System Concept
The NORIMOS 3500 (N3500) is a cost-effective, computer-based alarm, monitoring, and control system designed for ship technology management. It centralizes operations through two PC master stations that monitor data from connected I/O modules, supporting up to 9,000 I/Os. The system is adaptable to customer needs and includes features like trend tables and automatic alarm history storage. Optional alarm extensions provide system status displays throughout the ship.
Secure Redundant System Communication
The N3500 ensures maximum availability through redundant communication via CANbus and Ethernet. All components are designed redundantly, allowing continued operation even if individual components fail.
Key Benefits
  • Central and modular system, easily expandable
  • Cost-effective with standardized components
  • Redundant communication for reliability
  • Designed for extreme conditions
  • Customizable displays for bridge and accommodation
  • Worldwide service and class approval (BV, ABS, DNV-GL, CCS)
System Features
The system includes two PC master stations operating in hot standby mode, acquiring and monitoring data from signal acquisition units (SAUs). It supports graphical and numerical mimics, alarm lists, and measuring parameter lists. Communication is secured via Ethernet and CANbus, allowing easy system extension.
Application Suitability
  • Data acquisition and recording
  • Engine alarm and monitoring
  • Control of bilge, ballast, and auxiliary systems
Alarm Extension and Visualisation
Features high-resolution displays for various ship areas, duty assignment for unmanned machinery spaces, and an intuitive GUI with customizable graphical displays.
Other System Features
  • Customizable measuring parameters
  • Alarm history storage and printing
  • User access levels for security
System Extension
The system can be extended via Ethernet to include additional PCs, displays, and printers. It supports alarm extensions for accommodation and engine control rooms, adaptable to class rules for unmanned machinery spaces.
I/O Units
Each I/O unit includes microcomputers and interfaces for signal processing, supporting various input types like binary channels and sensors.
NORINET for Secure Data Transfer
NORINET provides secure data transfer and remote access, essential for maintenance and predictive analysis. It supports real-time access, data logging, and trend analysis, enhancing maintenance processes and ensuring failsafe operation.
See more

Catalog excerpts

Flyer NORIMOS 3500 - Computer-based Alarm, Monitoring and Control System-1

Computer-based Alarm, Monitoring and Control System The system concept Your benefits at a glance The N3500 is our solution for a cost-effective alarm, monitoring and control system of ■■Central and modular system, easily the well-known NORIMOS family. It is used to monitor and control ship technology, such expandable for your application as engines, generators, pumps, valves, ventilators or other auxiliary system. The N3500 as a centralised system is based on two central PC master stations that are acquiring and with standardised functionality monitoring the measurement data from the connected I/O modules. It can be easily extended to customer requirements. With up to 9,000 I/Os and features like trend tables and automatic and daily storage of the alarm history on hard disk, the system leaves sufficient space for different applications and thus, it is ideally suitable for both small data ■■Redundant system communication ■■Made for reliable operation under extreme conditions ■■Powerful alarm extension system: acquisition systems and complex alarm, monitoring and control systems. The optional High-resolution displays for deman- alarm extension indicates the system status at any place on board the ship. Therefore, ding graphical indication for bridge different display versions for accommodation and bridge are available. Secure redundant system communication The redundant communication via CANbus and Ethernet ensures maximum system availability. All system components are designed redundantly and even in case of failure ■■Customisable mimics ■■Worldwide service ■■Class approval: BV, ABS, DNV-GL, CCS (others on request) of single components, the system can still be operated. Alarm and Display Unit N3520 an

 Open the catalog to page 1
Flyer NORIMOS 3500 - Computer-based Alarm, Monitoring and Control System-2

NORIMOS 3500 system features N3500 system overview Chief Eng. Room Mess Room Alarm Extension and Duty Assignment ■■Measurement data acquisition and data recording ■■Engine alarm and monitoring ■■Engine start / stop ■■Control and monitoring of bilge and ballast system ■■Control of other auxialiary systems ■■7” high-resolution display and 5.7” alarm extension display ■■Modern and uniform look & feel ■■Easy-to-customise graphical colour mimic display ■■Intuitive, clear and easy to understand GUI ■■Measuring parameter list, alarm list, alarm history and CPU 1 ■■Duty assignment and duty takeover for...

 Open the catalog to page 2
Flyer NORIMOS 3500 - Computer-based Alarm, Monitoring and Control System-3

NORINET for secure data transfer and remote access Your benefits at a glance ■■Optional remote access available System maintenance is essential in order to minimise service and repair costs and to keep all systems on board running. We have the right solution that avoids idle time in ■■Flexibility for the ship owner and his ports and enables us to react flexibly and fast. The optional remote access and the long time storage of engine and monitoring system data are further essential factors con- ■■Enables system secure remote access ■■Realtime access to monitoring system ■■Optimises maintenance...

 Open the catalog to page 3

All NORIS Group GmbH catalogs and brochures

  1. Datasheet RG5

    2  Pages

  2. Datasheet FA13

    14  Pages

  3. Datasheet NIQ31

    16  Pages

  4. Datasheet FA54

    11  Pages

  5. NORIS Brochure

    15  Pages

  6. Datasheet EOT

    6  Pages

  7. Datasheet DWA

    4  Pages

  8. Datasheet VF5

    2  Pages

  9. Datasheet RF5

    2  Pages

  10. Datasheet RI5

    2  Pages

  11. Datasheet RH5

    2  Pages

  12. Datasheet RW5

    2  Pages

  13. Datasheet VP5

    2  Pages

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.