Design Features
The SAACKE steam atomising burner is engineered for medium to large water tube boilers, suitable for auxiliary and main boilers on tankers and FPSOs. It features a unique staged combustion air supply and distribution, allowing a high turn down ratio and ensuring complete combustion with low O2 values, even at low loads. The burner maintains a stable flame across the entire load range and is adaptable for both side and top-fired boilers. Fuel-air ratio management is achieved through an electronic compound regulator paired with a PLC combustion controller, with an option for a mechanical regulator.

Applications
This burner is available as a combined oil and gas burner (type DDZG) for FPSOs and LNG carriers.

Specifications
  • Capacity: 8.5 – 37 MW
  • Fuel Types: Heavy Fuel Oil (up to 700 cSt/50 °C), Marine Diesel Oil, Marine Gas Oil, and Natural Gas
  • Turn Down Ratio: 1:7 for burners up to 13.5 MW, 1:10 for 13.5 – 21 MW, 1:15 for > 21 MW

Technical Data
The document provides detailed dimensions and capacities for various burner models (DDZ M 100 to DDZ M 450), including outlet part diameter, maximum capacity, boiler output, and specific measurements for installation. The data is specific to boiler types FMB-VM and FMB-VL with air temperature at 45°C.

Contact Information
SAACKE GmbH, Südweststrasse 13, 28237 Bremen, Germany. Phone: +49 - 421 - 64 95 0. Email: [email protected]. Website: www.saacke-marine-systems.com
See more

Catalog excerpts

03_PB_DDZ-M-1

Steam Atomising Burner Turn down ratio Natural gas standard and all others on demand, e.g. natural gas from well Design Features The SAACKE steam atomising burner is designed for firing medium and large sized water tube boilers such as auxiliary and main boilers for The unique SAACKE-design features staged combustion air supply and distribution. This allows a high turn down ratio and ensures complete J combustion, resulting in low 02 values even when operating on low load At the same time, a very stable flame over the whole load range is given. On account of its highly versatile flame geometry, the DDZ burner is equally suitable for side fired and top fired boilers. The fuel-air ratio is controlled by an electronic compound regulator in combination with a PLC combustion controller. A mechanical compound regulator can be supplied on demand. For FPSOs and LNG carrier applications this burner is available as a combined oil and gas burner, of type DDZG. t^fiTiTH A MARINE SYSTEMS heat generating plants

 Open the catalog to page 1
03_PB_DDZ-M-2

"only for boiler FMB-VM and FMB-VL and air temperature 45°C ** minimal length *** depends on actual burner design [^f;T;TH:H MARINE SYSTEMS SAACKE GmbH ■ Siidweststrasse 13 ■ 28237 Bremen ■ Germany ■ Phone: +49 - 421 - 64 95 0 ■ eMail: [email protected]

 Open the catalog to page 2

All SAACKE catalogs and brochures

  1. se@vis pro

    2  Pages

  2. se@vis eco

    2  Pages

  3. Coke Oven Gas

    2  Pages

  4. LONOX UCC

    2  Pages

  5. EGCS-HM

    2  Pages

  6. Spare parts

    2  Pages

  7. Boiler Repair

    2  Pages

  8. 05_PB_SKV-A

    2  Pages

  9. FMB-VF-Lonox

    2  Pages

  10. 14_PB_FMB-VD

    2  Pages

  11. 19_PB_EME-VFT

    2  Pages

  12. 08_PB_CMB-VS

    2  Pages

Archived catalogs

  1. 09_PB_CMB-HF

    2  Pages

  2. 20_PB_FMW-VD

    2  Pages

  3. System_Progress

    32  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.