PARAT IEH
7Pages

{{requestButtons}}

Catalog excerpts

PARAT IEH - 1

High Voltage Electrode Boiler From POWER to HEAT for Steam or Hot water

Open the catalog to page 1
PARAT IEH - 2

From renewable POWER to HEAT with PARAT electrode boiler PARAT; boilers since 1920 Our electrode boiler has been designed and developed by our inhouse engineers and manufactured in our workshop in Norway since 1990. Our boiler history goes all the way back to 1920. Thanks to our long experience, we where chosen to deliver the first steam boilers for Grid Regulation in the World. Steam and hot water The electrode boiler is delivered both in steam or hot water versions. Renewable energy can be used in steam grids and district heating networks. The electrode boiler is also a valuable backup...

Open the catalog to page 2
PARAT IEH - 3

Grid Regulation The growing production of renewable power from sun and wind gives more and more often excess power in the grid. This power must be used, to stabilize the frequency of the current at 50 Hz. This is called grid frequency regulation. Electrical grid regulation Since electrical power will be available as a fuel in the future, the PARAT Electrode boiler will also be a valuable backup boiler in case of breakdown in the fired boilers or in the fuel distribution system. SRL Signal from Grid Control Required Boiler Load Actual Boiler Load Backup boiler Increasing power generation...

Open the catalog to page 3
PARAT IEH - 4

Steam Grid Infraserv Höchst, Frankfurt Steam Solutions A steam grid is the perfect place to use excess power from renewable energy. When the electrode boiler runs, the traditional boilers can decrease their load and fossile fuel be saved. STEAM OUTLET PRESSURE SAFETY VALVE PRESSURE CONTROL Steam is produced in the water between the electrodes. The internal circulation system brings water to the electrodes in a ratio 10:1 for the evaporation. The output is controlled by a throttle valve that regulates the level in the upper chamber. Steam accumulates in the upper part of the pressure vessel...

Open the catalog to page 4
PARAT IEH - 5

Heat Storage District Heating Coca Cola Enterprises, Norway Hot Water A district heating network will always have the possibility to receive excess power from renewable energy. When the electrode boiler runs, the traditional boilers can decrease their load and save fossile fuel. PRESSURE SAFETY VALVE N2 PRESSURE CONTROL If temperature delivered to the client exceeds the setpoint, power of the boiler is automatically decreased. The output is controlled by a throttle valve that regulates the level in the upper boiler chamber. PRESSURE SAFETY TEMPERATURE CONTROL TEMPERATURE CONTROL By...

Open the catalog to page 5
PARAT IEH - 6

From cold to full load in less than 5 minutes 30 seconds from minimum to full load minimum load 0% no earth current Compact design - up to 60 mUJ in one unit no low voltage transformer required no Electrode wear minimum maintenance required Design codes We deliver the boiler CE marked according to PED/97/23/EC with boiler code EN12953. ASME stamp can be delivered as an option. The Electrode boiler is also available in EX version for installation in zone 2 hazardous areas. The Medium Voltage connection cell is designed according to EN 61936-1 for power installations. Technical Specifications...

Open the catalog to page 6

All Parat Halvorsen AS catalogs and brochures

  1. Marine Boilers

    21 Pages

  2. PARAT MEH

    2 Pages

  3. PARAT M CS

    2 Pages

  4. PARATMEL-C

    2 Pages

  5. PARAT MTW

    2 Pages

  6. Parat MFC

    2 Pages

  7. PARAT MES

    2 Pages

  8. PARAT MEW

    2 Pages

  9. PARAT MVS

    2 Pages

  10. PARAT MSH

    2 Pages

  11. PARAT MVW

    2 Pages

  12. PARAT MKS

    2 Pages

  13. PARAT MPW

    2 Pages