throughout the vessel. D CD-CE3/M Heat Detector 90C fixed rate of rise D CD-AE3/M Heat Detector 60C fixed rate of rise...

 Open the catalog to page 7
Non-USCG-8

Distributed worldwide by Sea-Fire Marine 9331-A Philadelphia Road Baltimore MD21237 USA Unit 2 Discovery Voyager Park Portfield Road, Portsmouth Hampshire PO3 5FN, UK Manufactured in the UK by Blue Marble Solutions Ltd.

 Open the catalog to page 8

All Sea-Fire Europe Ltd catalogs and brochures

  1. USCG

    2  Pages

Archived catalogs

  1. FT SERIES

    2  Pages

  2. C-SERIES

    2  Pages

  3. FD-FG SERIES

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.