| Steam Capacity (t/h) | Design Pressure (MPa) | Main Engine | A* (mm) | B** (mm) | Boiler Dry Weight*** (kg) | Water Volume at NWL (m3) |
|---|---|---|---|---|---|---|
| 1.7 | 1.0 | MAN B&W 12V 46/60 at 100% MCR ISO condition | 4500 | 2350 | 10000 | 5.0 |
| 2.0 | 1.0 | MAN B&W 18V 48/60 at 100% MCR ISO condition | 4800 | 2450 | 16000 | 5.5 |
| 3.5 | 1.0 | MAN B&W 8K 98 MC-C at 90% MCR ISO condition | 6300 | 3350 | 30000 | 15.0 |
| 4.5 | 1.0 | MAN B&W 8K 98 MC-C at 90% MCR ISO condition | 6900 | 3650 | 36500 | 21.0 |
Exhaust Gas Marine Boiler Exhaust Gas Marine Economiser Design Features The EMB/EME-VST is a vertical smoke tube exhaust gas boiler resp. économiser that also fulfils partly the function of a silencer in the exhaust gas system. The heat transfer is performed through plain smoke tubes that are easy to clean and maintain. The exhaust gas boiler EMB-VST has its own steam space and therefore it works independently from other boilers in the system. The exhaust gas économiser EME-VST has to be connected to a fired boiler or a separate steam drum by means of forced circulation. The EMB/EME-VST is suitable for dry running in emergency case. MARINE SYSTEMS heat generating plants
Open the catalog to page 1* including insulation ** including insulation and valves y-f;T.\H A =f MARINE SYSTEMS SAACKE GmbH ■ Siidweststrasse 13 ■ 28237 Bremen ■ Germany ■ Phone: +49 - 421 - 64 95 0 ■ eMail: [email protected]