Technical lighting since 1927 Luminaire for circulation area light
Open the catalog to page 1TURNER 70 OUTDOOR lighting THE LIGHTING SOLUTION FOR CIRCULATION AREA LIGHTING Lighting spaces with outdoor traffic flows (around housing, railway platforms, etc.) demands the use of luminaires that meet specific constraints associated with the presence of the public, the needs of lighting performance and energy efficiency, as well as responding to the need for aesthetic integration. Such urban environments are demanding - lighting must withstand pollution, impacts and UV-related ageing without requiring much maintenance. The TURNER 70 range of luminaires has been designed specifically for...
Open the catalog to page 2Our luminaires have robust envelopes that are required in industrial environments, protecting them from the ordeals of the urban environment: they are pollution-resistant, can tolerate intensive use, are robust, and have durable sealing, etc. NO YELLOWING OF THE DIFFUSER The TURNER 70 range has composite anti-yellowing diffusers that protect them from solar UV radiation. With a polycarbonate body, they are protected by a co-extruded methacrylate layer which acts as a protective barrier against solar UV radiation. INNOVATIVE DESIGN FOR EASE OF MAINTENANCE By separating installation and...
Open the catalog to page 3TURNER 70 OUTDOOR lighting CASE STUDY: EXTERNAL WALKWAY TURNER 70’s intrinsic qualities make it a luminaire ideally suited for lighting outside walkways. It achieves an average illuminance of 100 lux at floor level, recommanded in the construction of residential buildings providing access for those with disabilities. Luminaires used: TUR70 15M830 POME 113 SA Installation height: 2.5 m Results: Total consumption = 186 W Calculated average illuminance: 103 lux Uniformity: 0.59
Open the catalog to page 4CASE STUDY: STATION PLATFORM The TURNER 70 was designed to optimise lighting installations for railway platforms. Suitable for awnings, it creates an average illuminance of 100 lux at floor level, required by EN 12464-2, and with minimum consumption. Luminaires used: TUR70 15M830 POME 113 SA Installation height: 3.7 m Results: Total consumption = 740 W Calculated average illuminance: 106 lux Uniformity: 0.5 To optimize your installation, contact Sammode or our local representative
Open the catalog to page 5TURNER 70 IMPERVIOUS TUBULAR LUMINAIRE FOR OUTDOOR TRAFFIC FLOWS DESCRIPTION HOUSING LED TECHNOLOGY Instantaneous full light output on ignition over the entire temperature range of use Designed for repeated switching on and off IMPERVIOUS (IP68/IP69K) Fully sealed No internal accumulation of dust Maximum light output Designed for pressure cleaning EASY INSTALLATION AND MAINTENANCE Patented automatic electrical connection on closure (Close’n Connect) Maintenance by removal of the end cap at the end opposite the cable entry Easily maintainable LED modules and electronic equipment COMPACT SIZE...
Open the catalog to page 6Variable centre distance MAIN REFERENCE! CABLE ENTRIES Disconnectable plugs P68/IP69K plug with locking threaded ring in aluminium 5 pole (with dimmable ballast] Disconnectable cable (0.80 m long] Output via a cable fitted with a WIELAND IP68 plug GEAR UNITS Electronic ballast for DALI dimming Electronic ballast for push-button dimming OPTION CODE DESCRIPTION OPTION CODE End caps and fixing straps in 316L stainless steel MR nternal colour gelatine LFXXX Fixing straps with HSHC screw BAV Fixing straps with tamper-resistant Torx screw BAVT Cable plate in stainless steel 0 80 mm with cable...
Open the catalog to page 7Sammode 24 rue des Amandiers, 75020 Paris, France T +33 (0)1 43 14 84 90 F +33 (0)1 47 00 59 29 www.sammode.com Photos : Rodrigo Rojas • We reserve the right to make technical changes • © Sammode - 11/2013 – european area version
Open the catalog to page 8All Sammode catalogs and brochures
-
Emergency Lighting
12 Pages
-
Indoor lighting
146 Pages
-
Outdoor lighting
103 Pages
-
Brochure ATEX EN
16 Pages
-
General Lighting Industry
127 Pages
-
BROCHURE ATEX SAMMODE
20 Pages
-
MONDRIAN
8 Pages
-
Lighting in ATEX zones LED
32 Pages
-
Boyle 100 Task lighting
8 Pages
-
Hutton 100 Task lighting
8 Pages
-
Hutton 133
8 Pages
-
Hutton 100
8 Pages
-
Jamin 133
8 Pages
-
Jamin 100
8 Pages
-
Jamin 100 Task lighting
8 Pages
-
Boyle 133
8 Pages
-
Boyle 100
8 Pages
-
Amenity lighting
16 Pages
-
VOUET 100
8 Pages
-
Celsius 70 SA 613mm
8 Pages
-
Celsius 70 SA 1613mm
8 Pages
-
Celsius 70 W
8 Pages
-
Bering 133
8 Pages
-
Bering 100 (Task lighting)
8 Pages
-
Bering 100
8 Pages
-
Amundsen 133
8 Pages
-
Amundsen 100 (Task lighting)
8 Pages
-
Amundsen 100
8 Pages
-
DIRAC
2 Pages
-
Davy 133
2 Pages
-
Davy 100
2 Pages
-
Lorentz
1 Pages
-
Newton 450 FC
1 Pages
-
Hudson
8 Pages
-
Brochure Machine Lighting
16 Pages
-
Newton 450 SHP
1 Pages
-
Newton 450 DLM
2 Pages
-
Pauli 1 HT80
2 Pages
-
Pauli1 HT100
2 Pages
-
Pauli 1 HT200
1 Pages
-
Pauli 2 GF
2 Pages
-
Pauli 2 TGF
2 Pages
-
MAXWELL LSC AMB
4 Pages
-
MAXWELL LSC EVAC
4 Pages
-
MAXWELL S3H
4 Pages
-
MAXWELL S1H
4 Pages
-
MAXWELL LSC BT
4 Pages
-
CRANACH 70
8 Pages
-
SEURAT 40
8 Pages
-
Brochure 5 year warranty
4 Pages
-
PAULI 1 HT 80
2 Pages
-
EINSTEIN 133 CL2
2 Pages
-
EINSTEIN 100 CL2
2 Pages
-
KELVIN 100
2 Pages
-
KELVIN 100 FC
2 Pages
-
KELVIN 133
2 Pages
-
PASCAL
8 Pages
-
Ships
2 Pages
-
Ports
2 Pages
-
HOPKINS-SECOURU
2 Pages
-
HUYGENS
2 Pages
-
PAULI-1-HT80
2 Pages
-
Brochure Industry - Sammode
16 Pages
Archived catalogs
-
SAMMODE - EMERGENCY LIGHTING
20 Pages
-
NIEPCE-70-T8-FERRO
2 Pages
-
EINSTEIN-133
2 Pages
-
EINSTEIN-100
2 Pages