DAMPERS

DAMPERS
1 / 13 PagesView full catalog

DAMPERS

Product catalog summary
Overview: This document provides technical specifications and applications for various types of dampers manufactured by Nyborg AS, a company based in Sykkylven, Norway. The dampers are used in ventilation systems for controlling air flow and preventing backflow.
Types of Dampers:
  • LSS / SOD: Circular single blade shut off damper, suitable for non-weather tight applications, often mounted directly to fans or hoods. It offers low pressure drop and is suitable for high air speed applications.
  • SSVent: Rectangular multiblade shut off damper with circular adapter, used for medium to bigger fans. It can be mounted directly on bulkheads or in rectangular ducts.
  • S.Ventil R1OVL: Circular single blade weather tight damper/valve.
  • RD: Circular regulating damper, typically installed at fan inlets for regulating air flow.
  • BFD: Back flow (non-return) damper, used to prevent backflow in systems with parallel fans.
  • BSS: Combined fire damper with silencer, available in classes A0 and A30.
Material and Construction:
  • Dampers are constructed using materials such as mild steel, AISI 316L stainless steel, and hot dip galvanized steel. Optional materials include AISI 316L or aluminum for casing and blades.
  • Special designs include short casing, combined damper with circular silencer, and thick-walled casing for high vertical loads.
Actuation and Options:
  • Manual actuation is standard, with options for pneumatic or electric actuation (24-230V), suitable for safe areas or EX zones 1 or 2.
  • Additional options include external limit switches, junction boxes, extended manual arms, and special flange standards.
Performance Data:
  • Maximum pressure and air speed vary by damper size, with specific pressure drop coefficients provided for different sizes.
  • Blade leakage is classified according to EN1751:1998 standards.
Installation and Special Features:
  • Dampers can be installed vertically or horizontally, with specific designs for marine applications.
  • Special features include regulation possibilities, low or high temperature operation, sealing gaskets for low leakage, and special coatings for outdoor mounting.
Conclusion: Nyborg AS offers a range of dampers designed for various applications in ventilation systems, with customizable options to meet specific requirements. The document provides detailed specifications and options for each type of damper, ensuring suitability for different operational environments.
See more

Catalog excerpts

DAMPERS-1

LSS / SOD – circular single blade shut off damper SSVent – rectangular multiblade shut off damper S.Ventil R1OVL – circular single blade weather tight damper/valve RD – circular regulating damper BFD – back flow (non return) damper BSS – combined fire damper A0, A30 with silencer

 Open the catalog to page 1
DAMPERS-3

NYBORG CIRCULAR SHUT OFF DAMPER APPLICATION Used as shut off damper (for non weather tight applications) often mounted directly to fans or hoods. Single blade damper gives low pressure drop, and is suitable for applications with high air speed. Can also be used as regulating damper. Typically used for small to medium fan sizes. SPECIAL DESIGN  Short casing (damper popping out of one or two side of damper)  Combined damper with circular silencer.  With thick walled casing for high vertical loads /open deck mounting. EXECUTION Casing/housing made of mild steel, hot dip galvanized. Damper blade...

 Open the catalog to page 3
DAMPERS-4

NYBORG CIRCULAR SHUT-OFF DAMPER DAMPER HOUSING, DAMPER PLATE, OPERATING FIELD, OPERATING HANDLE, DAMPER SHAFT, Matl. : St.37, Hot Dipped Galvanized Matl.: AISI 316L c/w open/closed Indicator c/w Clamping Screw and Wing Nut Matl. : AISI 316L To be equipped with actuator (pneumatical or electrical) up to size Ø 630 DIA

 Open the catalog to page 4
DAMPERS-5

NYBORG CIRCULAR SHUT OFF DAMPER APPLICATION The SSVent is a rectangular multiblade shut off damper with circular adapter for mounting directly to axial fan or circular duct. It can also be mounted directly on bulkhead or in rectangular duct. Additional to shut off damper it can also be used as a regulating damper. Suitable for medium to bigger fans ACTUATOR: Electric 24-230V (non EX and EX for zone 1 or 2), pneumatic (non EX and EX for zone 1 or 2) or manual actuator. All electric or pneumatic actuators fail safe and with limit switches as standard. Pneumatic actuators also with solenoid valve...

 Open the catalog to page 5
DAMPERS-6

NYBORG RECTANGULAR SHUT-OFF DAMPER NYBORG RECTANGULAR SHUT-OFF DAMPER, DESIGNED FOR CIRCULAR APPLICATION, SSVent BxH, made of hot dipped galv. Steel. Damper blades and shafts in AISI 316L. Adapterplate is made of hot dipped galv. steel. Equipped with electrical or pneumatical actuators.

 Open the catalog to page 6
DAMPERS-7

BACK FLOW DAMPER APPLICATION The back flow (or non return) damper is used in ventilation system where back flow or return air is to be prevented. Typically used for two fans in parallel (one running, one standby) to prevent backflow over idle fan. The damper is fully mechanically, opening on air flow, closing on gravity. SPECIAL DESIGN Can be made with smaller depth (200 and 250 mm) if space is limited. INSTALLATIONS  Vertical (for horizontal air flow)  Horizontal, air up  Horizontal, air down (should be used with caution) EXECUTION Designed for marine application. Standard execution in aisi316L,...

 Open the catalog to page 7
DAMPERS-8

BACK FLOW (NON RETURN) DAMPERS Performance data at 20⁰C., r = 1,205kg/m3 Damper Data Max pressure 4000Pa (higher pressures on request) Operating temperature -25 to +60C (lower and/or higher temperature optional) aisi316L (aisi304, alum or hot dip galvanized as option) Closed damper blade leakage Material frame Earthing boss Standard, on lenkage arm side Material blades Left side seen from outlet Regulating possibility Position indicator Vertical, horizontal (air up) or horizontal (air down) Damper Pressure drop 160 Static pressure drop, [Pa] Air speed, [m/s] Pressure drops for sizes 300mm x 300mm...

 Open the catalog to page 8
DAMPERS-9

Back Flow Damper Damper to be made in custom made sizes BxH Frame – optional material: AISI316L Optional flange standard: acc. to ISO 15138 Optional – counter weights for balanced damper Installations: Vertical (horizontal air flow) Horizontal (vertical air flow, up) Horizontal (vertical air flow, down) Max width of damper, normal design 1500mm Item 1 2 3 4 Description Blade Assembly Housing Indicator Earthing Stud Material AISI 304/316L Mild Steel, HD Galvanized AISI 304/316L Mild Steel, HD Galvanized

 Open the catalog to page 9
DAMPERS-10

WEATHER TIGHT BUTTERFLY VALVE with drain gap for overflow water

 Open the catalog to page 10
DAMPERS-11

FIRE DAMPER BSS 250÷1400 R-LD, R-LD-SK Class: A-0, A-15, A-30 T A 1 DAMPER HOUSING, Matl.: St37, Hot Dipp Galvanized 2 DAMPER BLADE, 4 ACTUATOR, Pneumatic, spring-return 5 TERMINAL BOX, 6 Thermoelectric SENSOR, 72°C 7 INSULATION, Matl.: Mineral Wool Draw. no.: 4-50007 Date: 2015-01-21 Drawn: A. Świeca Order example: BSS 710 R-LD / A-30 710 – Diameter / Length R-LD – Mounted on a deck R-LD-SK – Mounted on a bulkhead A-30 – Class acc. to FTP Code G

 Open the catalog to page 11
DAMPERS-12

REGULATING DAMPER Manually Controlled Regulating dampers are normally installed at fan inlet for regulating of air flow. The damper will give symmetrical inflow to the fan. Aplication for Vertical or Horizantal installation. EXECUTION: - Stainless steel AISI 304 or AISI 316L, or optional painted carbon steel (not recomended for marine application) - Flange: hole pattern acc. to ISO 15138 - Standard execution (45 °C) or Heat resistant (up to 350 °C) - Option: heavy flange (in case of heavy vertical load) When ordering, please state the following data: impeller rotation direction: Right (RD) or...

 Open the catalog to page 12
DAMPERS-13

REGULATING DAMPER Servomotor Control Regulating dampers are normally installed at fan inlet for regulating of air flow. The damper will give symmetrical inflow to the fan. Aplication for Vertical or Horizantal installation. EXECUTION: - Stainless steel AISI 304 or AISI 316L, or optional painted carbon steel (not recomended for marine application) - Flange: hole pattern acc. to ISO 15138 - Standard execution (45 °C) or Heat resistant (up to 350 °C) - Option: heavy flange (in case of heavy vertical load) When ordering, please state the following data: impeller rotation direction: Right (RD) or...