Catalog excerpts
Contamination Detection climate control process control sealing & shielding ENGINEERING YOUR SUCCESS.
Open the catalog to page 1Contamination Detection Systems Questions? Contact Technical Support: e-mail: racortech@parker.com
Open the catalog to page 2Contamination Detection Systems ico|jnt Partiele Monitoring Systems There are many reasons why the ACM20, portable particle counter, is a world-beater. Users are attracted the laboratory. Others recognise the manufacturing quality, reliability and the potential for improved monitoring of fuel supply systems that until now have required laboratory analysis to confirm contamination levels. Then there are those who find originality and innovation irresistible qualities that when combined provide a fluid condition monitor that will out- achieving full ISO certification and calibration to the...
Open the catalog to page 3Contamination Detection Systems ico|jnt Partiele Monitoring Systems real time. The ACM20 offersthe following user benefits: * Used in other applications such as filter performance, pipeline service intervals of supply • 300 downloadable test memory allowing for trend analysis and upkeep of statistical records to predict and save routine maintenance, resulting in less • Data retrieval of test results from memory via hand set display. • User friendly instrument improves familiarity and awareness of fuel • Primary output. Six cumulative particle size channels ranging from * Secondary...
Open the catalog to page 4Contamination Detection Systems ico|jnt Partiele Monitoring Systems Testing Set-up: The testing unit should be set up in accordance with manufacturers' operating instructions Test Preparation: Prior to starting a test, tumble the test portion end over end for 60 seconds to ensure any settled particles are Start Testing: Following the flush, start a test by turning the blue valve in the direction Test Portion: field sample into a clean test portion Flush System: Flush the equipment with the new test sample for 60 seconds prior to starting alternative method for use within aviation turbine...
Open the catalog to page 5Contamination Detection Systems icopnt Particle Monitoring Systems ACM20 Application Flow Chart Questions? Contact Technical Support: e-mail: racortech@parker.com
Open the catalog to page 6Contamination Detection Systems ico|jnt Partiele Monitoring Systems Adding to, and further enhancing the ACM product family, Parker's Condition Monitoring Centre has introduced an ATEX approved, ACM20Z2, Zone 2 accredited, particle be used to monitor various fuels from existing sampling points in hazardous locations from refineries, pipelines, distribution terminals, airport fuel supply systems all the way through to the point of uplift into aircraft. With is the worlds only ATEX approved portable particle counter. To count and verify the levels accordance with specification limits. •...
Open the catalog to page 7Contamination Detection Systems ico|jnt Partiele Monitoring Systems ACM20 Z2, with Zone 2 Classification, is the worlds one and only ATEX approved portable particle counter. certified stainless steel enclosure to comply with ATEX Directive 94/9/ hazardous areas, including • "A" Class product defined for the Aviation market. • ATEX approved Handset and * Suitable for use with mineral oil and petroleum based fluid as per • Primary Output. Six cumulative particle size channels ranging from • Secondary Diagnostic Output. Reporting % volume distribution, indicating presence of free water •...
Open the catalog to page 8Contamination Detection Systems ico|jnt Partiele Monitoring Systems icopntPD is a permanently installed W—y fuel contamination detector. refuellers and hydrant dispensers. The IPD provides cost effective, full flow monitoring and can interface with system data acquisition devices enabling continuous, remote monitoring and system shut down during a contamination event. Installed on the downstream side receives slipstream sampling from an existing Miflipore™ adaptor point. The real-time monitoring of the fuel passing through the sensor is reported to the on-vehicle data acquisition unit. In...
Open the catalog to page 9Contamination Detection Systems icopnt Particle Monitoring Systems • New and under development in • Field solution to Laboratory the detection of contaminates methods for the detection of solid distribution in various Aviation contamination and free water fuels. inference. Auxilary Flow Device: flow control device has been developed to give the IcountPD user greater flexibility. The flow control device will enble testing where flow ranges are outside (40-140 ml/min), or where pipe The flow control device fits onto the downstream (outlet) side through a manifold block, via a self-sealing...
Open the catalog to page 10Contamination Detection Systems ico|jnt Partiele Monitoring Systems The complete solution - industrial design combined with state of the The icountBS - Bottle Sampler from Parker with its innovative industrial design has been developed for customers looking for state of the art technology, attention to detail and laboratory particle analysis model. Combine this with on-board, laser based, leading edge technology to bring to all industries a truly revolutionary Particle Counter. The icountBS is a product from the next generation of Parker's fluid particle analysis and monitoring innovations....
Open the catalog to page 11Contamination Detection Systems icopnt Particle Monitoring Systems Average Particle Counts This table gives estimated counts found in a typical aviation fuel distribution system, and is given as guidance, in which APR/EI filtration equipment is Into Micro Filter Into Plane Questions? Contact Technical Support: e-mail: racortech@parker.com
Open the catalog to page 12Contamination Detection Systems Part Number Index PRODUCT PAGE# PRODUCT PAGE# Questions? Contact Technical Support: e-mail: racortech@parker.com
Open the catalog to page 13Contamination Detection Systems _______________________________________________________________________________________ _______________________________________________________________________________________ _______________________________________________________________________________________ _______________________________________________________________________________________ _______________________________________________________________________________________ _______________________________________________________________________________________...
Open the catalog to page 14All Parker Hannifin catalogs and brochures
-
PS120 Series
2 Pages
-
P510MAM
2 Pages
-
Boiler Layup
4 Pages
-
Wine Industry
2 Pages
-
Mechanical Gas Seals
4 Pages
-
Chemical Tank Blanketing
4 Pages
-
Power Generation
12 Pages
-
Railway Industry
8 Pages
-
Bus and Coach Products
4 Pages
-
Racor EB00007
2 Pages
-
Racor 7501
32 Pages
-
Racor 7609
8 Pages
-
Racor 7539
40 Pages
-
Racor RSL0279
2 Pages
-
Racor RSL0183
4 Pages
-
Racor 7637
2 Pages
-
Racor 7460
20 Pages
-
Racor 7815
8 Pages
-
RSL0075
12 Pages
-
Crankcase Ventilation
12 Pages
-
SNAPP Marine
1 Pages
-
Marine Filtration Systems
36 Pages
-
Snapp series
8 Pages
-
clean dry fuel
16 Pages
-
Racor Engine Air Overview Guide
40 Pages
-
Racor Marine Clean+
2 Pages
-
Bilge Adsorbent Separator
2 Pages
-
Racor Village Marine Watermakers
28 Pages
Archived catalogs
-
7807 Catalog
32 Pages
-
Additive Brochure
6 Pages
-
nofrills
2 Pages
-
BILGE WATER TREATMENT
2 Pages
-
INDUSTRIAL SERIES
2 Pages
-
WATER SERIES
2 Pages
-
Marine applications
8 Pages
-
FilterPump Brochure
2 Pages