Catalog excerpts
explosive environments Lighting 140311-SZ - doc ATEX sans pages prod_FR, DE, EN.indd 1
Open the catalog to page 1The zones where explosive atmospheres may be formed are defined T3 200°C CLASSIFICATION OF THE ZONES by the operator: T4 TEMPERATURE CLASSES T5 GAS AND VAPOURS DUST T6 TEMPERATURE CLASS 135°C 100°C PRESENCE OF 85°C MAXIMUM SURFACE EXPLOSIVE ATMOSPHERE TEMPERATURE ZONE 0 ZONE 20 T2 300°C Category 1G Category 1D Permanent PROTECTION METHODS T3 200°C ZONE 1 ZONE 21 In of are used T4GAS zones, three main types2D protectionOccasional the design of 135°C for Category 2G Category T5 for explosive atmospheres: 100°C lights 2 ZONE ZONE 22 T6 85°C Category 3G Category 3D Accidental Increased safety...
Open the catalog to page 2KEPLER LAMARCK GENERAL LIGHTING Normal environments Harsh environments DAVY HOPKINS Sammode, recognised provider of specialised lighting for ATEX environments, is FLOODLIGHT expanding its range by offering more robust and durable solutions. In addition to HUYGENS SILO x x providing lighting satisfying our clients’ increasingly complex requirements and SELF-CONTAINED conditions of use, we will introduce you to our range of general lighting for normal x x x x and harsh environments, as HOPKINS SC floodlights and self-contained luminaires. well as our PRODUCT GUIDE KEPLER LAMARCK DAVY HOPKINS...
Open the catalog to page 3ZONES 2, 21 AND 22 - EASY MAINTENANCE - 1 T8 LAMP KEPLER 100 EASY MAINTENANCE IMPERVIOUS TUBULAR LIGHT FITTING FOR EXPLOSIVE ENVIRONMENTS TUBULAR HOUSING • Ø100 mm coextruded polycarbonate/PMMA diffuser for outdoor lighting and chemically aggressive environments Increased mechanical resistance Easy to clean Limited dirt accumulation 360° orientation • End caps 1/2 ring press-formed in 304L stainless steel (316L also available) • Gaskets moulded in EPDM • Cable entry with cable gland • Possibility for a model with 2 cable entries for looping-in (2 cable glands with stopper plug or 1...
Open the catalog to page 4IN REFERENCES - ELECTRONIC BALLAST VERSION Version without reflector Version with intensive reflector Version with extensive reflector MAIN REFERENCES - INDUSTRIAL ELECTRONIC BALLAST VERSION Version without reflector Version with intensive reflector Version with extensive reflector OPTION CODE DESCRIPTION OPTION CODE CABLE ENTRIES 1 or 2 cable glands in black polyamide 1 cable gland in black polyamide and 1 blind plug (Hole 0:20 mm) 1 or 2 cable glands in nickel-coated brass GEAR UNIT 5-point terminal block for phase balancing C5P End caps and fixing straps in 316L stainless steel MR...
Open the catalog to page 5ZONES 2, 21 AND 22 - EASY MAINTENANCE - 2 T8 LAMPS KEPLER 133 EASY MAINTENANCE IMPERVIOUS TUBULAR LIGHT FITTING FOR EXPLOSIVE ENVIRONMENTS TUBULAR DESCRIPTION HOUSING • Ø133 mm coextruded polycarbonate/PMMA diffuser for outdoor lighting and chemically aggressive environments Increased mechanical resistance Easy to clean Limited dirt accumulation 360° orientation • End caps 1/2 ring press-formed in 304L stainless steel (316L also available) • Gaskets moulded in EPDM • Cable entry with cable gland • Possibility for a model with 2 cable entries for looping-in (2 cable glands with stopper plug...
Open the catalog to page 6Version without reflector Version with intensive reflector MAIN REFERENCES - INDUSTRIAL ELECTRONIC BALLAST VERSION Version without reflector Version with intensive reflector OPTION CODE DESCRIPTION OPTION CODE CABLE ENTRIES 1 or 2 cable glands in black polyamide 1 cable gland in black polyamide and 1 blind plug (Hole 0:20 mm) 1 or 2 cable glands in nickel-coated brass GEAR UNIT 5-point terminal block for phase balancing C5P End caps and fixing straps in 316L stainless steel MR Reinforced bolt-fitted fixing straps BRS Fixing straps with HSHC screw* BAV Reinforced bolt-fitted fixing straps...
Open the catalog to page 7ZONES 1,2, 21 AND 22 - EASY MAINTENANCE - 1 OR 2 T8 LAMPS EASY MAINTENANCE IMPERVIOUS TUBULAR LIGHT Increased mechanical resistance Limited dirt accumulation Absolute imperviousness No internal dust accumulation Maximum light output Adapted for pressure cleaning EASY MAINTENANCE Easy opening and closing with just one screw Relamping without need to remove the gear High resistance to corrosion and external Robustness of the housing, quality of the long-term investment ELECTRICAL CLASS FIRE RESISTANCE SHOCK RESISTANCE OPERATING TEMPERATURE diffuser for outdoor lighting and chemically...
Open the catalog to page 8Variable centre distance Version without reflector Version with intensive reflector Version with extensive reflector MAIN REFERENCES - 2-LAMP MODI Version without reflector Version with extensive reflector OPTION CODE DESCRIPTION OPTION CODE CABLE ENTRIES 1 or 2 cable glands in black polyamide 1 cable gland in black polyamide and 1 blind plug (0 20mm) 1 or 2 cable glands in nickel-coated brass Level reflector [1-lamp versions) RN GEAR UNIT 5-point terminal block for phase balancing C5P End caps and fixing straps in 316L stainless steel MR Fixing straps with HSHC screw* BAV Reinforced...
Open the catalog to page 9ZONES 2, 21 AND 22 - REINFORCED RESISTANCE– BOROSILICATE GLASS – 1 LAMP T8 DAVY 100 IMPERVIOUS LIGHT FITTING FOR DIFFICULT EXPLOSIVE ENVIRONMENTS TUBULAR Increased mechanical resistance Easy to clean Limited dirt accumulation 360° orientation HOUSING • Ø100 mm diffuser in borosilicate glass for corrosive environments • Also available in coextruded polycarbonate/PMMA for chemically aggressive environments and outdoor lighting • End caps 1/2 ring press-formed in 304L stainless steel (316L also available) • Gaskets moulded in EPDM • Cable entry with cable gland • Possibility for a model with 2...
Open the catalog to page 10MAIN REFERENCES-ELECTRONIC BALLAST VERSION Version without reflector Version with intensive reflector Version with extensive reflector MAIN REFERENCES - INDUSTRIAL ELECTRONIC BALLAST VERSIOI Version without reflector Version with intensive reflector Version with extensive reflector OPTION CODE DESCRIPTION OPTION CODE CABLE ENTRIES 1 or 2 cable glands in black polyamide 1 cable gland in black polyamide and 1 blind plug 1 or 2 cable glands in nickel-coated brass GEAR UNIT 5-point terminal block for phase balancing Coex. polycarbonate/PMMAdiffuser POME End caps and fixing straps in 316L...
Open the catalog to page 11All Sammode catalogs and brochures
-
Emergency Lighting
12 Pages
-
Indoor lighting
146 Pages
-
Outdoor lighting
103 Pages
-
Brochure ATEX EN
16 Pages
-
General Lighting Industry
127 Pages
-
MONDRIAN
8 Pages
-
Lighting in ATEX zones LED
32 Pages
-
Boyle 100 Task lighting
8 Pages
-
Hutton 100 Task lighting
8 Pages
-
Hutton 133
8 Pages
-
Hutton 100
8 Pages
-
Jamin 133
8 Pages
-
Jamin 100
8 Pages
-
Jamin 100 Task lighting
8 Pages
-
Boyle 133
8 Pages
-
Boyle 100
8 Pages
-
Amenity lighting
16 Pages
-
VOUET 100
8 Pages
-
Celsius 70 SA 613mm
8 Pages
-
Celsius 70 SA 1613mm
8 Pages
-
Celsius 70 W
8 Pages
-
Bering 133
8 Pages
-
Bering 100 (Task lighting)
8 Pages
-
Bering 100
8 Pages
-
Amundsen 133
8 Pages
-
Amundsen 100 (Task lighting)
8 Pages
-
Amundsen 100
8 Pages
-
DIRAC
2 Pages
-
Davy 133
2 Pages
-
Davy 100
2 Pages
-
Lorentz
1 Pages
-
Newton 450 FC
1 Pages
-
Hudson
8 Pages
-
Brochure Machine Lighting
16 Pages
-
Newton 450 SHP
1 Pages
-
Newton 450 DLM
2 Pages
-
Pauli 1 HT80
2 Pages
-
Pauli1 HT100
2 Pages
-
Pauli 1 HT200
1 Pages
-
Pauli 2 GF
2 Pages
-
Pauli 2 TGF
2 Pages
-
MAXWELL LSC AMB
4 Pages
-
MAXWELL LSC EVAC
4 Pages
-
MAXWELL S3H
4 Pages
-
MAXWELL S1H
4 Pages
-
MAXWELL LSC BT
4 Pages
-
CRANACH 70
8 Pages
-
SEURAT 40
8 Pages
-
Brochure 5 year warranty
4 Pages
-
PAULI 1 HT 80
2 Pages
-
EINSTEIN 133 CL2
2 Pages
-
EINSTEIN 100 CL2
2 Pages
-
KELVIN 100
2 Pages
-
KELVIN 100 FC
2 Pages
-
KELVIN 133
2 Pages
-
TURNER 70
8 Pages
-
PASCAL
8 Pages
-
Ships
2 Pages
-
Ports
2 Pages
-
HOPKINS-SECOURU
2 Pages
-
HUYGENS
2 Pages
-
PAULI-1-HT80
2 Pages
-
Brochure Industry - Sammode
16 Pages
Archived catalogs
-
SAMMODE - EMERGENCY LIGHTING
20 Pages
-
NIEPCE-70-T8-FERRO
2 Pages
-
EINSTEIN-133
2 Pages
-
EINSTEIN-100
2 Pages