Novenco's Novax axial flow fans are versatile, designed for both standard and hot smoke applications with presettable blades. They are suitable for various installations including duct (ACN), free intake with duct connection (ACG), and wall/bulkhead mounting (ACP). These fans are integral to comfort and industrial ventilation systems, particularly for hot smoke removal during fires.
Specifications
The Novax series offers 14 sizes for standard fans and 12 for hot smoke fans, with rotor diameters from Ø250 to Ø1600 mm and hub diameters from Ø160 to Ø578 mm. Airflow rates range from 0.1 to 65 m³/s, with pressure increases up to 2000 Pa.
Motor and Material Details
Motors adhere to IEC-72 and IEC-34 standards, with IP-55 or IP-54 enclosures and insulation classes B, F, or H. Blades are made from aluminum or GRP, with hot smoke fans using aluminum exclusively. The housing is made from hot-dip galvanized sheet steel.
Classifications and Standards
Fans comply with BS 848:1980 and ISO 5801:1997 standards, suitable for low-corrosion environments (DS/EN ISO 12944-2, Corrosion category C3). They operate in temperatures from -20 to +40 °C, with a maximum range of -40 to +120 °C. Hot smoke fans are F300 and F400 approved per EN 12101-3.
Accessories
Available accessories include mounting feet, intake funnels, flexible connections, silencers, acoustic diffusers, and anti-vibration mountings.
Performance and Regulation
Fans are equipped with 50 Hz motors, with options for 60 Hz and frequency regulation. Frequency inverters allow for speed control, maintaining efficiency up to 83%. Hot smoke fans must bypass frequency inverters during fires.
Type Descriptions
  • ACN: Designed for duct installation, featuring cylindrical housing and high efficiency due to a welded motor mount.
  • ACG: Suitable for connection to ducts, with a tubular housing and funnel-shaped inlet.
  • ACP: Intended for wall mounting, with a short tubular housing and direct air intake.
Conclusion
Novenco's Novax fans provide robust, reliable solutions for various ventilation needs, focusing on efficiency and adaptability to different environments and requirements.
Performance Curves for ACN, ACG, and ACP at 50 Hz
Performance curves for different fan types (ACN, ACG, ACP) at various RPMs (725, 970, 1470, 2900) show total pressure (Pa) against airflow rate (m³/s). The data is based on fan installation according to BS 848 1980 standards, with specific installation types affecting results. Final dimensioning and calculations are available on Novenco’s website.
Dimensions and Weights
Dimensions for ACN, ACG, and ACP fans are provided in millimeters, with weights in kilograms. The document details hub diameters, motor sizes, and installation sizes for rotor diameters ranging from Ø250 to Ø1600.
Accessories
Details on mounting feet and diffusers for ACN, ACG, and ACP fans are included. Dimensions and weights for mounting plates, horizontal mounting feet, and diffusers are specified. Information on guard meshes, intake funnels, mating flanges, duct bosses, flexible connections, and welding sockets is also provided.
Silencers, Hoods, and Dampers
Technical data for silencer type YAH, hood type HAN, and damper type SBC are provided, including dimensions, weights, and pressure loss calculations for silencers with and without cores. Average values for silencing across different octave bands are included.
Acoustic Diffuser Type YAD
The YAD acoustic diffusers are designed for comfort and industrial ventilation, available in sizes from Ø250 to Ø1600 mm, suitable for temperatures ranging from -40 to +120 °C.
Specifications
The document outlines specifications for Novax axial flow fans, including compatibility with corrosion classes C1, C2, C3, and optionally C4 with improved surface treatment. It also details the acoustic diffuser type YAD, providing octave band sound data and silencing values.
Acoustic Diffuser Type YAD
Detailed sound data for the YAD diffuser across various octave bands (63 Hz to 8 kHz) with and without the diffuser is provided, including measurements for different external and hub diameters.
Dimensions and Weights
Dimensions and weights for the YAD diffuser are provided, including hub sizes, fan side, and duct side measurements, along with weight specifications for various sizes.
Brass Lining for ACN
Details on installation sizes for rotor diameters and brass lining specifications are provided, including minimum blade clearance and weights. Special tape is applied to prevent galvanic corrosion.
Calculations and Efficiency
The document explains the basis for fan dimensioning and efficiency improvements through the use of diffusers. It includes formulas for calculating pressure and power consumption, highlighting the benefits of using long diffusers to save energy.
Formulas for Pressure
Formulas are provided for calculating static and dynamic pressures for different fan arrangements (A, B, C, D), along with explanations of symbols and units.
Run-up Time
The run-up time for axial flow fans is calculated using a specific formula, considering motor torque variations and polar moments of inertia.
Company Information
Novenco A/S is a Danish company specializing in ventilation and firefighting systems, certified under ISO 9001 and ISO 14001. The company emphasizes quality and environmentally friendly products.
See more

Catalog excerpts

ACN-1

Novenco Axial Flow Fans Novax — Standard and hot Smoke September 2006

 Open the catalog to page 1
ACN-2

Product Facts Axial flow fans with presettable • ACG free intake with connec- Novax axial flow fans are used for standard installations in connec- tion with comfort and industrial ventilation including removal of hot smoke in case of fire. The series of Novax axial fans is of- fered in 14 sizes with rotor diame- standard fans and in 12 sizes with rotor diameters from 0400 to There are seven sizes of hub diam- both types of fans. The air flow rates run from 0.1 to 65 m /s with increases in pressure from 0.2 to 65 m /s with increases smoke fans. Motor Sizes Number of Blades according to Hub Important...

 Open the catalog to page 2
ACN-3

Type Descriptions Overview of Types and Accessories This document is provided 'As is' and is subject to change without notice. Novenco reserves this right due to continuous product de- Novenco is a trademark of Novenco. Other trademarks appearing in this document are the property of their respective owners.

 Open the catalog to page 3
ACN-4

Novax are compact, robust, series-produced axial flow fans with presettable blades. Novax fans are installed in a wide range of ventilation systems on shore and off-shore: Comfort systems, in- dustrial, process, parking and tunnel ventilation as well as environment-enhancement systems. The fans require little space, are easy to install and offer high operational reliability. The Novax rotor consists of a pressed, two-part, as- sembled hub with depressions in which the blades are fixed. The rotor is provided with a hub boss on one side for mounting on a motor. The rotor blades can be fixed steplessly...

 Open the catalog to page 4
ACN-5

The fans are supplied with 50 Hz motors as standard, but can also be supplied with 60 Hz motors. Alterna- tively, they can also be speed controlled by means of frequency inversion with the maximum speeds indi- cated in the table below. Nominal RPMs for 50 Hz motors are found in the per- formance curves on pages 10 through 15. Thus Novax fans are a serious alternative to centrifu- gal fans in ventilation and air conditioning systems with varying air flow rate requirements. Using frequency inverters removes the limitations Thus axial fans can virtually always be placed within the maximum efficiency...

 Open the catalog to page 5
ACN-6

Type Descriptions The ACN range of axial fans comprises 14 installation sizes with rotor diameters from 0250 to 01600 mm for standard fans and 12 installation sizes with rotor There are seven hub diameter sizes from 0160 to Air flow rates run from 0.1 to 65 m3/s and pressure in- creases up to 2000 Pa for standard fans and from 0.2 to 65 m /s with pressure increases up to 1800 Pa for As hot smoke fans the range is F300 and F400 ap- proved according to EN 12101-3 to run for at least The fan housing is cylindrical with connection flanges The fan housing has a welded motor mount of sheet steel that...

 Open the catalog to page 6
ACN-7

let side of the rotor, enabling the ACG to achieve a very high efficiency. The flange pitch diameter, number of holes and hole size are as standard in accordance with EUROVENT Mounting positions are in accordance with EUROV- ENT for ACG - arrangement B, motor position A. See also section "Calculations" page 26. The motor is a flange motor with electrical connection The direction of air flow for ACG is motor - vane. The ACP range of axial fans comprises 14 installation sizes with rotor diameters from 0250 to 01600 mm for standard fans and 12 installation sizes with rotor There are seven hub diameter...

 Open the catalog to page 7
ACN-8

Overview of Types and Accessories Please note the combinations of motors and fans are Novenco or through use of the Novax calculation pro- general. Precise combinations of motors from specific gram found on www.novenco.biz/productmanager. suppliers and fans are available on request to

 Open the catalog to page 8
ACN-9

Rotor Diameters fmrn M'M-t'M BBH W:LW<W ■-.(-■«■■ W:IM<W ■ôT^Ti» U'.iibM W:M<m g-.H'M f-.t [■!■!■! IstlHil r*tt*ftl löIEIïTïl lotEMil 1. Hot smoke fans with hub diameter 0403, motor size 180 and rotor diameter 0900 are only made as type ACP. All versions ; ° = Limited number of versions Accessories for standard and hot Smoke Fans 1. A standard clip is used for joining of two silencers type YAH. It is inadvisable to join more than two silencers with standard clips. 2. The number of versions where brass lining is possible is among others limited by the blade angle. What versions are offered with...

 Open the catalog to page 9
ACN-10

The diagrams indicate the coverage for each of the fan sizes without taking the hub diameter into consider- The capacities are based on fan installation in accord- ance with BS 848 1980, installation type D (duct con- nection for inlet and outlet). Other installation types yield other data. The air density is p = 1.20 kg/m . Final dimensioning, including calculation of blade angles, choice of motor, power consumption plus sound calculation, is done on Novenco's web site. See section "Internet Calculation Program" page 4.

 Open the catalog to page 10
ACN-11

Air Flow Rate, qv [rn^/s] Air Flow Rate, qv [rn^/s]

 Open the catalog to page 11
ACN-12

The diagrams indicate the coverage for each of the fan sizes without taking the hub diameter into consider- The capacities are based on fan installation in accord- ance with BS 848 1980, installation type B (free inlet and duct connection for outlet). Other installation types yield other data. The air density is p = 1.20 kg/ Final dimensioning, including calculation of blade angles, choice of motor, power consumption plus sound calculation, is done on Novenco's web site. See section "Internet Calculation Program" page 4.

 Open the catalog to page 12
ACN-13

Air Flow Rate, qv [rn^/s] Air Flow Rate, qv [rn^/s]

 Open the catalog to page 13
ACN-14

Performance Curves for ACP at 50 Hz types yield other data. The air density is ρ = 1.20 kg/ m3. The diagrams indicate the coverage for each of the fan sizes without taking the hub diameter into consideration. Final dimensioning, including calculation of blade angles, choice of motor, power consumption plus sound calculation, is done on Novenco’s web site. See section “Internet Calculation Program“ page 4. The capacities are based on fan installation in accordance with BS 848 1980, installation type B (free inlet and duct connection for outlet). Other installation 2000 1500 1000 200 900 100 710...

 Open the catalog to page 14

All Novenco catalogs and brochures

  1. NovPac-R

    2  Pages

  2. ZPR

    2  Pages

  3. Super Speed

    2  Pages

  4. workboats

    4  Pages

  5. navy system

    4  Pages

  6. FLEXAIR

    8  Pages

  7. ZerAx axial

    20  Pages

  8. ZCR

    32  Pages

  9. MICROVENT

    8  Pages

  10. CND and CNF

    24  Pages

  11. MICRO VENT

    8  Pages

  12. NOVPAC R

    2  Pages

  13. CNA-CNB

    20  Pages

Archived catalogs

  1. Navy System 1

    4  Pages

  2. CAL

    40  Pages

  3. VMA-VMB

    24  Pages

  4. SJD

    12  Pages

  5. ZCP

    36  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.