Product catalog summary
General Introduction
The document provides detailed instructions for the installation and maintenance of Novenco Climaster ZCR air handling units, including the unit casing and components.
Handling
  • Weight: Weight and dimensions are detailed in the dimension drawing and weight lists.
  • Assembled Units: Transport using cranes or forklifts, ensuring proper handling to avoid damage.
Reception on Site
Inspect the unit for transportation damage and completeness upon arrival. Report any issues immediately.
Storage
Units are delivered in plastic packaging. For electric heating coils, maintain storage conditions below 60% humidity and above 15°C. Long-term storage requires indoor, dry, and ventilated conditions.
Installation and Alignment of Base Frame
  • Pipe Layout: Ensure pipes do not obstruct access or operation.
  • Electric Connections: Use cable glands for airtight connections and follow safety regulations.
  • Duct Connection: Use LS-cleats for connecting ducts, with optional flexible connections available.
  • Water Trap: Install water traps for sections with cooling coils to prevent leaks.
Description of Unit Casing
  • Panels and Doors: Constructed for easy cleaning and maintenance, with adjustable doors for access.
  • Cleaning and Leakage: Regular cleaning and inspection for leaks are essential.
  • Material Description: Details on materials used for construction, including Alu-Zinc and stainless steel.
Dampers
Maintenance-free design with instructions for mounting damper motors and ensuring proper lubrication.
Filters
  • Types and Maintenance: Various filter types are used, with guidelines for replacement and pressure drop monitoring.
  • Life and Pressure Drop: Regular checks are advised to maintain system efficiency and hygiene.
Rotary Wheel Type Heat Exchanger
Instructions for drive system maintenance, rotor adjustments, and cleaning.
Heating and Cooling Coils
Guidelines for pipe connections, cleaning, and frost protection, along with thermostat checks.
Fans
Details on storage, electric connections, and maintenance for different fan types, including centrifugal, ZerAx, and plug fans.
Motors for Fans
Instructions for connecting and maintaining fan motors.
Spare Parts
List of available spare parts for various components.
EC-Declaration of Conformity
Compliance information for the ZCR units.
Filter Replacement and Ordering
If the filter pressure exceeds 300 Pa, it needs replacement. Contact Novenco for ordering the correct filters, specifying the type such as panel, pocket, aluminum, or compact filters.
Rotary Wheel Type Heat Exchanger
This system includes a rotor and drive system with internal ball bearings. The rotor is secured to the casing with screws and an adjusting disc. Brush seals are used to prevent air leakage, with specific configurations for different models (ZCR 9/6 to 18/15). The drive system can be a geared motor for constant speed or an EMS system for automatic operation.
Drive System
The EMS system includes features like automatic purging, rotation guard, and alarm relay. It requires a 230V connection and is maintenance-free. The rotor's position should be checked and adjusted if necessary to ensure proper alignment.
Purging Sector
Adjust the purging sector based on system pressure to prevent leakage of polluted air. The sector can be set in seven positions, with specific settings based on differential pressure.
Rotor Bearings and Belt Drive
Bearings are non-re-greasable and should be replaced when worn. The belt drive is maintenance-free, but a spare belt should be available.
Cleaning and Inspection
Regular cleaning of the rotor is necessary to maintain performance. Inspection is recommended when changing filters.
Heating and Cooling Coils
These consist of copper tubes with aluminum fins. They must be connected in counter flow and kept clean to ensure efficiency. Cleaning should be done carefully to avoid damaging the fins.
Frost Protection and Electric Heating Coil
Coils must be protected against frost by maintaining water flow. The electric heating coil includes thermostats for temperature control and safety functions to prevent overheating.
Fans
The ZCR unit can be equipped with centrifugal, ZerAx, or plug fans. Proper storage and maintenance are essential for optimal performance.
Specifications and Procedures
  • Storage and Handling: For storage longer than 6 months, loosen the V-belt drive. Regularly turn the impeller by hand.
  • Electric Connections: Must be performed by authorized personnel following current regulations. Use approved rubber cables and ensure proper grounding. Establish a lockable maintenance switch outside the air handling unit.
  • Start-up of Fan: Remove transport protection, ensure free rotation of fan impellers, and check for foreign bodies. Verify electrical connections, belt tension, and alignment. Conduct a test run to ensure correct rotation direction and check for abnormal sounds or vibrations.
Inspection and Maintenance
  • General Inspection: Conduct bi-annual checks for abnormal noises and vibrations. Clean dust or dirt accumulations to prevent vibrations.
  • Centrifugal Fans: The fan unit includes a double inlet centrifugal fan, motor, and V-belt drive. Ensure proper attachment and alignment of components.
  • Dismounting and Servicing: Cut off power before servicing. Remove screws and flexible connections to pull out the fan unit.
  • Tensioning and Belt Changing: Follow safety measures and use a torque wrench for proper alignment. Regularly check belt tension and alignment.
Technical Data and Recommendations
  • Fan Bearings: Detailed specifications for various fan types, including maximum RPM, power, and bearing types.
  • Change of Bearings: Follow specific procedures for dismounting and replacing bearings.
  • ZerAx Fans: Specific instructions for dismounting and servicing ZerAx fans, including safety precautions and handling guidelines.
Key Tables and Figures
  • Tightening Torques: Detailed table of TB bushes, Allen screws, and tightening torques.
  • Belt Tension Values: Comprehensive table for Optibelt V-belts, including static tension and maximum shaft load values.
Fan Unit Installation and Maintenance

Mounting the Fan Unit:
1. Connect the motor cable in the terminal box.
2. Position the fan unit and secure it with screws in the bearings.
3. Install the rails for the rubber cloth.
4. Secure the flexible connection between the panel and fan.
5. Close and lock the fan section door using the square key.
Air Quantity Meter:
The air quantity meter includes a pressure probe at the fan inlet and a manometer outside the fan section. Calibration involves ensuring the manometric liquid is in the measuring vessel, adjusting the measuring vessel to zero on the pressure scale, and securing the screws. The air quantity is calculated using the formula q = 1/k -- pt, with calibration values provided for different fan types.
Plug Fans:
Plug fans are direct-driven, single-inlet centrifugal fans with backward-curved blades. They are mounted with vibration dampers and connected to the motor via a terminal box. The fan is isolated with a flexible hose to prevent vibration transmission.
Dismounting the Fan Unit:
1. Turn off the air handling unit and lock the safety switch.
2. Wait two minutes before opening the doors.
3. Remove screws fastening the fan unit to the rails.
4. Release the fan unit from the discharge panel and support it.
5. Disconnect the motor cable in the terminal box.
Mounting the Fan Unit:
1. Place the fan unit on the rails.
2. Center the fan unit in front of the discharge panel.
3. Secure flexible connections with screws.
4. Close and lock the fan section door.
Motors for Fans:
Fan motors are pre-mounted but not electrically connected. Bearings should be lubricated as per manufacturer instructions.
Parts List:
Includes various components such as louvre dampers, filters, and fan parts with specific part numbers and sizes.
EC-Declaration of Conformity:
Novenco air handling units comply with EC Machinery Directive 2006/42/EC and other relevant standards, provided installation instructions are followed.
Company Information:
Novenco, founded in 1947 in Denmark, is a leading supplier of ventilation and firefighting systems, certified to ISO 9001 and ISO 14001 standards.
See more

Catalog excerpts

ZCR-1

Novenco Air Handling Units Climaster ZCR – Installation and maintenance

 Open the catalog to page 1
ZCR-3

Novenco Climaster ZCR 1. General Introduction 2. Handling 2.1 2.2 Weight Assembled units Adjustment of rotor Purging Sector Rotor bearings Belt drive Cleaning Inspection 3. Reception on Site 10. Heating and Cooling Coils 4. Storage 5. Installation and Alignment of Base Frame 5.1 5.2 5.3 5.4 Pipe layout Electric connections Duct connection Water trap Panels Doors Cleaning Leakage Conditions near the air handling unit Surface treatment Material description Mounting of damper motors Maintenance Damper motors Filter guard Change of filter/cleaning Life Recommended final pressure losses for filters...

 Open the catalog to page 3
ZCR-4

Novenco Climaster ZCR 1. General Introduction The instructions describe installation and maintenance of both unit casing and all components, which may be included in the unit. Therefore, components, which are not included in the current unit, will also be described in the instructions. In the table of contents all sections are described and numbered, and both installation and maintenance instructions are collected under one heading. 2. Handling 2.1 Weight The total weight and dimension are stated on the dimension drawing and weight lists. 2.2 Assembled units An assembled unit type ZCR can be...

 Open the catalog to page 4
ZCR-5

For storage longer than 6 months, Vbelt drive should be loosened. Air Handling Units are not to be used as working platforms. If access to the roof is unavoidable the roof should be covered with sheet plywood. In addition protection should be provided to junction boxes, door handles, dampers etc. to avoid them being used for climbing. 5 Installation of Base Frame The air handling units are provided with a base frame onto which the sections are assembled, mounted and fixed with bolts. The base frame consists of two longitudinal girders stabilized by transverse girder stiffeners. 5.2 Pipe layout...

 Open the catalog to page 5
ZCR-6

ball so that it is tight also without being filled with water. Connect the water trap to the drain from the drip pan of the unit. All drains from drip pans in the unit are with thread (1½" BSP male). In order to work, the height of the water in the water trap (H-measurement) must be higher than the pressure height in the unit (Dp inside/ outside in the unit at the water trap). Example.: Dp = 1300 Pa. The Hmeasurement must be at least 130 mm and to this must be added the increased pressure loss for fouling of the filters and also 10 mm for safety: minimal 300 Pa corresponding to 30 mm. This results...

 Open the catalog to page 6
ZCR-7

it is necessary to replace the adhesive sealing strip. Pipe and cable inlets must be leakage-free. Check at intervals that duct connections and flexible connections are leakage-free. 6.5 Conditions near the air handling unit Air intake must be kept free of foreign material (paper, leaves etc.). Recommended cleaning intervals (Please see the individual components as well): General inspection: Once a month. Minor internal cleaning: First time after 1 month of operation. Afterwards every third month. Filter check: First time after 1 month of operation. Afterwards every third month. Check of remaining...

 Open the catalog to page 7
ZCR-8

7.2 Maintenance In practice the SJD damper is maintenance-free, but make sure that the damper is kept clear of dust and dirt. This applies to both air path and regulating mechanism outside the air path. The damper regulating mechanism must always be well greased, e.g. with graphite grease, where moving metal parts slide against each other. Pay especially attention to this if the air stream has a degreasing effect. supplemented by a pre-filter of the basic filter type. The filters, marked with type, are inserted in retainers and fastened by means of locking rails which press the filter frame against...

 Open the catalog to page 8
ZCR-9

8.5 Replacement filters Contact Novenco for ordering correct filters. - Filter type order No. 9. Rotary Wheel Type Heat Exchanger Panel filters Pocket type filter The rotary wheel type heat exchanger consists of a rotor and a drive system. The rotor has internal ball bearings and is fastened to the casing by screws through an adjusting disc (eccentric), a slot in the frame and a disc at the end of the shaft fig. 9.1. and 9.2. Location of brush seal, purging sector, measuring taps and a drive system Compact filter Aluminium filter In ZCR 9/6 to 13/8 the brush strip forming the seal along the circumference...

 Open the catalog to page 9
ZCR-10

seal at the discharge side of the fresh The purging sector and drive system are located as shown on the sketches tary wheel type heat exchanger. The drive system is as standard a geared motor for constant rotor speed. Alternatively, a system for automatic control of the motor speed, i.e. for operation with varia- ble speeds, can also be delivered. The drive system is mounted in the return air part of the rotary wheel type heat exchanger. Fig. 9.3 and fig. 9.4 control box and motor are located EMS system for automatic opera- tion of the rotor is easy to use as the drive system does not require...

 Open the catalog to page 10
ZCR-11

If the gap is not exactly the same along the whole circumference of the rotor, it must be adjusted: Remove cover above adjusting screw, fig. 9.5. Loosen screw in shaft end and adjust rotor by means of the adjusting disc till gap between rotor and casing is exactly the same along the whole circumference of the rotor, fig. 9.6. In ZCR 9/4 up to and including 18/ 10 the wrench opening is 32 mm for the adjusting disc. In ZCR 18/12 and 18/15 the wrench opening is 41 mm. After adjustment remount cover above adjustment disc, fig. 9.5. Check at suitable intervals during the working period that brush...

 Open the catalog to page 11
ZCR-12

9.5 Rotor bearings The rotor bearings are ball bearings which cannot be re-greased. When the working lives of the bearings have come to an end, they must be replaced. The replacement should be carried out by a serviceman. 9.6 Belt drive The belt drive has an elastic belt which does not require any maintenance. The elasticity of the belt is referred to as belt tension. The rotor can be provided with a spare belt, if ordered when ordering the unit. If the belt bursts, use the spare belt and provide the rotor with a new spare belt at the first opportunity. This work should be carried out by a serviceman...

 Open the catalog to page 12

All Novenco catalogs and brochures

  1. NovPac-R

    2  Pages

  2. ZPR

    2  Pages

  3. Super Speed

    2  Pages

  4. workboats

    4  Pages

  5. navy system

    4  Pages

  6. FLEXAIR

    8  Pages

  7. ZerAx axial

    20  Pages

  8. MICROVENT

    8  Pages

  9. CND and CNF

    24  Pages

  10. MICRO VENT

    8  Pages

  11. NOVPAC R

    2  Pages

  12. CNA-CNB

    20  Pages

Archived catalogs

  1. Navy System 1

    4  Pages

  2. ACN

    28  Pages

  3. CAL

    40  Pages

  4. VMA-VMB

    24  Pages

  5. SJD

    12  Pages

  6. ZCP

    36  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.