video corpo

ACN
28Pages

{{requestButtons}}

Catalog excerpts

ACN - 1

Novenco Axial Flow Fans Novax — Standard and hot Smoke September 2006

Open the catalog to page 1
ACN - 2

Product Facts Axial flow fans with presettable • ACG free intake with connec- Novax axial flow fans are used for standard installations in connec- tion with comfort and industrial ventilation including removal of hot smoke in case of fire. The series of Novax axial fans is of- fered in 14 sizes with rotor diame- standard fans and in 12 sizes with rotor diameters from 0400 to There are seven sizes of hub diam- both types of fans. The air flow rates run from 0.1 to 65 m /s with increases in pressure from 0.2 to 65 m /s with increases smoke fans. Motor Sizes Number of Blades according to Hub...

Open the catalog to page 2
ACN - 3

Type Descriptions Overview of Types and Accessories This document is provided 'As is' and is subject to change without notice. Novenco reserves this right due to continuous product de- Novenco is a trademark of Novenco. Other trademarks appearing in this document are the property of their respective owners.

Open the catalog to page 3
ACN - 4

Novax are compact, robust, series-produced axial flow fans with presettable blades. Novax fans are installed in a wide range of ventilation systems on shore and off-shore: Comfort systems, in- dustrial, process, parking and tunnel ventilation as well as environment-enhancement systems. The fans require little space, are easy to install and offer high operational reliability. The Novax rotor consists of a pressed, two-part, as- sembled hub with depressions in which the blades are fixed. The rotor is provided with a hub boss on one side for mounting on a motor. The rotor blades can be fixed...

Open the catalog to page 4
ACN - 5

The fans are supplied with 50 Hz motors as standard, but can also be supplied with 60 Hz motors. Alterna- tively, they can also be speed controlled by means of frequency inversion with the maximum speeds indi- cated in the table below. Nominal RPMs for 50 Hz motors are found in the per- formance curves on pages 10 through 15. Thus Novax fans are a serious alternative to centrifu- gal fans in ventilation and air conditioning systems with varying air flow rate requirements. Using frequency inverters removes the limitations Thus axial fans can virtually always be placed within the maximum...

Open the catalog to page 5
ACN - 6

Type Descriptions The ACN range of axial fans comprises 14 installation sizes with rotor diameters from 0250 to 01600 mm for standard fans and 12 installation sizes with rotor There are seven hub diameter sizes from 0160 to Air flow rates run from 0.1 to 65 m3/s and pressure in- creases up to 2000 Pa for standard fans and from 0.2 to 65 m /s with pressure increases up to 1800 Pa for As hot smoke fans the range is F300 and F400 ap- proved according to EN 12101-3 to run for at least The fan housing is cylindrical with connection flanges The fan housing has a welded motor mount of sheet steel...

Open the catalog to page 6
ACN - 7

let side of the rotor, enabling the ACG to achieve a very high efficiency. The flange pitch diameter, number of holes and hole size are as standard in accordance with EUROVENT Mounting positions are in accordance with EUROV- ENT for ACG - arrangement B, motor position A. See also section "Calculations" page 26. The motor is a flange motor with electrical connection The direction of air flow for ACG is motor - vane. The ACP range of axial fans comprises 14 installation sizes with rotor diameters from 0250 to 01600 mm for standard fans and 12 installation sizes with rotor There are seven hub...

Open the catalog to page 7
ACN - 8

Overview of Types and Accessories Please note the combinations of motors and fans are Novenco or through use of the Novax calculation pro- general. Precise combinations of motors from specific gram found on www.novenco.biz/productmanager. suppliers and fans are available on request to

Open the catalog to page 8
ACN - 9

Rotor Diameters fmrn M'M-t'M BBH W:LW<W ■-.(-■«■■ W:IM<W ■ôT^Ti» U'.iibM W:M<m g-.H'M f-.t [■!■!■! IstlHil r*tt*ftl löIEIïTïl lotEMil 1. Hot smoke fans with hub diameter 0403, motor size 180 and rotor diameter 0900 are only made as type ACP. All versions ; ° = Limited number of versions Accessories for standard and hot Smoke Fans 1. A standard clip is used for joining of two silencers type YAH. It is inadvisable to join more than two silencers with standard clips. 2. The number of versions where brass lining is possible is among others limited by the blade angle. What versions are offered...

Open the catalog to page 9
ACN - 10

The diagrams indicate the coverage for each of the fan sizes without taking the hub diameter into consider- The capacities are based on fan installation in accord- ance with BS 848 1980, installation type D (duct con- nection for inlet and outlet). Other installation types yield other data. The air density is p = 1.20 kg/m . Final dimensioning, including calculation of blade angles, choice of motor, power consumption plus sound calculation, is done on Novenco's web site. See section "Internet Calculation Program" page 4.

Open the catalog to page 10
ACN - 11

Air Flow Rate, qv [rn^/s] Air Flow Rate, qv [rn^/s]

Open the catalog to page 11
ACN - 12

The diagrams indicate the coverage for each of the fan sizes without taking the hub diameter into consider- The capacities are based on fan installation in accord- ance with BS 848 1980, installation type B (free inlet and duct connection for outlet). Other installation types yield other data. The air density is p = 1.20 kg/ Final dimensioning, including calculation of blade angles, choice of motor, power consumption plus sound calculation, is done on Novenco's web site. See section "Internet Calculation Program" page 4.

Open the catalog to page 12
ACN - 13

Air Flow Rate, qv [rn^/s] Air Flow Rate, qv [rn^/s]

Open the catalog to page 13
ACN - 14

Performance Curves for ACP at 50 Hz types yield other data. The air density is ρ = 1.20 kg/ m3. The diagrams indicate the coverage for each of the fan sizes without taking the hub diameter into consideration. Final dimensioning, including calculation of blade angles, choice of motor, power consumption plus sound calculation, is done on Novenco’s web site. See section “Internet Calculation Program“ page 4. The capacities are based on fan installation in accordance with BS 848 1980, installation type B (free inlet and duct connection for outlet). Other installation 2000 1500 1000 200 900 100...

Open the catalog to page 14

All Novenco catalogs and brochures

  1. NovPac-R

    2 Pages

  2. ZPR

    2 Pages

  3. Super Speed

    2 Pages

  4. workboats

    4 Pages

  5. navy system

    4 Pages

  6. FLEXAIR

    8 Pages

  7. ZerAx axial

    20 Pages

  8. ZCR

    32 Pages

  9. MICROVENT

    8 Pages

  10. CND and CNF

    24 Pages

  11. MICRO VENT

    8 Pages

  12. NOVPAC R

    2 Pages

  13. CNA-CNB

    20 Pages

Archived catalogs

  1. CAL

    40 Pages

  2. VMA-VMB

    24 Pages

  3. SJD

    12 Pages

  4. ZCP

    36 Pages