| Model | A (mm) | B (mm) | C (mm) | D (mm) | E (mm) | F (mm) | G (mm) | H (mm) | I (mm) | K (mm) | Weight (kg) |
|---|---|---|---|---|---|---|---|---|---|---|---|
| GCU 300 | 6,100 | 2,900 | 2,600 | 5,230 | 800 | 1,650 | 1,200 | 2,200 | 2,600 | 1,300 | 36,000 |
| GCU 450 | 6,900 | 4,880 | 3,620 | 5,310 | 1,530 | 2,800 | 1,800 | 3,150 | 4,000 | 1,400 | 40,000 |
| GCU 550 | 7,400 | 5,400 | 4,010 | 6,310 | 1,790 | 2,800 | 1,800 | 3,800 | 5,000 | 1,500 | 46,000 |
| GCU 650 | 7,850 | 5,900 | 4,410 | 6,580 | 2,000 | 3,100 | 1,800 | 3,800 | 5,000 | 1,500 | 50,000 |
| Model | Boil-off-Gas (t/h) | P (MW) | Flue Gas Temperature (°C) | Flue Gas Flow (m3N/s) |
|---|---|---|---|---|
| GCU 300 | 3.0 | 41.5 | 450 | 77.75 |
| GCU 450 | 4.5 | 62.3 | 450 | 116.61 |
| GCU 550 | 5.5 | 76.1 | 450 | 142.53 |
| GCU 650 | 6.5 | 89.9 | 450 | 168.44 |
Gas Combustion Unit - GCU-Series Gas Combustion Unit - GCU-Series Technical data: GCU Capacity 0.15-6.5 t/h methane With its special design, the GCU combines all advantages of economic, operationally reliable and environmentally friendly combustion on sea. ^1 Rain-proof design to avoid corrosion and wearing of the GCU components, especially the burner and the combustion chamber bottom ^1 The inner lining in the combustion chamber provides a cold and therefore strong structure of the GCU ^1 High air excess provides low flame temperature for low heat radiation and low NOX emissions ^1 No flame touching of the combustion chamber wall if the ship is rolling in heavy sea and therefore no wearing or damaging of the combustion chamber ^1 No belt driven fans for low maintenance cost ^1 Oil pilot burner for unlimited continuous operation if required during special circumstances ^1 Controlled fuel air ratio for safe combustion and low emissions ^1 For maintenance it is possible to remove or replace inner parts like combustion chamber and burner via funnel ^1 Gap between combustion chamber and outer shell is accessible ^1 100 % free flow possible ^1 All gases are completely burned
Open the catalog to page 1Front view Burner dimensions* and weightModel ABCDEFGHIK Burnerweight** mm mm mm mm mm mm mm mm mm mm kg (ca,) * details and other sizes on demand ** including insulation SAACKE GmbH SudweststraBe 13 28237 Bremen, Germany [email protected] www.saacke.com
Open the catalog to page 22 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
32 Pages