Datasheet VF5
2Pages

{{requestButtons}}

Catalog excerpts

Datasheet VF5 - 1

Measuring transducer for frequency, input NORIS standard signal 1 2 • Straightforward application • Galvanic isolation between sensor input and Umgeb. Amb. Temp Temp: : and operating voltage to the output signal Measuring Transducers • Suitable for severe operating conditions • Compact construction • Frequency ranges to suit customer requirements • Provision made for fine adjustment of measuring range • Anti-tamper seal for the fine adjustment • Meet high EMC-requirements • Short-circuit-proof output selectable from • Operating characteristics displayed by integrated LED • Flame-inhibiting and self-extinguishing body • Suitable speed sensors are available Measuring transducers of series 5 Measuring transducers of the Series 5 are designed to convert electric input values into standardised output signals. Principle of operation: The transducer signal measured at the converter input is converted into a standardised output signal that is proportional to the input and lends itself to further customised processing, for instance, in a machine controller. General notes on Type VF5.. Description VF5.. • Signal input for a NORIS standard frequency signal Input signal The NORIS standard signal corresponds to a rectangular voltage with • Suitable to evaluate sensors of the FT.. and FA.. series an amplitude that corresponds to • Input range: 0 ... 10.000 Hz (according to type) the operating voltage applied. This • Maximum range frequency between: 50 ... 100 Hz (VF500..), results in a signal that is immune to interference and tolerates consider- (Factory-set frequency adjustment) able changes in the operating volt- To avoid triggering errors the frequency full range set in factory must be the highest frequency of the measuring chaine. age. The operating voltage required by the sensor is provided by the measuring transducer. Electric isolation The operating voltage and sensor input are electrically isolated from the output signal. Therefore, multiple operation of amplifiers and evaluation devices is possible at the same operating voltage and from only one sensor. Operating status display by LED The green LED will be lit when the operating voltage is applied and the device is working normally. Output signal The output signal generated is a standardized voltage of 0 ... 10 V/DC or 2 ... 10 V/DC or, respectively, a standardized current of 0 ... 20 mA or 4 ... 20 mA. The output signal follows the input signal strictly linearly (deviation < 0.1%). The output signal can be used to supply additional devices, such as indicating instruments and limit-value switches. Attention should be paid to the maximum driver ca

Open the catalog to page 1
Datasheet VF5 - 2

Other Data Type key / variants LED code x = LED lighting - = LED out o= LED flashing OPerating x Frequency version: Please state upper range frequency in case of order Device codes (10 V/DC or 20 mA meets the ordered input frequency) - ... Maximum range frequency in Hz (= 20 mA or 10 V) Measuring transducer Input signal F Frequency input for NORIS standard signal (sensor series FT / FA) Type series 5 Type 5 Input range fB / upper-range frequency fE Maximum range frequency

Open the catalog to page 2

All NORIS Group GmbH catalogs and brochures

  1. Datasheet FA13

    14 Pages

  2. Datasheet FA54

    11 Pages

  3. NORIS Brochure

    15 Pages

Archived catalogs