Power Generation - 1

aerospace climate control electromechanical filtration fluid &gas handling hydraulics pneumatics process control sealing & shielding Power Generation Filtration Solutions Parker Racor ENGINEERING SUCCESS.

Open the catalog to page 1
Power Generation - 2

400 Series Quality In One Easy Spin • High capacity, on-engine, primary or secondary filtration • Fits most existing mounting heads • See-thru bowl with water sensor option • Includes a palm-operated primimg pump AquablocTI media sheds water and keeps engines waterproof, rustproof, and dirtproof. A durable mounting bracket doubles resistance to vibration fatigue. Polymer bowl withstands impact and temperature extremes. Fuel Dispensing Racor's new FBO-IO and FBO-14 filter asemblies are designed to meet the toughest hydrocarbon refueling conditions and provide for ease of filter...

Open the catalog to page 2
Power Generation - 3

700 Series Integrated Filter/Separator 700 Series filters are equipped with state-of-the-art fuel pumps with either brush or brushless DC motors. In brushless versions, the motor shaft directly drives the gerotor, creating a unique, positive displacement pump. The gerotor has fewer parts than gear or vane pumps, and the sensorless control technology of the brushless DC motor makes this product the most reliable filter and pump assembly on the market. The brushless pump assembly is ideal for tough on-engine applications. For off-engine mounting, brushed pumps are a more economical...

Open the catalog to page 3
Power Generation - 4

LFS RK46267—The New Generation Of Top-Load Filters LFS RK761 OilChek™ Portable Oil Monitor The oil monitor measures the effect of all the contaminants and the electro chemicals that occur in synthetic and petroleum based oils. This is acheived by detecting and measuring the oil's dielectric constant. Use with engine oil, transmission fluid, or hydraulic fluid. Racor Top-Load Lubrication Filters include a high effeciency, environmentally clean, cartridge replacement filter with a safety bypass valve, auto drain-back to the sump for service, and an anti drain-back valve to prevent dry...

Open the catalog to page 4
Power Generation - 5

Now, engine owners have the opportunity to combine the Racor Full-Flow Lubrication Filtration System with a highly efficient, environmentally safe Bypass Oil Filtration System. Never Lo Oil Replenishing Systems Never Lo Oil Replenishing Systems, automatic or manual, provide a constant supply of fresh, clean oil to the engine. • The AFG Automatic Gravity System continuously monitors engine oil and automatically maintains it at a pre-adjusted level. The system requires no electrical connections and is easy to install. • The Push-Button Manual Pressurized Remote Fill Oil Replenishing System...

Open the catalog to page 5
Power Generation - 6

The Pamic® Series Pamic filters have an average efficiency rating of 99.9% and it increases throughout the life of the filter. The unique construction of the Pamic filter with its exclusive mechanical pleat separation provides more usable filter area than any competitive air cleaner, thus offering longer filter life. UniPamic models feature an efficient moisture separator panel which removes over 90% of the water that may enter the face of the air cleaner. AutoPamic® models can be upgraded to include a gravity-discharged dust precleaner. RotoPamic® models are upgradeable to either...

Open the catalog to page 6
Power Generation - 7

Racor engineers have not only revolutionized the performance of air filtration, but also how the unit is installed and serviced. It's a mounting system invented for flexibility and convenience. The reversible base mounting bracket and included hardware mounts quickly, in any direction to frame rail or firewall. This complete mounting system eliminates the need for custom made, field-engineered, and installed brackets—a significant savings of time and money. A key feature of the ECO III is the tangential orientation of the 7" inlet, which directs air flow evenly around the filter. By...

Open the catalog to page 7
Power Generation - 8

In an open system, the crankcase breather is connected to the Crankcase Ventilation (CV) filter assembly. The CV outlet is open to atmosphere. This configuration is simple to install and is an effective oil mist removal system for applications which allow crankcase venting to atmosphere. The only routine maintenance required for the CV system is filter replacement. Typical service life of the high-performance filter in diesel applications is 750 hours. CV units are designed to handle various crankcase flow rates up to 50 CFM. Traditionally, the crankcase flow rate can be calculated as...

Open the catalog to page 8
Power Generation - 9

CCV Closed Crankcase Ventilation Systems Pop-up style indicator alerts of bypass condition and need for filter change. Unique crankcase pressure regulator with integral bypass valve minimizes variation in crankcase pressure. Excessive variation in crankcase pressure can damage seals, cause loss of oil, and other problems. Choose left or right-hand inlet. Available with or without bypass indicator. In a closed system, the contaminated crankcase gases flow from the engine breather into the CCV inlet. The contaminated crankcase gases flow underneath a valve diaphragm into the interior of the...

Open the catalog to page 9
Power Generation - 10

Remote Mount We've Bottled Racor Protection Racor Additives are performance-enhansing products for all climates and seasons. There are several convenient sizes, including a 16 oz bottle, 1 and 5 gallon containers, and a 55 gallon drum. The high concentration of active ingrediants in Racor Additives allows for higher treatment rates: Diesel Conditioner Plus+ 16 oz bottle treats 320 gallons Diesel Winter Plus+ 16 oz bottle treats 128 gallons Diesel Biocide 16 oz bottle treats 1280 gallons Diesel Performance Plus+ 16 oz bottle treats 80 gallons Gasoline Conditioner Plus+ 16 oz treats 320...

Open the catalog to page 10
Power Generation - 11

Caution for Users: Petroleum products flowing over a plastic surface generate static electricity. Caution should be taken to ensure that the RFF is grounded to reduce static electricity buildup and reduce the chance of explosions or fire. Electrically bond the funnel by using a wire with a metal clip on each end and clamp one to the upper rim of the funnel and the other to the fueling source. For example, the metal gas can or nozzle from the pump. RK 22628 Bowl Wrench Fuel Filter Funnels Racor Fuel Filter Funnel (RFF) is a new heavy-duty, fast-flow, filter-in-a-funnel that separates...

Open the catalog to page 11

All Parker Hannifin catalogs and brochures

  1. PS120 Series

    2 Pages

  2. P510MAM

    2 Pages

  3. Boiler Layup

    4 Pages

  4. Racor 7501

    32 Pages

  5. Racor 7609

    8 Pages

  6. Racor 7539

    40 Pages

  7. Racor 7637

    2 Pages

  8. Racor 7460

    20 Pages

  9. Racor 7815

    8 Pages

  10. RSL0075

    12 Pages

  11. Snapp series

    8 Pages

  12. clean dry fuel

    16 Pages

Archived catalogs

  1. 7807 Catalog

    32 Pages

  2. nofrills

    2 Pages

  3. WATER SERIES

    2 Pages