Group: Noris Group
Catalog excerpts
Measuring transducer for temperature, input Pt100/Pt1000 with two-wire-circuit 1 2 Straightforward application Suitable for severe operating conditions Compact construction Galvanic isolation between sensor input and Umgeb. Amb. Temp Temp: : output signal to the operating voltage • Anti-tamper seal for the fine adjustment Provision made for fine adjustment of measuring range Measuring Transducers Meet high EMC-requirements requirements Short-circuit-proof output selectable from 0 ... 10 V/DC, 2 ... 10 V/DC, 0 ... 20 mA, 4 ... 20 mA Broken-wire monitoring of input signal Operating characteristics displayed by integrated LED Flame-inhibiting and self-extinguishing body Short-circuit monitoring of input signal Suitable temperature sensors are available (NORIS-type TP.1, TP.2, TP.3) Measuring transducers of series 5 Measuring transducers of the Series 5 are designed to convert electric input values into standardised output signals. Principle of operation: The transducer signal measured at the converter input is converted into a standardised output signal that is proportional to the input and lends itself to further customised processing, for instance, in a machine controller. General notes on Type VP5.., VPT5.. Description VP5.., VPT5.. Output signal The measuring transducers VP5.. and VPT5.. are designed to The output signal generated is a standardized voltage of evaluate the temperature with platinum Pt100 RTD (VP5..) or Pt1000 0 ... 10 V/DC or 2 ... 10 V/DC, respectively, a standardized current of RTD (VPT5..) according to EN60751 Class B in two-wire circuit. A 0 ... 20 mA or 4 ... 40 mA. The output signal follows the input signal platinum resistor has a positive temperature coefficient which means that the resistance increases as the temperature rises. Access is provided to a trimming potentiometer to permit a line compensation to be applied for Pt100 RTD measuring transducers. The output signal can be used to supply additional devices, such as indicating instruments and limit-value switches. Point to be noted: the maximum driver capability of the output. Pt1000 RTDs do not require such compensation because, in principle, line resistance can be neglected. For better adaption to the required measuring task four measuring ranges are prepared: -30 ... +120 °C, 0 ... 120 °C, 0 ... 150 °C, 0 ... 200 °C. Monitoring for integrity and short circuit The devices are designed with sensor monitored for discontinuity and short circuit. In the event of any fault, the output signal setting is 22 mA or, respectively, 11.5 V. Electric isolation Sensor input and output signals are electrically isolated from Operating status display by LED the operating voltage. Multiple operation of amplifiers and evaluation The green LED will be lit when the operating voltage is applied devices is therefore possible at the same operating voltage. The and the device is working normally and also when a broken wire sensor only supplies one amplifier device. occurs, it will be flashing in case of short circuit. In addition triggers a broken wire und
Open the catalog to page 1Other Data Series VP5.., VPT5.. Type key / variants LED code Input range: Device codes Measuring transducer Type series 5 Type 5
Open the catalog to page 2All NORIS Group GmbH catalogs and brochures
-
Unique Yacht Automation
16 Pages
-
Energy storage solutions
2 Pages
-
Datasheet TAV131
3 Pages
-
Datenblatt VFS5
2 Pages
-
Datasheet PAx9
6 Pages
-
Datasheet RG5
2 Pages
-
Datasheet VFW5
2 Pages
-
Datasheet RP5, RPT5
2 Pages
-
Datasheet NIR3 NIQ3
20 Pages
-
Datasheet VD61
6 Pages
-
Datasheet FA13
14 Pages
-
Datasheet NIQ31
16 Pages
-
Energy Storage System
2 Pages
-
NORIS Marine Overview
13 Pages
-
Datasheet NORISYS 4 LA4
4 Pages
-
Datasheet NORISYS 4 LS4
4 Pages
-
Datasheet NORISYS 4 LT4
4 Pages
-
Datasheet FA54
11 Pages
-
RETROFIT - modernise your
2 Pages
-
NORIS Brochure
15 Pages
-
Datasheet TP31 TH31
5 Pages
-
Datasheet EOT
6 Pages
-
Datasheet NORISPEED FMN6
2 Pages
-
Datasheet DWA
4 Pages
-
Datasheet TP23
4 Pages
-
Datasheet VF5
2 Pages
-
Flyer NORISYS 4 CPU
2 Pages
-
Datasheet RFW5
2 Pages
-
NORISYS 4 - PLC Deep Sea
2 Pages
-
Datasheet RTK5
2 Pages
-
Datasheet RFJ5
2 Pages
-
Datasheet VTK5
2 Pages
-
Datasheet RF5
2 Pages
-
Datasheet RI5
2 Pages
-
Datasheet RFG5
2 Pages
-
Datasheet VPT5
2 Pages
-
Datasheet RH5
2 Pages
-
Datasheet VFS5
2 Pages
-
Datasheet RH41M
2 Pages
-
Datasheet RW5
2 Pages
-
Datasheet VMP70
3 Pages
-
Datasheet NADS3
2 Pages
-
Datasheet NAD2
2 Pages
-
Datasheet NAD1
2 Pages
-
Flyer NORISYS 4
2 Pages
Archived catalogs
-
Datasheet GE12
2 Pages
-
Datasheet GE14
2 Pages