The OxyGuard Oxygen Probe Probe for High and Low Levels of both Dissolved and Gaseous Oxygen The OxyGuard Probe is a membrane covered galvanic cell that generates an electrical signal proportional to the oxygen pressure it senses, no matter whether it is in water, air, gas, wine, oil or something else. The probe can be used to measure dissolved oxygen in aquaculture, the environment, in clean water, waste water and in oil or other fluid. It can measure very small oxygen concentrations in inert or explosive gases as well as the oxygen content of ambient air and the purity of oxygen gas. The chemistry and construction of the OxyGuard Probe of today represents a third-generation development of the OxyGuard probe. It incorporates significant improvements over the original OxyGuard probe that revolutionized dissolved oxygen measurement. Not only does the OxyGuard probe use a better chemistry than traditional membrane-covered oxygen probes, but the chemistry has now been refined. This, together with an improved mechanical design, give an even better accuracy and long-term stability. The OxyGuard probe acts as a battery that gives a direct measurement of the oxygen contration it is subjected to. The more oxygen there is outside the probe, the more oxygen can diffuse through the membrane to carry electrons between the anode and cathode to make the output signal. An OxyGuard probe needs neither an applied voltage nor microprocessor controlled electronics in order to work. It measures oxygen all the time, and continues to do so until all the anode metal has been converted to metal oxide, which takes about 30 years. In practical use in Aquaculture the OxyGuard probe can keep calibration for about 1 year, and operate for 3 to 5 years before membrane replacement is needed. The latter procedure is easy and costs very little.
Open the catalog to page 1Specifications Dimensions: Weight: Principle: Range and Output: Flow Requirements, water: Operating Conditions: Standard Accessories: Diameter = 58 mm, length = 59 mm. Cable length = 7 m (standard). 0.2 kg without cable,0,5 kg with 7m cable. Galvanic cell, self polarizing, self temperature-compensating. 2.5 to 5 millivolts per ppm (mg/l). Output impedance approx. 1 kiloohm. Minimum flow dependent on DO and temperature, typically 1 cm/sec. 0 to 40°C. Submersible to 50 metres. As standard 5 spare membranes with O-rings, 50 ml electrolyte and a cathode cleaning pad are shipped with each probe....
Open the catalog to page 2All OxyGuard International A/S catalogs and brochures
-
POLARIS
2 Pages
-
OxyGuard CO2
2 Pages
-
Pond Master
4 Pages
-
Model 420
2 Pages
-
Model 505
2 Pages
-
model 525
2 Pages
-
Ocean Probe
2 Pages