DAT 09g
4Pages

{{requestButtons}}

Catalog excerpts

DAT 09g - 1

VentSafe: Cargo Tank Pressure Monitoring and Alarm System • Detects over or under (vacuum) pressure conditions in a cargo tank and triggers an alarm to prevent deformation in case of primary pressure release valve failure Complies with SOLAS 11-2/59.1 regulations by providing an alternative to the secondary venting of cargo • Also complies with subsequent Meets the ExxonMobil MESQAC guide for affiliate vessel vetting as well as OCIMF and SIRE best practices • Cost effective to install in new builds or as a retrofit to existing ships • Simple to operate and reliable based on marine approved components Part of the ComplianceSystems product group PSM Instrumentation Ltd, Unit3 Burrell Road, Haywards Heath, West Sussex, RH16 1TW. UK Subject to change without notice

Open the catalog to page 1
DAT 09g - 2

Cargo Tank Pressure Monitoring and Alarm System SOLAS II-2/59.1 regulation effective July 1998, and subsequent SOLAS II-2/4.5.3.2.2, II-2/11.6.3.2 and IACS UI SC 140 regulations effective July 2013, requires that a secondary means of allowing full flow of vapour, air or inert gas is provided in the event that the primary pressure relief valve arrangement fails. This ensures that the cargo tank is operated within its design limits and is not mechanically damaged by over or under (vacuum) pressure. Alternatively, and more cost effectively (especially where retrofit is required), the...

Open the catalog to page 2
DAT 09g - 3

MTU Central Monitor, Control and Alarm Panel The MTU is a powerful yet simple to use central monitoring, control and alarm unit. Designed, constructed and approved for marine applications such as inert gas tank blanket pressure measurement Comprising a 7” IP65 HMI unit panel mounted into an optional epoxy coated steel enclosure it is suitable for marine applications and installations. The MTU is supplied pre-configured according each installation with the tank details and descriptions, as well as the four alarm setpoints required by the regulations. Input is a Modbus loop is used for...

Open the catalog to page 3
DAT 09g - 4

Typical system components MTU Central Monitor, Control and Alarm Panel mounted in cargo control room Optional relay outputs for remote mounted audible and visual alarms RFM-ISR zener barrier module Required for hazardous area installation Ict 1000 pressure transmitters Mounted on top of tank or vent pipe Ship’s tanks or gas vent pipes © PSM INSTRUMENTATION LTD Data Sheet Ref: DAT 09g 28/02/2013 PSM Instrumentation Ltd, Unit 3 Burrell Road, Haywards Heath, West Sussex, RH16 1TW. UK Subject to change without notice

Open the catalog to page 4